ProductionUiCordonel: - ASBL: - check mapping
This commit is contained in:
@@ -225,7 +225,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// <inheritdoc />
|
||||
public String MeterSize
|
||||
{
|
||||
set; get;
|
||||
protected set; get;
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
@@ -265,7 +265,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// <inheritdoc />
|
||||
public Boolean PressureSensorAssembled
|
||||
{
|
||||
set; get;
|
||||
protected set; get;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
@@ -492,6 +492,15 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Unlocked the property change ability for special sequences.
|
||||
/// </summary>
|
||||
public Boolean UnlockEssentialProperties
|
||||
{
|
||||
get;
|
||||
protected set;
|
||||
}
|
||||
|
||||
#endregion
|
||||
|
||||
#region Setup
|
||||
@@ -522,6 +531,61 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Unlocked the property change ability for special sequences.
|
||||
/// </summary>
|
||||
/// <param name="unlockPropertyChange">true if unlock required</param>
|
||||
/// <returns>true if possible</returns>
|
||||
public Boolean EnablePropertyChangeAbility(Boolean unlockPropertyChange)
|
||||
{
|
||||
UnlockEssentialProperties = unlockPropertyChange;
|
||||
return true;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Set the meter size if previously unlocked
|
||||
/// </summary>
|
||||
/// <param name="meterSize">true if setting is allowed</param>
|
||||
/// <returns>true if possible</returns>
|
||||
public virtual Boolean SetMeterSize<T>(T meterSize)
|
||||
{
|
||||
if (!UnlockEssentialProperties)
|
||||
return false;
|
||||
|
||||
if (meterSize is String)
|
||||
{
|
||||
var ms = meterSize.ToString();
|
||||
if (Logic.ProductionOrderCore.OrderData.MeterSize.NA == MeterSizeConverter.ConvertMeterSizeNameToEnum(ms))
|
||||
return false;
|
||||
MeterSize = ms;
|
||||
}
|
||||
else if (meterSize.GetType() == typeof(MeterSize))
|
||||
{
|
||||
var ms = Convert.ToInt32(meterSize);
|
||||
MeterSize = MeterSizeConverter.ConvertMeterSizeEnumToSizeName((MeterSize)ms);
|
||||
}
|
||||
else // Type is unknown
|
||||
{
|
||||
return false;
|
||||
}
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Set the pressure sensor if previously unlocked
|
||||
/// </summary>
|
||||
/// <param name="pressureSensorAssembled">true if setting is allow</param>
|
||||
/// <returns>true if possible</returns>
|
||||
public Boolean SetPressureSensorAssembled(Boolean pressureSensorAssembled)
|
||||
{
|
||||
if (!UnlockEssentialProperties)
|
||||
return false;
|
||||
PressureSensorAssembled = pressureSensorAssembled;
|
||||
return true;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Returns meter registers
|
||||
/// </summary>
|
||||
|
||||
@@ -7,6 +7,7 @@ using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig;
|
||||
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts;
|
||||
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
|
||||
using Xylem.Common.Hardware.WaterMeter.WaterMeterCore;
|
||||
using Xylem.Common.Logic.ProductionOrderCore.OrderData;
|
||||
|
||||
namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
{
|
||||
@@ -15,9 +16,6 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// </summary>
|
||||
public interface IGenesisMeter : IMeter
|
||||
{
|
||||
|
||||
|
||||
|
||||
#region properties
|
||||
/// <summary>
|
||||
/// Represent <see cref="Register.Configexchange.PcbSerialNumber" />
|
||||
@@ -55,7 +53,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// <summary>
|
||||
/// Transmit protocol access for underlie objects to change response timeout
|
||||
/// </summary>
|
||||
ITransmitProtocol TransmitProtocol{ get; }
|
||||
ITransmitProtocol TransmitProtocol { get; }
|
||||
|
||||
/// <summary>
|
||||
/// List of all present meter applications installed in meter
|
||||
@@ -116,7 +114,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// <summary>
|
||||
/// This is the meter size.
|
||||
/// </summary>
|
||||
String MeterSize { get; set; }
|
||||
String MeterSize { get; }
|
||||
|
||||
/// <summary>
|
||||
/// Length of the meter.
