feat(poseidon communication): add V1 diagnostic frame support for C3/C4 data handling
- Introduced support for V1 optical diagnostic frames (C3/C4) with separate processing to prevent interference with metrology data. - Added `DiagnosticTelegramReceived` callback in `OptoHeadService` for detailed logging of V1 frames. - Enhanced `PoseidonOpticalLineParser` to parse and handle C3 calibration factors and C4 auxiliary ADC values. - Implemented a new diagnostic logging method in `SmartReader` for V1 telegrams. - Extended test coverage with new cases to validate C3/C4 frame parsing and diagnostic handling. - Bumped assembly version to 3.9.3176.0.
This commit is contained in:
@@ -32,5 +32,5 @@ using System.Runtime.InteropServices;
|
||||
// Build Number
|
||||
// Revision
|
||||
//
|
||||
[assembly: AssemblyVersion("3.9.3175.0")]
|
||||
[assembly: AssemblyFileVersion("3.9.3175.0")]
|
||||
[assembly: AssemblyVersion("3.9.3176.0")]
|
||||
[assembly: AssemblyFileVersion("3.9.3176.0")]
|
||||
|
||||
@@ -24,6 +24,7 @@ using ConfigStruct = TBF.Rig.RegisterReaders.CommonRR.IPerl.communication.Config
|
||||
using MeterType = TBF.Rig.RegisterReaders.CommonRR.MeterType;
|
||||
using PoseidonOpticalHead = TBF.Rig.RegisterReaders.PoseidonReader.communication.PoseidonOpticalHead;
|
||||
using PoseidonOpticalHeadBuilder = TBF.Rig.RegisterReaders.PoseidonReader.communication.PoseidonOpticalHeadBuilder;
|
||||
using PoseidonOpticalTelegram = TBF.Rig.RegisterReaders.PoseidonReader.communication.PoseidonOpticalTelegram;
|
||||
using PoseidonProtocolProfile = TBF.Rig.RegisterReaders.PoseidonReader.communication.PoseidonProtocolProfile;
|
||||
|
||||
|
||||
@@ -590,6 +591,7 @@ namespace TBF.Rig.RegisterReaders.PoseidonReader
|
||||
diagnosticLastAccumulator = null;
|
||||
diagnosticExtendedAccumulator = 0;
|
||||
_optoHeadService.DiagnosticReceived = CaptureOpticalDiagnostic;
|
||||
_optoHeadService.DiagnosticTelegramReceived = CaptureV1DiagnosticTelegram;
|
||||
bool opened = _optoHeadService.CreateSerialConnection();
|
||||
if (opened && iHeadCfg.ClearOpticalInputOnOpen)
|
||||
_optoHeadService.DiscardPendingInput();
|
||||
@@ -654,6 +656,19 @@ namespace TBF.Rig.RegisterReaders.PoseidonReader
|
||||
null, null, "Stream", data == null ? null : data.ToString());
|
||||
}
|
||||
|
||||
private void CaptureV1DiagnosticTelegram(PoseidonOpticalTelegram telegram)
|
||||
{
|
||||
if (_poseidonCfg == null || telegram == null || (telegram.C3 == null && telegram.C4 == null)) return;
|
||||
string details = telegram.C3 != null ? telegram.C3.ToString() : telegram.C4.ToString();
|
||||
byte[] raw = System.Text.Encoding.ASCII.GetBytes(telegram.RawLine ?? string.Empty);
|
||||
opticalDiagnosticWriter.Write(_poseidonCfg.EnableDetailedLogPerWM,
|
||||
_poseidonCfg.OpticalDiagnosticFormat, _poseidonCfg.RawOpticalDataFormat,
|
||||
_poseidonCfg.IncludeParsedValues, Sequences.ProcessData.BatchNr,
|
||||
Position > 0 ? Position.ToString() : Name, Name, SerialNr, telegram.ReceivedUtc,
|
||||
"OpticalService/V1Diagnostic", "ParsedDiagnostic", raw, telegram.RawLine,
|
||||
null, null, false, null, null, null, null, "Diagnostic", details);
|
||||
}
|
||||
|
||||
private void OnOptoHandler(object sender, CommonRR.IPerl.communication.OptoReceivedEventArgs e)
|
||||
{
|
||||
//received data from optohead
|
||||
|
||||
@@ -76,6 +76,9 @@ namespace TBF.Rig.RegisterReaders.PoseidonReader.communication.C7
|
||||
|
||||
// Driver bytes and parse outcome, including rejected packets.
