Route handling rewritten, the order of StopDevice( ) calls reversed.
This commit is contained in:
parent
d7e65ff04b
commit
be9d912489
@ -183,7 +183,7 @@ namespace Dirichlet.Numerics
|
||||
|
||||
public override string ToString()
|
||||
{
|
||||
return ((BigInteger)this).ToString();
|
||||
return ((BigInteger)this).ToString("x");
|
||||
}
|
||||
|
||||
public string ToString(string format)
|
||||
|
||||
@ -15,7 +15,7 @@ namespace TBF.Rig.BuiltIn
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(SetValvesOp));
|
||||
|
||||
/// Set by the constructor
|
||||
IControlBoard controlBoard;
|
||||
IControlBoard cb;
|
||||
|
||||
class SwitchPoint
|
||||
{
|
||||
@ -183,8 +183,8 @@ namespace TBF.Rig.BuiltIn
|
||||
/// <remarks>Only Elde.Valve valves are used, other valves on the lists are ignored</remarks>
|
||||
public SetValvesOp(IControlBoard cb, IList<IValve> valvesOpen, IList<IValve> valvesClose)
|
||||
{
|
||||
controlBoard = cb;
|
||||
if (controlBoard == null) throw new ArgumentNullException("ctrlBoard");
|
||||
this.cb = cb;
|
||||
if (this.cb == null) throw new ArgumentNullException("ctrlBoard");
|
||||
|
||||
if (valvesOpen == null) valvesOpen = new List<IValve>();
|
||||
if (valvesClose == null) valvesClose = new List<IValve>();
|
||||
@ -219,8 +219,8 @@ namespace TBF.Rig.BuiltIn
|
||||
/// <remarks>Only Elde.Valve valves are used, other valves on the lists are ignored</remarks>
|
||||
public SetValvesOp(IControlBoard cb, bool open, OutputPath outPath)
|
||||
{
|
||||
controlBoard = cb;
|
||||
if (controlBoard == null) throw new ArgumentNullException("ctrlBoard");
|
||||
this.cb = cb;
|
||||
if (this.cb == null) throw new ArgumentNullException("ctrlBoard");
|
||||
|
||||
IList<IValve> none = new List<IValve>(); /// An empty list of valves
|
||||
switchPointsRaw = new List<SwitchPoint>();
|
||||
@ -280,7 +280,7 @@ namespace TBF.Rig.BuiltIn
|
||||
/// <summary>Start this operation</summary>
|
||||
public void Start()
|
||||
{
|
||||
UInt128 changed = controlBoard.SetValves(switchPoints[0].MasksOpen, switchPoints[0].MasksClose, StateMachine.ExtendedValves);
|
||||
UInt128 changed = cb.SetValves(switchPoints[0].MasksOpen, switchPoints[0].MasksClose, StateMachine.LogicalFnValves);
|
||||
swStartTime = StateMachine.Time;
|
||||
maxDelayTime = switchPoints[0].MaxDelay(changed);
|
||||
nextIx = 1;
|
||||
@ -299,7 +299,7 @@ namespace TBF.Rig.BuiltIn
|
||||
|
||||
if (StateMachine.Time >= swStartTime + switchPoints[nextIx].TimeSec)
|
||||
{
|
||||
UInt128 changed = controlBoard.SetValves(switchPoints[nextIx].MasksOpen, switchPoints[nextIx].MasksClose, StateMachine.ExtendedValves);
|
||||
UInt128 changed = cb.SetValves(switchPoints[nextIx].MasksOpen, switchPoints[nextIx].MasksClose, StateMachine.LogicalFnValves);
|
||||
|
||||
int nextDelay = switchPoints[nextIx].MaxDelay(changed);
|
||||
if (switchPoints[nextIx].TimeSec + nextDelay > maxDelayTime)
|
||||
|
||||
@ -59,9 +59,10 @@ namespace TBF.Rig.BuiltIn
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Process the list of components and return extended valves
|
||||
/// Process the list of components and return logical function valves
|
||||
/// (their state is calculated from states of other valves).