|
||||
@@ -126,7 +124,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// <summary>
|
||||
/// Pressure sensor assembled to meter.
|
||||
/// </summary>
|
||||
Boolean PressureSensorAssembled { get; set; }
|
||||
Boolean PressureSensorAssembled { get; }
|
||||
|
||||
/// <summary>
|
||||
/// Region (EMEA, NA or China).
|
||||
@@ -184,6 +182,14 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
get; set;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Unlocked the property change ability for special sequences.
|
||||
/// </summary>
|
||||
Boolean UnlockEssentialProperties
|
||||
{
|
||||
get;
|
||||
}
|
||||
|
||||
#endregion
|
||||
|
||||
#region methods
|
||||
@@ -194,6 +200,22 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// </summary>
|
||||
void CheckRegionSizeLutCrc();
|
||||
|
||||
/// <summary>
|
||||
/// Unlocked the property change ability for special sequences.
|
||||
/// </summary>
|
||||
Boolean EnablePropertyChangeAbility(Boolean unlockPropertyChange);
|
||||
|
||||
/// <summary>
|
||||
/// Set the meter size if previously unlocked.
|
||||
/// The data types are: - String like "DN50" or
|
||||
/// </summary>
|
||||
Boolean SetMeterSize<T>(T meterSize);
|
||||
|
||||
/// <summary>
|
||||
/// Set the pressure sensor if previously unlocked
|
||||
/// </summary>
|
||||
Boolean SetPressureSensorAssembled(Boolean pressureSensorAssembled);
|
||||
|
||||
/// <summary>
|
||||
/// Reset the empty pipe alarm
|
||||
/// </summary>
|
||||
@@ -228,7 +250,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
MeterRegisters GetConfigRegistersDefinitions();
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Common routine for reboot being able to override this routine which will be called in
|
||||
/// MeteResetPsu to simulate a reboot.
|
||||
@@ -259,7 +281,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// <returns>value as byte array in raw format or null</returns>
|
||||
Byte[] ReadRegister(String regName, Int32? expectedLength = null,
|
||||
UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode);
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Clear all pending alarms.
|
||||
/// </summary>
|
||||
|
||||
@@ -12,6 +12,7 @@ using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore;
|
||||
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisFile;
|
||||
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
|
||||
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers.DataTypes;
|
||||
using Xylem.Common.Logic.ProductionOrderCore.OrderData;
|
||||
using Xylem.Common.Logic.ProductionOrderCore.TestResults;
|
||||
|
||||
namespace Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis
|
||||
@@ -169,7 +170,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis
|
||||
/// </summary>
|
||||
public new String MeterSize
|
||||
{
|
||||
set => base.MeterSize = value;
|
||||
private set => base.MeterSize = value;
|
||||
get => base.MeterSize;
|
||||
}
|
||||
|
||||
@@ -187,7 +188,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis
|
||||
/// </summary>
|
||||
public new Boolean PressureSensorAssembled
|
||||
{
|
||||
set => base.PressureSensorAssembled = value;
|
||||
private set => base.PressureSensorAssembled = value;
|
||||
get => base.PressureSensorAssembled;
|
||||
}
|
||||
|
||||
@@ -759,6 +760,45 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis
|
||||
return IsLoggedOn;
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
/// <summary>
|
||||
/// Set the meter size if previously unlocked.
|
||||
/// - MockGenesis allows additional empty string or question mark string!
|
||||
/// </summary>
|
||||
/// <param name="meterSize">true if setting is allowed</param>
|
||||
/// <returns>true if possible</returns>
|
||||
public override Boolean SetMeterSize<T>(T meterSize)
|
||||
{
|
||||
if (!UnlockEssentialProperties)
|
||||
return false;
|
||||
|
||||
if (meterSize is String)
|
||||
{
|
||||
var ms = meterSize.ToString();
|
||||
// MockGenesis allows 'killing' of MeterSize
|
||||
if (Equals(meterSize,"") || Equals(meterSize,"?"))