|
||||
public Action<byte[], DateTime, WaterMetrologyData, bool> DiagnosticReceived { get; set; }
|
||||
// Valid non-metrology V1 frames (for example C3/C4) are exposed
|
||||
// separately so they can be logged without entering the test result.
|
||||
public Action<PoseidonOpticalTelegram> DiagnosticTelegramReceived { get; set; }
|
||||
|
||||
public OptoHeadService(Con con)
|
||||
: this(con, null)
|
||||
@@ -193,10 +196,12 @@ namespace TBF.Rig.RegisterReaders.PoseidonReader.communication.C7
|
||||
}
|
||||
try
|
||||
{
|
||||
// Reflect the CURRENT ParseData branch, including its legacy
|
||||
// simulation condition. Do not label simulated values as wire data.
|
||||
DiagnosticReceived?.Invoke(rawDiagnosticData, receivedUtc, WaterMetrologyData,
|
||||
Connection?.DebugModeSetting != DebugMode.Simulate);
|
||||
// Empty polling is not a rejected frame. Only record actual
|
||||
// COM data (or a produced metrology result) here; parsed C3/C4
|
||||
// frames are recorded through DiagnosticTelegramReceived.
|
||||
if ((rawDiagnosticData != null && rawDiagnosticData.Length > 0) || WaterMetrologyData != null)
|
||||
DiagnosticReceived?.Invoke(rawDiagnosticData, receivedUtc, WaterMetrologyData,
|
||||
Connection?.DebugModeSetting != DebugMode.Simulate);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
@@ -278,6 +283,14 @@ namespace TBF.Rig.RegisterReaders.PoseidonReader.communication.C7
|
||||
log.Warn("Poseidon optical V1 frame rejected: " + error);
|
||||
return null;
|
||||
}
|
||||
try
|
||||
{
|
||||
DiagnosticTelegramReceived?.Invoke(telegram);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
log.Warn("Poseidon V1 diagnostic telegram callback failed.", ex);
|
||||
}
|
||||
if (telegram.C7 != null) return WaterMetrologyData.FromC7(telegram.C7);
|
||||
if (telegram.C2 != null) return WaterMetrologyData.FromC2(telegram.C2);
|
||||
return null;
|
||||
|
||||
@@ -9,12 +9,88 @@ namespace TBF.Rig.RegisterReaders.PoseidonReader.communication
|
||||
public int Sequence { get; internal set; }
|
||||
public byte MessageType { get; internal set; }
|
||||
public string Payload { get; internal set; }
|
||||
/// <summary>Complete V1 line, retained for diagnostic logging.</summary>
|
||||
public string RawLine { get; internal set; }
|
||||
public WaterMetrologyDataC2 C2 { get; internal set; }
|
||||
public WaterMetrologyDataC7 C7 { get; internal set; }
|
||||
public PoseidonMetrologyCalibrationFactors C3 { get; internal set; }
|
||||
public PoseidonAuxAdcValues C4 { get; internal set; }
|
||||
public PoseidonSystemInfoData SystemInfo { get; internal set; }
|
||||
public PoseidonMeterTime MeterTime { get; internal set; }
|
||||
}
|
||||
|
||||
/// <summary>V1 type C3. These values are diagnostic calibration data and
|
||||
/// are deliberately not used by the metrology calculation.</summary>
|
||||
public sealed class PoseidonMetrologyCalibrationFactors
|
||||
{
|
||||
public ushort MetrologyCalibrationFactor { get; private set; }
|
||||
public short AsicTemperatureCalibration { get; private set; }
|
||||
public short FieldSenseCalibrationFactor { get; private set; }
|
||||
public int FieldFitCoefficientA0 { get; private set; }
|
||||
public int FieldFitCoefficientA1 { get; private set; }
|
||||
public ushort FieldDriveStepMagnitude { get; private set; }
|
||||
|
||||
