Cause: 1. When the Cycle was stopped during the second or a later test and then resumed using the Start Test button, the resume confirmation was handled incorrectly. After selecting to continue, the sequence restarted from the first test instead of continuing from the interrupted test. 2. Increase revision to 3.9.3134.114 Solution: 1. Corrected the Cycle resume logic so that, after confirming continuation, the sequence resumes from the interrupted test instead of restarting from the first test. 2. Increased revision to 3.9.3134.114