|
||||
{
|
||||
|
||||
}
|
||||
else if (Logic.ProductionOrderCore.OrderData.MeterSize.NA == MeterSizeConverter.ConvertMeterSizeNameToEnum(ms))
|
||||
{
|
||||
return false;
|
||||
}
|
||||
MeterSize = ms;
|
||||
}
|
||||
else if (meterSize.GetType() == typeof(MeterSize))
|
||||
{
|
||||
var ms = Convert.ToInt32(meterSize);
|
||||
MeterSize = MeterSizeConverter.ConvertMeterSizeEnumToSizeName((MeterSize)ms);
|
||||
}
|
||||
else // Type is unknown
|
||||
{
|
||||
return false;
|
||||
}
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
/// <summary>
|
||||
/// Simulate login with password to mock Genesis for test purposes
|
||||
|
||||
+12
-2
@@ -1036,7 +1036,12 @@ namespace Xylem.Common.Production.ProductionUiCordonel.UnitTests.Steps
|
||||
|
||||
if (ParseString(tableRow, "Cordonel Meter Size", out strValue))
|
||||
{
|
||||
if (parsedTableRow.Meter != null) parsedTableRow.Meter.MeterSize = strValue;
|
||||
//if (parsedTableRow.Meter != null) parsedTableRow.Meter.MeterSize = strValue;
|
||||
if (parsedTableRow.Meter != null)
|
||||
{
|
||||
parsedTableRow.Meter.EnablePropertyChangeAbility(true);
|
||||
parsedTableRow.Meter.SetMeterSize(strValue);
|
||||
}
|
||||
}
|
||||
|
||||
if (ParseString(tableRow, "Requirement Meter Size", out strValue))
|
||||
@@ -1453,7 +1458,12 @@ namespace Xylem.Common.Production.ProductionUiCordonel.UnitTests.Steps
|
||||
else if (!string.IsNullOrEmpty(strValue) && strValue.Equals("X"))
|
||||
{
|
||||
singleSelectionLock = true;
|
||||
if (parsedTableRow.Meter != null) parsedTableRow.Meter.MeterSize = "?";
|
||||
|
||||
if (parsedTableRow.Meter != null)
|
||||
{
|
||||
parsedTableRow.Meter.EnablePropertyChangeAbility(true);
|
||||
parsedTableRow.Meter.SetMeterSize("?");
|
||||
}
|
||||
parsedTableRow.RequiredEOLProgress.ProductionStatusMeterSize = "";
|
||||
}
|
||||
}
|
||||
|
||||
+1
-1
@@ -464,7 +464,7 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.Gener
|
||||
feedbackMsg = isSpecialActive &&
|
||||
productionRequirements.SpecialId != null &&
|
||||
productionRequirements.SpecialVersion != null ?
|
||||
Resources.StrWarningMsgSpecialRequirementActive +
|
||||
Resources.StrAttentionMsgSpecialRequirementActive +
|
||||
$" Id.Ver: {productionRequirements.SpecialId}.{productionRequirements.SpecialVersion}" :
|
||||
Resources.StrSuccessMsgRequirementActive +
|
||||
$" Id.Ver {productionRequirements.StandardId}.{productionRequirements.StandardVersion}";
|
||||
|
||||
+53
-11
@@ -1,6 +1,7 @@
|
||||
using System;
|
||||
using Xylem.Common.CommonCore.Consts;
|
||||
using Xylem.Common.Logic.ProductionOrderCore.OrderData;
|
||||
using Resources = Xylem.Common.Production.ProductionUiCordonel.Properties.Resources;
|
||||
|
||||
namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.PickingProcesses
|
||||
{
|
||||
@@ -13,7 +14,7 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.Picki
|
||||
/// Ctor
|
||||
/// Setup of name and single process state
|
||||
/// </summary>
|
||||
public CheckCordonelMapping(String name) : base( name)
|
||||
public CheckCordonelMapping(String name) : base(name)
|
||||
{
|
||||
}
|
||||
|
||||
@@ -23,10 +24,11 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.Picki
|
||||
/// - Check if order is different from actual scanned order,
|
||||
/// - Check if older box with octopussies is on stock,
|
||||
/// - Preserve picking number for this Cordonel.
|
||||
/// Precondition: - Detection of Cordonel has to be finished.
|
||||
/// Precondition: - Detection of Cordonel has to be finished,
|
||||
/// - Meter.OrderNumber has to be assigned after scan.