internal static PoseidonMetrologyCalibrationFactors Parse(string payload)
|
||||
{
|
||||
byte[] bytes = Convert.FromBase64String(payload);
|
||||
if (bytes.Length != 16) throw new ArgumentException("C3 payload must contain 16 bytes.");
|
||||
return new PoseidonMetrologyCalibrationFactors
|
||||
{
|
||||
MetrologyCalibrationFactor = BitConverter.ToUInt16(bytes, 0),
|
||||
AsicTemperatureCalibration = BitConverter.ToInt16(bytes, 2),
|
||||
FieldSenseCalibrationFactor = BitConverter.ToInt16(bytes, 4),
|
||||
FieldFitCoefficientA0 = BitConverter.ToInt32(bytes, 6),
|
||||
FieldFitCoefficientA1 = BitConverter.ToInt32(bytes, 10),
|
||||
FieldDriveStepMagnitude = BitConverter.ToUInt16(bytes, 14)
|
||||
};
|
||||
}
|
||||
|
||||
public override string ToString()
|
||||
{
|
||||
return string.Format("C3 calibration: Metrology={0}, AsicTemperature={1}, FieldSense={2}, A0={3}, A1={4}, DriveStep={5}",
|
||||
MetrologyCalibrationFactor, AsicTemperatureCalibration, FieldSenseCalibrationFactor,
|
||||
FieldFitCoefficientA0, FieldFitCoefficientA1, FieldDriveStepMagnitude);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>One V1 type C4 auxiliary ADC sample and its source identifier.</summary>
|
||||
public sealed class PoseidonAuxAdcValue
|
||||
{
|
||||
public ushort Sample { get; internal set; }
|
||||
public byte Source { get; internal set; }
|
||||
}
|
||||
|
||||
/// <summary>V1 type C4. Auxiliary ADC values are diagnostic only.</summary>
|
||||
public sealed class PoseidonAuxAdcValues
|
||||
{
|
||||
public PoseidonAuxAdcValue[] Values { get; private set; }
|
||||
|
||||
internal static PoseidonAuxAdcValues Parse(string payload)
|
||||
{
|
||||
byte[] bytes = Convert.FromBase64String(payload);
|
||||
if (bytes.Length != 24) throw new ArgumentException("C4 payload must contain 24 bytes.");
|
||||
PoseidonAuxAdcValue[] values = new PoseidonAuxAdcValue[8];
|
||||
for (int i = 0; i < values.Length; i++)
|
||||
{
|
||||
int offset = i * 3;
|
||||
values[i] = new PoseidonAuxAdcValue
|
||||
{
|
||||
Sample = BitConverter.ToUInt16(bytes, offset),
|
||||
Source = bytes[offset + 2]
|
||||
};
|
||||
}
|
||||
return new PoseidonAuxAdcValues { Values = values };
|
||||
}
|
||||
|
||||
public override string ToString()
|
||||
{
|
||||
string[] values = new string[Values == null ? 0 : Values.Length];
|
||||
for (int i = 0; i < values.Length; i++)
|
||||
values[i] = string.Format("ADC{0}={1} (source {2})", i, Values[i].Sample, Values[i].Source);
|
||||
return "C4 auxiliary ADC: " + string.Join(", ", values);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Parser of an entire CR/LF terminated optical line. The caller is
|
||||
/// responsible for stamping it at the serial-port boundary, before queuing.</summary>
|
||||
public sealed class PoseidonOpticalLineParser
|
||||
@@ -55,7 +131,10 @@ namespace TBF.Rig.RegisterReaders.PoseidonReader.communication
|
||||
if (XModemCrc16(crcText) != receivedCrc) { error = "Optical frame CRC16 mismatch."; return false; }
|
||||
bool isExpectedMeasurement = (byte)messageType == profile.ExpectedMessageType;
|
||||
bool isSystemInfo = (byte)messageType == 0xF0 && profile.ParseSystemInfo;
|
||||
if (!isExpectedMeasurement && !isSystemInfo)
|
||||
// C3/C4 are valid, intermittently emitted diagnostic payloads. They
|
||||
// must not be treated as metrology samples or change the timing path.
