Files
tbf/TBF/Rig/RegisterReaders/PoseidonReader/communication/C7/OptoHeadService.cs
T
michal 6eeaa113f5 feat(poseidon communication): add V1 diagnostic frame support for C3/C4 data handling
- Introduced support for V1 optical diagnostic frames (C3/C4) with separate processing to prevent interference with metrology data.
- Added `DiagnosticTelegramReceived` callback in `OptoHeadService` for detailed logging of V1 frames.
- Enhanced `PoseidonOpticalLineParser` to parse and handle C3 calibration factors and C4 auxiliary ADC values.
- Implemented a new diagnostic logging method in `SmartReader` for V1 telegrams.
- Extended test coverage with new cases to validate C3/C4 frame parsing and diagnostic handling.
- Bumped assembly version to 3.9.3176.0.
2026-10-19 15:12:23 +02:00

323 lines
13 KiB
C#

using System;
using System.IO.Ports;
using System.Text;
using System.Threading.Tasks;
using Common;
using log4net;
using TBF.Rig.RegisterReaders.PoseidonReader.communication.C7.Protocols;
using TBF.Rig.Sequences;
using TBF.Rig.RegisterReaders.PoseidonReader.communication;
using SERIAL_Driver = TBF.Rig.RegisterReaders.PoseidonReader.communication.C7.Utils.SERIAL_Driver;
using WaterMetrologyData = TBF.Rig.RegisterReaders.PoseidonReader.communication.C7.Protocols.WaterMetrologyData;
namespace TBF.Rig.RegisterReaders.PoseidonReader.communication.C7
{
public class OptoHeadService
{
static readonly ILog log = LogManager.GetLogger("PoseidonConnection");
// This logger is intentionally separate from the general connection log.
// It is used by the manual optical test as well as the test-run reader.
static readonly ILog opticalTraceLog = LogManager.GetLogger("PoseidonOptical");
public class Con
{
public string com = "COM5";
public int baudrate = 38400;
public int dataBits = 8;
public Parity parity = Parity.None;
// Poseidon optical output is specified as 38400 8-N-1.
public StopBits stopbits = StopBits.One;
public int readTimeout = 5000;
public int writeTimeout = 1000;
private DebugMode _debugLevel;
public DebugMode DebugModeSetting { get => _debugLevel; }
public Con(string com, int baudrate, int dataBits, Parity parity, StopBits stopbits, int readTimeout,
int writeTimeout) : this(com)
{
this.baudrate = baudrate;
this.dataBits = dataBits;
this.parity = parity;
this.stopbits = stopbits;
this.readTimeout = readTimeout;
this.writeTimeout = writeTimeout;
}
public Con(DebugMode debugLevel,string com, int baudrate, int dataBits, Parity parity, StopBits stopbits, int readTimeout,
int writeTimeout) : this(com)
{
this._debugLevel = debugLevel;
this.baudrate = baudrate;
this.dataBits = dataBits;
this.parity = parity;
this.stopbits = stopbits;
this.readTimeout = readTimeout;
this.writeTimeout = writeTimeout;
}
public Con(string com, DebugMode debugLevel = DebugMode.Normal)
{
this.com = com;
this._debugLevel = debugLevel;
}
}
private Con Connection { get; set; }
private SERIAL_Driver driver;
private readonly PoseidonProtocolProfile protocolProfile;
private readonly StringBuilder opticalTextBuffer = new StringBuilder();
private PoseidonOpticalLineParser opticalLineParser;
private DateTime bufferedLineReceivedUtc = DateTime.MinValue;
/// <summary>
/// Filed After Run() is called.