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
/// <remarks date="2025-Sep-22" author="Thomas Wiedebusch">
|
||||
/// <remarks date="2025-Sep-25" author="Thomas Wiedebusch">
|
||||
/// - Initial
|
||||
/// </remarks>
|
||||
public override StatusReturn ExecuteProcess()
|
||||
@@ -37,25 +39,65 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.Picki
|
||||
}
|
||||
|
||||
SignalRunningState();
|
||||
|
||||
|
||||
// Check mapping information
|
||||
if (!OrderDetailsDb.GetCordonelMapping(Meter.PcbId, out var cordonelMapping))
|
||||
if (!OrderDetailsDb.GetCordonelMapping(Meter.PcbId, out var cordonelMapping) ||
|
||||
cordonelMapping == null || cordonelMapping.Count == 0)
|
||||
{
|
||||
ErrorMsgDispatcher(Resources.StrErrorMsgMissingMappingInformation);
|
||||
return StatusReturn.Failed;
|
||||
}
|
||||
// Reserve picking for this device
|
||||
|
||||
// Get detailed order information to set e.g. the correct meter size needed for LUT
|
||||
// installation
|
||||
// Check if this meter is mapped to a different order
|
||||
if (cordonelMapping[0].CordonelAssignedPicking_FertigungsAuftragsNr != null &&
|
||||
cordonelMapping[0].CordonelAssignedPicking_FertigungsAuftragsNr != Meter.OrderNumber)
|
||||
{
|
||||
ErrorMsgDispatcher(Resources.StrErrorMsgMeterForOtherOrderAssigned +
|
||||
$": {cordonelMapping[0].CordonelAssignedPicking_FertigungsAuftragsNr}");
|
||||
return StatusReturn.Failed;
|
||||
}
|
||||
|
||||
// Check if meter is already married to a serial number on a previous run
|
||||
if (cordonelMapping[0].MapPcbIdToSerialNumber_SerialNumber != null)
|
||||
{
|
||||
WarningMsgDispatcher(Resources.StrWarningMsgCordonelIsAlreadyMarried);
|
||||
Meter.SerialNumber = cordonelMapping[0].MapPcbIdToSerialNumber_SerialNumber.ToString();
|
||||
}
|
||||
|
||||
// Reserve picking for this device to lock other assembly line software to assign another Cordonel to
|
||||
// this order.
|
||||
|
||||
// Get detailed order information to set e.g. the correct meter size needed for LUT installation
|
||||
if (!OrderDetailsDb.GetOrderDetails(Meter.OrderNumber, Meter.PcbId, out var orderDetails))
|
||||
{
|
||||
ErrorMsgDispatcher(Resources.StrErrorMsgMissingOrderInformation);
|
||||
return StatusReturn.Failed;
|
||||
}
|
||||
|
||||
// Meter has to be connected in advance being able to overwrite the meter size
|
||||
Meter.MeterSize = MeterSizeConverter.ConvertMeterSizeEnumToSizeName((MeterSize)orderDetails.MeterSize);
|
||||
Meter.PressureSensorAssembled = orderDetails.PressurePresent;
|
||||
// Meter has to be connected in advance being able to overwrite the meter size. The meterSize will be
|
||||
// read out from Cordonel at Connect. This may be reassigned dependent on the orderDetails.MeterSize.
|
||||
// This meter size is the base for all following process steps e.g. loading of the correct LUT.
|
||||
// The property change allowance for the meter size and pressure assembled has to be set in advance
|
||||
// soon the production process is defined as assembly.