|
||||
/// </summary>
|
||||
public static IList<BuiltIn.ValveEx.Valve> ExtendedValves(IList<Generic.IComponent> cmpnts)
|
||||
public static IList<BuiltIn.ValveEx.Valve> LogicalFnValves(IList<Generic.IComponent> cmpnts)
|
||||
{
|
||||
IList<BuiltIn.ValveEx.Valve> result = new List<BuiltIn.ValveEx.Valve>();
|
||||
foreach (var cmpnt in cmpnts)
|
||||
|
||||
@ -15,7 +15,7 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
public const int PayloadLen = 38;
|
||||
public const byte MessageCode = (byte)' ';
|
||||
|
||||
public static byte[] GetMessage(Action action, short config)
|
||||
public static byte[] GetMessage(Action action, short config, ulong bitsToInvert)
|
||||
{
|
||||
byte[] message = new byte[PayloadLen + 5]; /// headed 3 bytes, checksum 2 bytes
|
||||
|
||||
@ -46,15 +46,16 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
message[15] = (byte)((config >> 8) & 0xff);
|
||||
|
||||
/// Route
|
||||
ulong routeOut = action.Route ^ bitsToInvert;
|
||||
message[16] = ((action.ActionId & ActionID.ChangeRoute) != 0) ? (byte)1 : (byte)0; /// Route change flag
|
||||
message[17] = (byte)(action.Route & 0xFF);
|
||||
message[18] = (byte)((action.Route >> 8) & 0xFF);
|
||||
message[19] = (byte)((action.Route >> 16) & 0xFF);
|
||||
message[20] = (byte)((action.Route >> 24) & 0xFF);
|
||||
message[21] = (byte)((action.Route >> 32) & 0xFF);
|
||||
message[22] = (byte)((action.Route >> 40) & 0xFF);
|
||||
message[23] = (byte)((action.Route >> 48) & 0xFF);
|
||||
message[24] = (byte)((action.Route >> 56) & 0xFF);
|
||||
message[17] = (byte)(routeOut & 0xFF);
|
||||
message[18] = (byte)((routeOut >> 8) & 0xFF);
|
||||
message[19] = (byte)((routeOut >> 16) & 0xFF);
|
||||
message[20] = (byte)((routeOut >> 24) & 0xFF);
|
||||
message[21] = (byte)((routeOut >> 32) & 0xFF);
|
||||
message[22] = (byte)((routeOut >> 40) & 0xFF);
|
||||
message[23] = (byte)((routeOut >> 48) & 0xFF);
|
||||
message[24] = (byte)((routeOut >> 56) & 0xFF);
|
||||
|
||||
/// DA2
|
||||
message[25] = 0;
|
||||
|
||||
@ -83,14 +83,32 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
int rcvdBytesCount; /// Count of valid bytes in rcvdData buffer
|
||||
|
||||
///
|
||||
/// Digital outputs, states of electromagnetic valves
|
||||
/// Route / digital outputs / states of electromagnetic valves
|
||||
///
|
||||
readonly UInt128 routeMask; /// Set in the constructor, bits of outputs that can be controlled by Action.ChangeRoute are set.