/// </summary>
public WaterMetrologyData WaterMetrologyData { get; private set; }
// Driver bytes and parse outcome, including rejected packets.
public Action<byte[], DateTime, WaterMetrologyData, bool> DiagnosticReceived { get; set; }
// Valid non-metrology V1 frames (for example C3/C4) are exposed
// separately so they can be logged without entering the test result.
public Action<PoseidonOpticalTelegram> DiagnosticTelegramReceived { get; set; }
public OptoHeadService(Con con)
: this(con, null)
{
}
public OptoHeadService(Con con, PoseidonProtocolProfile profile)
{
Connection = con;
protocolProfile = profile;
opticalLineParser = profile == null ? null : new PoseidonOpticalLineParser(profile);
driver = new SERIAL_Driver();
OnOptoReceivedHandler = null;
}
public bool CreateSerialConnection()
{
OnOptoReceivedHandler = null;
dissableRunLoop = false;
opticalTextBuffer.Length = 0;
bufferedLineReceivedUtc = DateTime.MinValue;
if (opticalLineParser != null) opticalLineParser.ResetMeterTimeAnchor();
bool isopen = false;
Con con = Connection;
if (con == null)
{
return false;
}
byte[] message = {0x00};
byte[] bytesReceived;
if (con?.DebugModeSetting == DebugMode.Simulate)
{
isopen = true;
}
else if (!driver.isOpen())
{
isopen = driver.OpenConnection(
con.com,
con.baudrate,
con.dataBits,
con.parity,
con.stopbits,
con.readTimeout,
con.writeTimeout);
}
_bRunStarted = false;
return isopen;
}
/// <summary>Discard bytes received before a measurement capture starts.</summary>
public void DiscardPendingInput()
{
opticalTextBuffer.Length = 0;
bufferedLineReceivedUtc = DateTime.MinValue;
driver.DiscardInputBuffer();
}
public void CloseSerialConnection()
{
dissableRunLoop = true;
OnOptoReceivedHandler = null;
if (Connection?.DebugModeSetting != DebugMode.Simulate)
{
driver.Close();
}
_bRunStarted = false;
}
private EventHandler<CommonRR.IPerl.communication.OptoReceivedEventArgs> OnOptoReceivedHandler;
public bool IsRunning
{
get { return !dissableRunLoop
&& ((Connection?.DebugModeSetting != DebugMode.Simulate) ? driver.isOpen() : true)
&& _bRunStarted;}
}
public void RunLoop(EventHandler<CommonRR.IPerl.communication.OptoReceivedEventArgs> onOptoReceivedHandler)
{
log.Debug("RunLoop started on event!");
OnOptoReceivedHandler = onOptoReceivedHandler;
Task.Run(() => Run());
}
public void RunLoop()
{
log.Debug("RunLoop started!");
Task.Run(() => Run());
}
private bool dissableRunLoop = false;
private bool _bRunStarted = false;
/// <summary>
/// Run the service. Catch one communication to WaterMetrologyData field.
/// </summary>
public void Run()
{
while (!dissableRunLoop)
{
_bRunStarted = true;
DateTime receivedUtc;
byte[] rawDiagnosticData = RunReading(out receivedUtc);
WaterMetrologyData = ParseData(rawDiagnosticData, receivedUtc);
if (OnOptoReceivedHandler != null && WaterMetrologyData != null)
{
log.Debug($"Received OptoData: {WaterMetrologyData}");
OnOptoReceivedHandler?.Invoke(this, new CommonRR.IPerl.communication.OptoReceivedEventArgs(WaterMetrologyData?.ToString(), WaterMetrologyData));
}
try
{
// Empty polling is not a rejected frame. Only record actual
// COM data (or a produced metrology result) here; parsed C3/C4
// frames are recorded through DiagnosticTelegramReceived.