|
||||
Meter.EnablePropertyChangeAbility(true);
|
||||
if (!Meter.SetMeterSize((MeterSize)orderDetails.MeterSize))
|
||||
{
|
||||
ErrorMsgDispatcher(Resources.StrErrorMsgChangingMeterSizeFromOrderFailed);
|
||||
return StatusReturn.Failed;
|
||||
}
|
||||
SuccessMsgDispatcher(Resources.StrSuccessMsgChangedMeterSizeFromOrder + $": {Meter.MeterSize}");
|
||||
|
||||
if (!Meter.SetPressureSensorAssembled(orderDetails.PressurePresent))
|
||||
{
|
||||
ErrorMsgDispatcher(Resources.StrErrorMsgPressureSensorSetupFromOrderFailed);
|
||||
return StatusReturn.Failed;
|
||||
}
|
||||
var pressurePresent = Meter.PressureSensorAssembled
|
||||
? Resources.StrMsgPressureSensorApplied
|
||||
: Resources.StrMsgPressureSensorNotApplied;
|
||||
SuccessMsgDispatcher(Resources.StrSuccessMsgPressureSensorSetupFromOrder + $": {pressurePresent}");
|
||||
Meter.EnablePropertyChangeAbility(false);
|
||||
|
||||
return StatusReturn.Okay;
|
||||
}
|
||||
}
|
||||
|
||||
+8
-12
@@ -121,9 +121,9 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.Picki
|
||||
productionProcessNo: 2,
|
||||
nextStateOnSuccess: ProcessState.CheckCordonelMapping),
|
||||
|
||||
// Precondition: - The connection process has to be completed as a readout of some register
|
||||
// values from the Cordonel are needed to check the update capability:
|
||||
// - Wait on completed connection process before starting this process.
|
||||
// Precondition: - The connection process has to be completed
|
||||
// This process is needed to load the radio signal levels for this meter size and length which have to
|
||||
// be compared later in the 'CheckProductionState' process.
|
||||
new ProcessStateStruct(
|
||||
productionProcess: new GetFinalParametrization(Resources.StrStateGetProgrammingParameters),
|
||||
processState: ProcessState.GetProgrammingParameters,
|
||||
@@ -142,19 +142,16 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.Picki
|
||||
productionProcessNo: 0,
|
||||
nextStateOnSuccess: ProcessState.DetectCordonel),
|
||||
|
||||
// Connection of Cordonel has to be completed before assigning next state, so leave to automatic
|
||||
// to change the state after successfully execution. Meter has to be connected in advance being able to
|
||||
// overwrite the meter size based on the order details. The initial meter size in connect Cordonel will
|
||||
// be set by reading the Cordonel out. But a new meter size may be forced by the order needed to change
|
||||
// it and install the correct LUT
|
||||
// Precondition: - The connection process has to be completed
|
||||
// During the 'ConnectCordonel' process the meter size will be read from the meter and set inside the
|
||||
// 'GenesisMeter' object. Based on the order details this has to be changed afterward and to overwrite
|
||||
// this in the 'GenesisMeter' object. It is needed for the installation of the correct LUT.
|
||||
new ProcessStateStruct(
|
||||
productionProcess: new CheckCordonelMapping(Resources.StrStateCheckCordonelMapping),
|
||||
processState: ProcessState.CheckCordonelMapping,
|
||||
processInfo: Resources.StrStateCheckCordonelMapping,
|
||||
productionProcessNo: 3,
|
||||
nextStateOnSuccess: ProcessState.GetProgrammingParameters,
|
||||
// Wait before starting this process until this process has been successfully completed
|
||||
waitForSingleProcess: ProcessState.ConnectCordonel),
|
||||
nextStateOnSuccess: ProcessState.GetProgrammingParameters),
|
||||
|
||||
// Connection of Cordonel has to be completed so leave to automatic
|
||||
new ProcessStateStruct(
|
||||
@@ -191,7 +188,6 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.Picki
|
||||
productionProcessNo: null,
|
||||
nextStateOnSuccess: ProcessState.Idle),
|
||||
|
||||
//TODO Roland: implement your states here
|
||||
#endregion -------------------------------- PICKING-STATES --------------------------------------------
|
||||
|
||||
};
|
||||
|
||||
@@ -1064,7 +1064,7 @@ namespace Xylem.Common.Production.ProductionUiCordonel
|
||||
srLine.Contains(Properties.Resources.StrProcessStateDone) ||
|
||||
srLine.Contains(Properties.Resources.StrProcessStateWarning) ||
|
||||
srLine.Contains(Properties.Resources.StrProcessStateSkipped) ||
|
||||
srLine.Contains(Properties.Resources.StrWarningMsgSpecialRequirementActive))
|
||||
srLine.Contains(Properties.Resources.StrProcessStateAttention))
|
||||
compressedSb.AppendLine(srLine);
|
||||
srLine = sr.ReadLine();
|
||||
}
|
||||
|
||||
@@ -150,6 +150,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ATTENTION: Special requirement setup and approved for production.