|
||||
/// Regulation valve control outputs and diverters cannot be controlled by Action.ChangeRoute
|
||||
/// Depends on the control board configuration
|
||||
|
||||
ulong valvesToInvert; /// From configurations of valve and pump components. Inversion is applied when creating
|
||||
/// Action.ChangeRoute an dafter obtaining RRoute from the control board
|
||||
|
||||
/// State of digital outputs obtained from the control board
|
||||
public UInt128 RRoute { get { return (UInt128)Data.Vystupy ^ valvesToInvert; } }
|
||||
|
||||
UInt128 displayedRoute; /// A route displayed on the screen (inversions are not applied)
|
||||
UInt128 bitsChangedByUI; /// Ones in this word indicate which valves/pumpes were changed in UI by mouse clicks
|
||||
UInt128 displayedRoutePlusUI; /// A route displayed on the screen plus the modifications from UI (inversions are not applied)
|
||||
UInt128 outputLatch; /// A copy of route sent to physical outputs
|
||||
UInt128 benchModelRoute;
|
||||
UInt128 valvesToInvert; /// Propagated from configurations of other components
|
||||
readonly UInt128 routeMask; /// This mask masks out virtual valves, routeMask is set in the constructor
|
||||
bool outputsInitialized;
|
||||
int lastStateMachineTime = 0;
|
||||
|
||||
/// <summary>
|
||||
/// Route: 128-bit word representing the current state of all valves and pumps
|
||||
/// </summary>
|
||||
public UInt128 Route { get { return benchModelRoute; } }
|
||||
|
||||
|
||||
/// UI actions are blocked when true
|
||||
public bool IsUIBlocked { get; set; }
|
||||
|
||||
@ -119,12 +137,6 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
return 0;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Route: 128-bit word representing the current state of all valves and pumps
|
||||
/// </summary>
|
||||
public UInt128 Route { get { return benchModelRoute; } }
|
||||
public UInt128 RRoute { get { return (UInt128)Data.Vystupy; } }
|
||||
|
||||
/// Values valid during a test
|
||||
public double RefFrequency { get { return Data.ReferenceFreq[0]; } }
|
||||
public double RefFrequency1 { get { return Data.ReferenceFreq[1]; } }
|
||||
@ -179,14 +191,11 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
scopeAnalyzerData = null;
|
||||
switchCounterData = null;
|
||||
|
||||
routeMask = 0;
|
||||
for (int i = 0; i < 128; i++)
|
||||
{
|
||||
if (i < cbCfg.VirtValvesRangeLo || i > cbCfg.VirtValvesRangeHi)
|
||||
{
|
||||
routeMask = routeMask | ((UInt128)1 << i);
|
||||
}
|
||||
}
|
||||
routeMask = 0xFF00FFFFFF;
|
||||
for (int i = 0; i < cbCfg.RegValvesCount; i++) routeMask &= ~((UInt128)3 << 2*i);
|
||||
if (cbCfg.RelaysFInstalled) routeMask |= 0xFF0000000000;
|
||||
if (cbCfg.RelaysGInstalled) routeMask |= 0xFF000000000000;
|
||||
if (cbCfg.RelaysHInstalled) routeMask |= 0xFF00000000000000;
|
||||
|
||||
log.Warn(this.ToString());
|
||||
}
|
||||
@ -197,8 +206,7 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
/// <param name="valvesToInvert"></param>
|
||||
public void SpecifyInvertedValves(UInt128 valvesToInvert)
|
||||
{
|
||||
this.valvesToInvert = valvesToInvert;
|
||||
this.benchModelRoute = valvesToInvert;
|
||||
this.valvesToInvert = (ulong)valvesToInvert;
|
||||
}
|
||||
|
||||
#region IDevice interface
|
||||
@ -225,17 +233,20 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