|
||||
bool isDiagnostic = (byte)messageType == 0xC3 || (byte)messageType == 0xC4;
|
||||
if (!isExpectedMeasurement && !isSystemInfo && !isDiagnostic)
|
||||
{
|
||||
error = string.Format("Unexpected optical message type 0x{0:X2}; expected 0x{1:X2}{2}.",
|
||||
messageType, profile.ExpectedMessageType, profile.ParseSystemInfo ? " or F0 System Info" : "");
|
||||
@@ -69,7 +148,8 @@ namespace TBF.Rig.RegisterReaders.PoseidonReader.communication
|
||||
ReceivedUtc = utc,
|
||||
Sequence = sequence,
|
||||
MessageType = (byte)messageType,
|
||||
Payload = fields[2]
|
||||
Payload = fields[2],
|
||||
RawLine = line.TrimEnd('\r', '\n')
|
||||
};
|
||||
if (isSystemInfo)
|
||||
{
|
||||
@@ -84,6 +164,14 @@ namespace TBF.Rig.RegisterReaders.PoseidonReader.communication
|
||||
IsEstimated = false
|
||||
};
|
||||
}
|
||||
else if ((byte)messageType == 0xC3)
|
||||
{
|
||||
telegram.C3 = PoseidonMetrologyCalibrationFactors.Parse(fields[2]);
|
||||
}
|
||||
else if ((byte)messageType == 0xC4)
|
||||
{
|
||||
telegram.C4 = PoseidonAuxAdcValues.Parse(fields[2]);
|
||||
}
|
||||
else
|
||||
{
|
||||
if (profile.MeterTimeCompensation == PoseidonMeterTimeCompensation.RequireSystemInfoAnchor && latestSystemInfo == null)
|
||||
|
||||
@@ -8,7 +8,7 @@ namespace TBFTests.Rig.RegisterReaders.PoseidonReader
|
||||
public class PoseidonProtocolProfileTests
|
||||
{
|
||||
[TestMethod]
|
||||
public void B102AProfileSeparatesWrittenModeFromExpectedC7Telegram()
|
||||
public void B102AProfileUsesC1ForWrittenModeAndExpectedTelegram()
|
||||
{
|
||||
PoseidonProtocolProfile profile = PoseidonProtocolProfileBuilder
|
||||
.ForFirmware(PoseidonFirmwareGeneration.B1_0_2A)
|
||||
@@ -16,7 +16,7 @@ namespace TBFTests.Rig.RegisterReaders.PoseidonReader
|
||||
|
||||
Assert.AreEqual(PoseidonOpticalProtocol.V1C1FilteredC7, profile.OpticalProtocol);
|
||||
Assert.AreEqual((byte)0xC1, profile.OpticalDataMode);
|
||||
Assert.AreEqual((byte)0xC7, profile.ExpectedMessageType);
|
||||
Assert.AreEqual((byte)0xC1, profile.ExpectedMessageType);
|
||||
Assert.AreEqual(38400, profile.OpticalBaudRate);
|
||||
}
|
||||
|
||||
@@ -60,6 +60,35 @@ namespace TBFTests.Rig.RegisterReaders.PoseidonReader
|
||||
StringAssert.Contains(error, "CRC16");
|
||||
}
|
||||
|
||||
[TestMethod]
|
||||
public void V1C3AndC4DiagnosticFramesParseWithoutBecomingMetrology()
|
||||
{
|
||||
PoseidonProtocolProfile profile = PoseidonProtocolProfileBuilder
|
||||
.ForFirmware(PoseidonFirmwareGeneration.B1_0_2A)
|
||||
.Build();
|
||||
PoseidonOpticalLineParser parser = new PoseidonOpticalLineParser(profile);
|
||||
PoseidonOpticalTelegram c3;
|
||||
PoseidonOpticalTelegram c4;
|
||||
string error;
|
||||
|
||||
Assert.IsTrue(parser.TryParse(CreateFrame("1A", "C3", "fQwAAEELFokFAMoFAACGBQ=="),
|
||||
DateTime.UtcNow, out c3, out error), error);
|
||||
Assert.IsNull(c3.C2);
|
||||
Assert.IsNull(c3.C7);
|
||||
Assert.AreEqual((ushort)3197, c3.C3.MetrologyCalibrationFactor);
|
||||
Assert.AreEqual(362774, c3.C3.FieldFitCoefficientA0);
|
||||
|
||||
Assert.IsTrue(parser.TryParse(CreateFrame("16", "C4", "tAcIMA8OnQ0HLg8KxA4KXQIMBwgJAAAA"),
|
||||
DateTime.UtcNow, out c4, out error), error);
|
||||
Assert.IsNull(c4.C2);
|
||||
Assert.IsNull(c4.C7);
|
||||
Assert.AreEqual(8, c4.C4.Values.Length);
|
||||
Assert.AreEqual((ushort)1972, c4.C4.Values[0].Sample);
|
||||
Assert.AreEqual((byte)8, c4.C4.Values[0].Source);
|
||||
Assert.AreEqual((ushort)0, c4.C4.Values[7].Sample);
|
||||
Assert.AreEqual((byte)0, c4.C4.Values[7].Source);
|
||||
}
|
||||
|
||||
[TestMethod]
|
||||
public void ParsingWithMeterTimeUsesF0AnchorForFollowingC7()
|
||||
{
|
||||
|
||||
Reference in New Issue
Block a user