Cause:
- ResultsWriter required a generic way to generate customer-specific XML result data from TBF measurement results.
- The customer reference XML contains example runtime values and repeated result structures, so it cannot be used directly as the generated output.
- TBF result variables must be explicitly mapped to destinations in the customer XML structure.
- The generated XML result data must support two output targets:
- direct creation of an XML file,
- delivery of the XML payload to a Microsoft SQL stored procedure.
- Preview generation must allow the XML structure and configured mappings to be verified without executing the production database write.
- Increase revision to 3.9.3145.100.
Solution:
1. Added XML reference analysis
- Creates a clean base XML structure.
- Extracts the repeating result prototype.
- Prevents sample runtime values from the customer reference XML from leaking into generated results.
2. Added configurable TBF-to-XML result mapping
- Allows explicit mapping of TBF result variables to customer XML destinations.
- Supports one-time and repeating XML destinations.
- Keeps the mapping independent of the semantic meaning of customer XML attribute names.
3. Added XML destination viewer and configurator
- Shows the current mapping.
- Highlights repeating destinations.
- Identifies already used one-time destinations.
4. Added runtime XML result generation
- Uses the configured TBF-to-XML mappings.
- Uses measurement procedure result data.
- Builds the output from the clean base XML and repeating XML prototype.
- Generates repeated result records according to the executed measurement procedure.
5. Added simulation-based Preview request
- Generates a complete XML payload using simulation values.
- Allows XML structure and mapping verification before production execution.
- Does not execute the production stored procedure.
6. Added direct XML file output support to UniDataStorageWriter
- Supports File / .xml as a physical output target.
- Creates the generated XML result file in the configured output directory.
7. Added Microsoft SQL stored-procedure XML output
- Supports Microsoft SQL / StoredProcedure as a physical output target.
- Passes the generated XML payload through the configured stored procedure parameter.
8. Added optional XML payload archiving
- Allows generated XML payloads to be stored in the configured Payload archive.
- Can be used together with the Microsoft SQL stored-procedure output.
9. Kept ResultsWriter independent of the physical output target
- ResultsWriter generates the result payload.
- UniDataStorageWriter decides how and where the payload is physically written.
- The same ResultsWriter XML generation mechanism is therefore used for both XML file and MSSQL outputs.
10. Increased revision
- Updated revision to 3.9.3145.100.
Cause:
1. Background: Restore/ensure testInProgress behavior before the DataEntry sequence and explicitly prevent to reset the pulse.
2. Increase revision to 3.9.3145
Solution:
1. Deleted .AddOperation(testInProgress) calling
2. Increased revision to 3.9.3145
Cause:
1. When the Cycle was stopped during the second or a later test and then resumed using the Start Test button, the resume confirmation was handled incorrectly. After selecting to continue, the sequence restarted from the first test instead of continuing from the interrupted test.
2. Increase revision to 3.9.3134.114
Solution:
1. Corrected the Cycle resume logic so that, after confirming continuation, the sequence resumes from the interrupted test instead of restarting from the first test.
2. Increased revision to 3.9.3134.114
Cause:
1. Background: there was a suspicion that the Bukoven board left RefPulses active across operations; this was investigated and ruled out. The pulse counter is reset by testInProgress when an operation is reused. During the third DataEntry window testInProgress had been temporarily disabled (SLM vs Karlsruhe difference), which allowed RefPulses to appear to persist.
2. Increase revision to 3.9.3134.113
Solution:
1. Restore/ensure testInProgress behavior during the DataEntry sequence and explicitly reset the pulse counter when starting a new operation.
2. Increased revision to 3.9.3134.113
Cause:
1. Background: there was a suspicion that the Bukoven board left RefPulses active across operations; this was investigated and ruled out. The pulse counter is reset by testInProgress when an operation is reused. During the third DataEntry window testInProgress had been temporarily disabled (SLM vs Karlsruhe difference), which allowed RefPulses to appear to persist.
2. Increase revision to 3.9.3134.112
Solution:
1. Restore/ensure testInProgress behavior during the DataEntry sequence and explicitly reset the pulse counter when starting a new operation.
2. Increased revision to 3.9.3134.112
Cause:
1. Unnecessary and mandatory user verification before the test, in addition, a bug appears: the "Approval by legalizer" window is displayed behind the main application window. The window was only needed for the Polish project.
2. `LANG_PL` constant in `TBF.csproj` was no longer needed.
3. Assembly version and file version in `AssemblyInfo.cs` needed to be incremented to `3.9.3134.111`.
Solution:
1. Made `altProcNameLabel` and `altProcNameTextBox` always visible and disabled specific UI controls in `ProcedureDlg.cs`.
2. Removed `LANG_PL` from `DefineConstants` in `TBF.csproj`.
3. Updated assembly version and file version in `AssemblyInfo.cs` to `3.9.3134.111`.
Cause:
1. Missing functionality to display remaining time during tests in `StandingStartMassCollectionSeq.cs` and `StandingStartMassCollectionAdvanceSeq.cs`.
2. Assembly version and file version required an update to reflect changes.
Solution:
1. Implemented remaining time display in `StandingStartMassCollectionSeq.cs` and `StandingStartMassCollectionAdvanceSeq.cs` using `Bridge.OnActivity` to show time in minutes and seconds or seconds only.
2. Updated assembly version and file version in `AssemblyInfo.cs` to `3.9.3134.110`.
Cause:
1. Updated `unit` constant in `TestStartEndForm` class within `TBF.Rig.DataEntry.StandardCamera` namespace from `Unit.m3` to `Unit.l`.
2. Updated `unit` constant in `TestStartEndForm` class within `TBF.Rig.DataEntry.StandartCameraPurchaseOrder` namespace from `Unit.m3` to `Unit.l`.
3. Incremented assembly version and file version in `AssemblyInfo.cs` to `3.9.3134.109`.
Solution:
1. Changed `unit` constant in `TestStartEndForm` class within `TBF.Rig.DataEntry.StandardCamera` namespace to `Unit.l`.
2. Changed `unit` constant in `TestStartEndForm` class within `TBF.Rig.DataEntry.StandartCameraPurchaseOrder` namespace to `Unit.l`.
3. Updated assembly version and file version in `AssemblyInfo.cs` to `3.9.3134.109`.
- generate available units using Units.IsQuantity(...)
- use Quantity.MultiFunctionalVariables to populate supported units
- centralize unit selection through Units.GetQuantity()
- Store the value as the default PumpPower for subsequent test instances in the cycle.
- Add logging when PumpPower is initialized from the pump.
- Add logging at test start including test name, repetition number,
last repetition flag, and PumpPower to improve diagnostics.
- Store the value as the default PumpPower for subsequent test instances in the cycle.
- Add logging when PumpPower is initialized from the pump.
- Add logging at test start including test name, repetition number,
last repetition flag, and PumpPower to improve diagnostics.
- When STOP is pressed during PerformSteps() in the BeforeTest transition,
Transition() returned immediately and skipped the common shutdown logic.
This caused FM pumps and valves to remain in their previous state.
- Perform the required safe shutdown (FM pump off and default valve setup)
before returning UiCmdStop or Error.
- Added Underload measurement state
- Detect underload responses from Mettler Toledo scales
- Automatically zero the scale after underload detection
- Restart mass measurement after successful zeroing
- Prevent zeroing response from being used as a valid measurement
- Preserve measurement stability by clearing buffered readings after underload