serialPort.ParityReplace = 0xFF;
|
||||
serialPort.Open();
|
||||
|
||||
/// Handler handling mouse clicks on the schematc drawinng - valve or pump state changes
|
||||
TBF.UiBridge.Bridge.RouteChangeHandler += delegate(object sndr, TBF.UiBridge.RouteChangeArgs args)
|
||||
{
|
||||
UInt128 mask = ((UInt128)1) << args.BitNr;
|
||||
if ((benchModelRoute & mask) == 0)
|
||||
{
|
||||
benchModelRoute |= mask;
|
||||
}
|
||||
else
|
||||
{
|
||||
benchModelRoute &= (~mask);
|
||||
}
|
||||
UInt128 oneBitMask = ((UInt128)1) << args.BitNr;
|
||||
bitsChangedByUI |= oneBitMask;
|
||||
displayedRoutePlusUI = displayedRoutePlusUI ^ oneBitMask;
|
||||
//if ((displayedRoutePlusUI & oneBitMask) == 0)
|
||||
//{
|
||||
// displayedRoutePlusUI |= oneBitMask;
|
||||
//}
|
||||
//else
|
||||
//{
|
||||
// displayedRoutePlusUI &= (~oneBitMask);
|
||||
//}
|
||||
};
|
||||
|
||||
log.FatalFormat("{0} - Device successfully initialized", Name);
|
||||
@ -329,20 +340,15 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
}
|
||||
rcvdBytesCount -= lastValidOffset;
|
||||
|
||||
/// Synchronize benchModelRoute with RRoute
|
||||
SyncRoute();
|
||||
}
|
||||
benchModelRoute = RRoute;
|
||||
///
|
||||
if (!IsUIBlocked && bitsChangedByUI != 0)
|
||||
{
|
||||
benchModelRoute = (benchModelRoute & ~bitsChangedByUI) | (displayedRoutePlusUI & bitsChangedByUI);
|
||||
bitsChangedByUI = 0;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Set Route to value returned by RRoute. Take virtual valves into account.
|
||||
/// </summary>
|
||||
/// <returns>'ulong' with bits of valves that have changed set to '1'</returns>
|
||||
public UInt128 SyncRoute()
|
||||
{
|
||||
UInt128 oldRoute = benchModelRoute;
|
||||
benchModelRoute = (RRoute & routeMask) | (benchModelRoute & (~routeMask));
|
||||
log.DebugFormat("SyncRoute(), new route = {0}", Utils.RouteToStr(benchModelRoute));
|
||||
return oldRoute ^ benchModelRoute;
|
||||
log.DebugFormat("Route synced with RRoute and UI changes, new route = {0}", Utils.RouteToStr(benchModelRoute));
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
@ -352,6 +358,20 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
if (cbCfg.DebugLevel != DebugMode.Normal) return;
|
||||
|
||||
|
||||
/// Synchronize benchModelRoute with RRoute
|
||||
if (!IsUIBlocked && bitsChangedByUI != 0)
|
||||
{
|
||||
benchModelRoute = (benchModelRoute & ~bitsChangedByUI) | (displayedRoutePlusUI & bitsChangedByUI);
|
||||
bitsChangedByUI = 0;
|
||||
}
|
||||
displayedRoute = Route;
|
||||
displayedRoutePlusUI = Route;
|
||||
bitsChangedByUI = 0;
|
||||
ProcessData.UpdateMeasuredValuesAndSetpoints();
|
||||
Bridge.OnStateMachineTick(this, new StateMachineTickEventArgs(displayedRoute, ProcessData.MsrmntAvailableFlags, ProcessData.MeasuredValues,
|
||||
ProcessData.AltStrings, ProcessData.Setpoints));
|
||||
|
||||
/// Make sure the serial port is open
|
||||
if (serialPort == null || !serialPort.IsOpen)
|
||||
{
|
||||
@ -374,7 +394,7 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
}
|
||||
}
|
||||
|
||||
if (!outputsInitialized || RRoute != benchModelRoute) /// || (StateMachine.Time - lastStateMachineTime) >= 15)
|
||||
if (!outputsInitialized || (outputLatch & routeMask) != (benchModelRoute & routeMask)) /// || (StateMachine.Time - lastStateMachineTime) >= 15)
|
||||
{
|
||||