if ((rawDiagnosticData != null && rawDiagnosticData.Length > 0) || WaterMetrologyData != null)
DiagnosticReceived?.Invoke(rawDiagnosticData, receivedUtc, WaterMetrologyData,
Connection?.DebugModeSetting != DebugMode.Simulate);
}
catch (Exception ex)
{
log.Warn("Poseidon optical diagnostic callback failed.", ex);
}
}
}
byte[] RunReading(out DateTime receivedUtc)
{
receivedUtc = DateTime.UtcNow;
if (Connection?.DebugModeSetting == DebugMode.Simulate)
{
return new byte[] {0x00};
}
if (driver.isOpen())
{
byte[] rawData = driver.GetRawData();
// Capture immediately after the COM read, before diagnostics or
// parsing. This is the PC/UTC timestamp defined for V1 logs.
receivedUtc = DateTime.UtcNow;
if (rawData == null)
System.Threading.Thread.Sleep(10);
log.Debug($"Received data size: {rawData?.Length ?? 0} bytes, raw data: {(rawData==null? "" :BitConverter.ToString(rawData))}");
if (rawData != null && rawData.Length > 0)
{
// Preserve the exact data received from COM, including fragments of a
// V1 line. The parser may need several callbacks before a CR/LF-terminated
// telegram is available, so logging must happen before parsing.
opticalTraceLog.Info("Incoming optical stream; source=COM; port=" +
(Connection?.com ?? "unknown") + "; bytes=" + rawData.Length +
"; raw=" + EscapeOpticalBytes(rawData));
}
return rawData;
}
else
{
log.Debug("Serial port is not open.");
dissableRunLoop = true;
}
return new byte[] {0xFF};
}
public WaterMetrologyData ParseData(byte[] data)
{
return ParseData(data, DateTime.UtcNow);
}
internal WaterMetrologyData ParseData(byte[] data, DateTime receivedUtc)
{
if (Connection?.DebugModeSetting == DebugMode.Simulate)
{
return WaterMetrologyData.SimulateC7();
}
try
{
if (protocolProfile != null && protocolProfile.OpticalProtocol != PoseidonOpticalProtocol.LegacyV0)
{
if (data != null && data.Length > 0)
{
if (opticalTextBuffer.Length == 0)
bufferedLineReceivedUtc = receivedUtc;
opticalTextBuffer.Append(Encoding.ASCII.GetString(data));
}
int lineEnd = opticalTextBuffer.ToString().IndexOf('\n');
if (lineEnd < 0)
return null;
string line = opticalTextBuffer.ToString(0, lineEnd + 1);
opticalTextBuffer.Remove(0, lineEnd + 1);
PoseidonOpticalTelegram telegram;
string error;
DateTime lineReceivedUtc = bufferedLineReceivedUtc == DateTime.MinValue ? receivedUtc : bufferedLineReceivedUtc;
bufferedLineReceivedUtc = opticalTextBuffer.Length == 0 ? DateTime.MinValue : receivedUtc;
if (!opticalLineParser.TryParse(line, lineReceivedUtc, out telegram, out error))
{
log.Warn("Poseidon optical V1 frame rejected: " + error);
return null;
}
try
{
DiagnosticTelegramReceived?.Invoke(telegram);
}
catch (Exception ex)
{
log.Warn("Poseidon V1 diagnostic telegram callback failed.", ex);
}
if (telegram.C7 != null) return WaterMetrologyData.FromC7(telegram.C7);
if (telegram.C2 != null) return WaterMetrologyData.FromC2(telegram.C2);
return null;
}
if (data == null || data.Length == 0)
return null;
return WaterMetrologyData.Parse(data, DateTime.Now, "");
}catch(Exception e)
{
return null;
}
}
private static string EscapeOpticalBytes(byte[] data)
{
var result = new StringBuilder();
foreach (byte value in data)
{
if (value == 92) result.Append(@"\\");
else if (value == 13) result.Append(@"\r");
else if (value == 10) result.Append(@"\n");
else if (value == 9) result.Append(@"\t");
else if (value >= 32 && value <= 126) result.Append((char)value);
else result.Append(@"\x").Append(value.ToString("X2"));
}
return result.ToString();
}
}
}