marekf 37c89a4c9c Fix - missing safe shutdown when PerformSteps returns UiCmdStop
- When STOP is pressed during PerformSteps() in the BeforeTest transition,
Transition() returned immediately and skipped the common shutdown logic.
This caused FM pumps and valves to remain in their previous state.
- Perform the required safe shutdown (FM pump off and default valve setup)
before returning UiCmdStop or Error.