var actionsToModify = actionQueue.Where(x => (x.ActionId == ActionID.ChangeRoute));
|
||||
bool oneModified = false;
|
||||
@ -394,7 +414,7 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
if (!oneModified)
|
||||
{
|
||||
actionQueue.Enqueue(Action.ChangeRoute(false, (ulong)benchModelRoute));
|
||||
log.InfoFormat("ChangeRoute(route={0:X}) ... a new action enqueued", benchModelRoute);
|
||||
log.InfoFormat("ChangeRoute(route={0:X}) ... a new action enqueued", (ulong)benchModelRoute);
|
||||
}
|
||||
|
||||
foreach (var a in actionQueue) log.DebugFormat(" {0}", a);
|
||||
@ -402,12 +422,13 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
|
||||
|
||||
var combinedAction = Action.FetchNonConflictingActions(actionQueue); /// Default action is RequestDataOnly
|
||||
byte[] outData = OutputMessage.GetMessage(combinedAction, config);
|
||||
byte[] outData = OutputMessage.GetMessage(combinedAction, config, valvesToInvert);
|
||||
if (outData != null && outData.Length > 0)
|
||||
{
|
||||
if ((combinedAction.ActionId & ActionID.ChangeRoute) != 0)
|
||||
{
|
||||
outputsInitialized = true;
|
||||
outputLatch = combinedAction.Route;
|
||||
lastStateMachineTime = StateMachine.Time;
|
||||
}
|
||||
|
||||
@ -417,11 +438,6 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
Debug.WriteLine(s);
|
||||
log.Debug(s);
|
||||
}
|
||||
|
||||
|
||||
ProcessData.UpdateMeasuredValuesAndSetpoints();
|
||||
Bridge.OnStateMachineTick(this, new StateMachineTickEventArgs(Route, ProcessData.MsrmntAvailableFlags, ProcessData.MeasuredValues,
|
||||
ProcessData.AltStrings, ProcessData.Setpoints));
|
||||
}
|
||||
|
||||
public void StopDevice()
|
||||
@ -470,11 +486,18 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
return 0;
|
||||
}
|
||||
|
||||
public UInt128 SetValves(UInt128 valvesToOpen, UInt128 valvesToClose, IList<BuiltIn.ValveEx.Valve> extendedValves)
|
||||
/// <summary>
|
||||
/// Called from Start() and Run() functions of SetValvesOp, i.e. from State.RunOperations().
|
||||
/// </summary>
|
||||
/// <param name="valvesToOpen">Bits of valves to be open are set</param>
|
||||
/// <param name="valvesToClose">Bits of valves to be closed are set</param>
|
||||
/// <param name="logicalFnValves">A list of logical function valves (to be calculated and applied afterwards)</param>
|
||||
/// <returns>Bits of changed valves are set in the return value</returns>
|
||||
public UInt128 SetValves(UInt128 valvesToOpen, UInt128 valvesToClose, IList<BuiltIn.ValveEx.Valve> logicalFnValves)
|
||||
{
|
||||
UInt128 oldRoute = benchModelRoute;
|
||||
benchModelRoute = (((benchModelRoute ^ valvesToInvert) | valvesToOpen) & (~valvesToClose)) ^ valvesToInvert;
|
||||
foreach (var extV in extendedValves) extV.UpdateRoute(ref benchModelRoute);
|
||||
benchModelRoute = (benchModelRoute | valvesToOpen) & (~valvesToClose);
|
||||
foreach (var logFnV in logicalFnValves) logFnV.UpdateRoute(ref benchModelRoute);
|
||||
log.DebugFormat("SetValves(x,x), new route = {0}", Utils.RouteToStr(benchModelRoute));
|
||||
UInt128 retVal = oldRoute ^ benchModelRoute;
|
||||
|
||||
|
||||
@ -6,6 +6,7 @@ using System.Collections.Generic;
|
||||
using System.Xml.Serialization;
|
||||
using Config.Entities;
|
||||
using SchematicDrawing;
|
||||
using TBF.Resources;
|
||||
using TBF.Rig.Generic;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
@ -27,8 +28,9 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
public int DivertersCount;
|
||||
public int DrainValvesCount;
|
||||
public int RegValvesCount;
|
||||
public int VirtValvesRangeLo;
|
||||
public int VirtValvesRangeHi;
|
||||
public bool RelaysFInstalled;
|
||||
public bool RelaysGInstalled;
|
||||
public bool RelaysHInstalled;
|
||||
|
||||
/// Schematic drawing info
|
||||
public Shape Shape { get; set; }
|
||||
@ -77,8 +79,12 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
public void InitializeAll()
|
||||
{
|
||||
ComPortNr = 1;
|
||||
VirtValvesRangeLo = 90;
|
||||
VirtValvesRangeHi = 99;
|
||||
DivertersCount = 3;
|
||||
DrainValvesCount = 4;
|
||||
RegValvesCount = 5;
|
||||
RelaysFInstalled = true;
|
||||
RelaysGInstalled = true;
|
||||
RelaysHInstalled = true;
|
||||
}
|
||||
|
||||
string[] paramNames = new string[]
|
||||
@ -87,23 +93,38 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
"Diverters count (1..5)",
|
||||
"Drain valves count (0..8)",
|
||||
"Regulation valves count (4..8)",
|
||||
"Virtual valves range LO [bit#]",
|
||||
"Virtual valves range HI [bit#]",
|
||||
"Relays F are installed",
|
||||
"Relays G are installed",
|
||||
"Relays H are installed",
|
||||
};
|
||||
public string ParamName(int i) { return paramNames[i]; }
|
||||
public int ParamsCount() { return paramNames.Length; }
|
||||
|
||||
public ICollection<string> ParamValues(int i)
|
||||
{
|
||||
return null;
|
||||
switch (i)
|
||||
{
|
||||
case 1:
|
||||
return new string[] { "1", "2", "3", "4", "5" };
|
||||
case 2:
|
||||
return new string[] { "0", "1", "2", "3", "4", "5", "6", "7", "8" };
|
||||
case 3:
|
||||
return new string[] { "4", "5", "6", "7", "8" };
|
||||
case 4:
|
||||
case 5:
|
||||
case 6:
|
||||
return new string[] { Strings.yes, Strings.no };
|
||||
default:
|
||||
return null;
|
||||
}
|
||||
}
|
||||
|
||||
public string ToString(int i)
|
||||
{
|
||||
if (i == -1)
|
||||
{
|
||||
return string.Format("{0}: COM{1} DIVs={2} VBs={3} RVs={4} VirtVRangeLo={5}, VirtVRangeHi={6}",
|
||||
Name, ComPortNr, DivertersCount, DrainValvesCount, RegValvesCount, VirtValvesRangeLo, VirtValvesRangeHi);
|
||||
return string.Format("{0}: COM{1} DIVs={2} VBs={3} RVs={4} RelaysF={5} RelaysG={6} RelaysH={7}",
|
||||
Name, ComPortNr, DivertersCount, DrainValvesCount, RegValvesCount, RelaysFInstalled, RelaysGInstalled, RelaysHInstalled);
|
||||
}
|
||||
|
||||
switch (i)
|
||||
@ -112,27 +133,29 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
case 1: return DivertersCount.ToString();
|
||||
case 2: return DrainValvesCount.ToString();
|
||||
case 3: return RegValvesCount.ToString();
|
||||
case 4: return VirtValvesRangeLo.ToString();
|
||||
case 5: return VirtValvesRangeHi.ToString();
|
||||
case 4: return RelaysFInstalled ? Strings.yes : Strings.no;
|
||||
case 5: return RelaysGInstalled ? Strings.yes : Strings.no;
|
||||
case 6: return RelaysHInstalled ? Strings.yes : Strings.no;
|
||||
default: return string.Empty;
|
||||
}
|
||||
}
|
||||
|
||||
public CfgUpdateFlags UpdateParam(int i, string strValue)
|
||||
public CfgUpdateFlags UpdateParam(int i, string str)
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 0: ComPortNr = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 1: DivertersCount = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 2: DrainValvesCount = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 3: RegValvesCount = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 4: VirtValvesRangeLo = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 5: VirtValvesRangeHi = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 0: ComPortNr = int.Parse(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 1: DivertersCount = int.Parse(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 2: DrainValvesCount = int.Parse(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 3: RegValvesCount = int.Parse(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 4: RelaysFInstalled = (str == Strings.yes); return CfgUpdateFlags.RestartRqrd;
|
||||
case 5: RelaysGInstalled = (str == Strings.yes); return CfgUpdateFlags.RestartRqrd;
|
||||
case 6: RelaysHInstalled = (str == Strings.yes); return CfgUpdateFlags.RestartRqrd;
|
||||
default: return CfgUpdateFlags.None;
|
||||
}
|
||||
}
|
||||
|
||||
public bool ValidateParam(int i, string strValue, out string message)
|
||||
public bool ValidateParam(int i, string str, out string message)
|
||||
{
|
||||
message = string.Empty;
|
||||
int n;
|
||||
@ -140,20 +163,21 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
switch (i)
|
||||
{
|
||||
case 0:
|
||||
if (int.TryParse(strValue, out n) && (n >= 1)) return true;
|
||||
if (int.TryParse(str, out n) && (n >= 1)) return true;
|
||||
break;
|
||||
case 1:
|
||||
if (int.TryParse(strValue, out n) && (n >= 1) && n <= 5) return true;
|
||||
if (int.TryParse(str, out n) && (n >= 1) && n <= 5) return true;
|
||||
break;
|
||||
case 2:
|
||||
if (int.TryParse(strValue, out n) && (n >= 0) && n <= 8) return true;
|
||||
if (int.TryParse(str, out n) && (n >= 0) && n <= 8) return true;
|
||||
break;
|
||||
case 3:
|
||||
if (int.TryParse(strValue, out n) && (n >= 4) && n <= 8) return true;
|
||||
if (int.TryParse(str, out n) && (n >= 4) && n <= 8) return true;
|
||||
break;
|
||||
case 4:
|
||||
case 5:
|
||||
if (int.TryParse(strValue, out n) && (n >= 0) && n <= 127) return true;
|
||||
case 6:
|
||||
if (ParamValues(i).Contains(str)) return true;
|
||||
break;
|
||||
default:
|
||||
message = "Invalid index";
|
||||
@ -167,11 +191,12 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
void CopyContentTo(UniCBCfg prms)
|
||||
{
|
||||
prms.ComPortNr = ComPortNr;
|
||||
prms.DivertersCount = DivertersCount;
|
||||
prms.DivertersCount = DivertersCount;
|
||||
prms.DrainValvesCount = DrainValvesCount;
|
||||
prms.RegValvesCount = RegValvesCount;
|
||||
prms.VirtValvesRangeLo = VirtValvesRangeLo;
|
||||
prms.VirtValvesRangeHi = VirtValvesRangeHi;
|
||||
prms.RegValvesCount = RegValvesCount;
|
||||
prms.RelaysFInstalled = RelaysFInstalled;
|
||||
prms.RelaysGInstalled = RelaysGInstalled;
|
||||
prms.RelaysHInstalled = RelaysHInstalled;
|
||||
}
|
||||
|
||||
public Config.Entities.IParamsProvider Clone()
|
||||
|
||||
@ -61,9 +61,9 @@ namespace TBF.Rig
|
||||
public static GenericDevices.IValve DrainValve1;
|
||||
public static GenericDevices.IValve DrainValve2;
|
||||
public static GenericDevices.IValve DrainValve3;
|
||||
public static IList<IValve> MasterValves; /// list of directly controlled valves
|
||||
public static IList<IValve> CoupledValves; /// list of coupled valves
|
||||
public static IList<BuiltIn.ValveEx.Valve> ExtendedValves; /// list of extended valves
|
||||
public static IList<IValve> MasterValves; /// list of directly controlled valves
|
||||
public static IList<IValve> CoupledValves; /// list of coupled valves
|
||||
public static IList<BuiltIn.ValveEx.Valve> LogicalFnValves; /// list of logical function valves
|
||||
|
||||
public static IList<string> LoopStartNames;
|
||||
public static IList<string> LoopEndNames;
|
||||
@ -225,7 +225,7 @@ namespace TBF.Rig
|
||||
components = Rig.TbfComponents.LoadComponentsFromDB(cmpntEntities);
|
||||
MasterValves = BuiltIn.ValveBase.GetMasterValves(components);
|
||||
CoupledValves = BuiltIn.ValveBase.CoupledValves(components);
|
||||
ExtendedValves = BuiltIn.ValveBase.ExtendedValves(components);
|
||||
LogicalFnValves = BuiltIn.ValveBase.LogicalFnValves(components);
|
||||
|
||||
ProcessData.ComponentsWithMeasuredVal.Clear();
|
||||
ProcessData.ComponentsWithSetpoint.Clear();
|
||||
@ -400,8 +400,12 @@ namespace TBF.Rig
|
||||
/// </summary>
|
||||
public static void StopDevices()
|
||||
{
|
||||
foreach (var dev in devices)
|
||||
/// StopDevices() functions of devices are called in
|
||||
/// reversed order so that the parent compnent's StopDevices()
|
||||
/// is called after calling StopDevices() of it's children.
|
||||
for (int i = devices.Count - 1; i >= 0; i--)
|
||||
{
|
||||
var dev = devices[i];
|
||||
UiBridge.Bridge.OnActivity(null, string.Format("1. {0}", dev.Name)); /// Info
|
||||
dev.StopDevice();
|
||||
}
|
||||
@ -414,8 +418,12 @@ namespace TBF.Rig
|
||||
/// </summary>
|
||||
public static void StopDevices2()
|
||||
{
|
||||
foreach (var dev in devices)
|
||||
/// StopDevices2() functions of devices are called in
|
||||
/// reversed order so that the parent compnent's StopDevices2()
|
||||
/// is called after calling StopDevices2() of it's children.
|
||||
for (int i = devices.Count - 1; i >= 0; i--)
|
||||
{
|
||||
var dev = devices[i];
|
||||
UiBridge.Bridge.OnActivity(null, string.Format("2. {0}", dev.Name)); /// Info
|
||||
dev.StopDevice2();
|
||||
}
|
||||
@ -812,9 +820,9 @@ namespace TBF.Rig
|
||||
{
|
||||
Thread.Sleep(100); /// Insert 1/10 sec.delay between RunOperations() and RunDeviceAfter()
|
||||
|
||||
/// Call RunDeviceAfter() functions in reversed order
|
||||
/// so that the parent compnent's RunDeviceAfter()
|
||||
/// is called after RunDeviceAfter() of it's children.
|
||||
/// RunDeviceAfter() functions of devices are called in
|
||||
/// reversed order so that the parent compnent's RunDeviceAfter()
|
||||
/// is called after calling RunDeviceAfter() of it's children.
|
||||
for (int i = devices.Count - 1; i >= 0; i--)
|
||||
{
|
||||
devices[i].RunDeviceAfter();
|
||||
|
||||
@ -458,6 +458,12 @@ namespace TBF.UI
|
||||
activityStatusLabel.Text = args.StateChangedMsg;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// This function copies route and process values to the schematic drawing control.
|
||||
/// Schematic drawing is then redrawn accordingly in the next OnPaint().
|
||||
/// </summary>
|
||||
/// <param name="sender"></param>
|
||||
/// <param name="args"></param>
|
||||
void OnStateMachineTick(object sender, StateMachineTickEventArgs args)
|
||||
{
|
||||
drawingCtrl.SupressRedraws = true;
|
||||
|
||||
Loading…
Reference in New Issue