|
||||
/// </summary>
|
||||
internal static string StrAttentionMsgSpecialRequirementActive {
|
||||
get {
|
||||
return ResourceManager.GetString("StrAttentionMsgSpecialRequirementActive", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Done.
|
||||
/// </summary>
|
||||
@@ -411,6 +420,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR: The meter size setup failed.
|
||||
/// </summary>
|
||||
internal static string StrErrorMsgChangingMeterSizeFromOrderFailed {
|
||||
get {
|
||||
return ResourceManager.GetString("StrErrorMsgChangingMeterSizeFromOrderFailed", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR: Check radio encryption key failed.
|
||||
/// </summary>
|
||||
@@ -555,6 +573,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR: This Cordonel is assigned to another production order.
|
||||
/// </summary>
|
||||
internal static string StrErrorMsgMeterForOtherOrderAssigned {
|
||||
get {
|
||||
return ResourceManager.GetString("StrErrorMsgMeterForOtherOrderAssigned", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR: Cordonel length is unknown.
|
||||
/// </summary>
|
||||
@@ -591,6 +618,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR: This Cordonel cannot be mapped to an order.
|
||||
/// </summary>
|
||||
internal static string StrErrorMsgMissingMappingInformation {
|
||||
get {
|
||||
return ResourceManager.GetString("StrErrorMsgMissingMappingInformation", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Missing Network Connection. The software is going to exit!.
|
||||
/// </summary>
|
||||
@@ -600,6 +636,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR: Unable to acquire order information for this Cordonel.
|
||||
/// </summary>
|
||||
internal static string StrErrorMsgMissingOrderInformation {
|
||||
get {
|
||||
return ResourceManager.GetString("StrErrorMsgMissingOrderInformation", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR: Collection of order details failed.
|
||||
/// </summary>
|
||||
@@ -672,6 +717,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR: The pressure sensor setup failed.
|
||||
/// </summary>
|
||||
internal static string StrErrorMsgPressureSensorSetupFromOrderFailed {
|
||||
get {
|
||||
return ResourceManager.GetString("StrErrorMsgPressureSensorSetupFromOrderFailed", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR.
|
||||
/// </summary>
|
||||
@@ -1473,6 +1527,24 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Pressure sensor assembled.
|
||||
/// </summary>
|
||||
internal static string StrMsgPressureSensorApplied {
|
||||
get {
|
||||
return ResourceManager.GetString("StrMsgPressureSensorApplied", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Pressure sensor not assembled.
|
||||
/// </summary>
|
||||
internal static string StrMsgPressureSensorNotApplied {
|
||||
get {
|
||||
return ResourceManager.GetString("StrMsgPressureSensorNotApplied", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Generate password file.
|
||||
/// </summary>
|
||||
@@ -1626,6 +1698,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ATTENTION.
|
||||
/// </summary>
|
||||
internal static string StrProcessStateAttention {
|
||||
get {
|
||||
return ResourceManager.GetString("StrProcessStateAttention", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Check for new Cordonel.
|
||||
/// </summary>
|
||||
@@ -2121,6 +2202,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Success: The meter size is set up correctly.
|
||||
/// </summary>
|
||||
internal static string StrSuccessMsgChangedMeterSizeFromOrder {
|
||||
get {
|
||||
return ResourceManager.GetString("StrSuccessMsgChangedMeterSizeFromOrder", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Success: Successfully compared.
|
||||
/// </summary>
|
||||
@@ -2166,6 +2256,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Success: The pressure sensor is set up correctly.
|
||||
/// </summary>
|
||||
internal static string StrSuccessMsgPressureSensorSetupFromOrder {
|
||||
get {
|
||||
return ResourceManager.GetString("StrSuccessMsgPressureSensorSetupFromOrder", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Success.
|
||||
/// </summary>
|
||||
@@ -2355,6 +2454,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to WARNING: This Cordonel is already assigned to this production order.
|
||||
/// </summary>
|
||||
internal static string StrWarningMsgCordonelIsAlreadyMarried {
|
||||
get {
|
||||
return ResourceManager.GetString("StrWarningMsgCordonelIsAlreadyMarried", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to WARNING: Inspect results.
|
||||
/// </summary>
|
||||
@@ -2372,14 +2480,5 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
return ResourceManager.GetString("StrWarningMsgRepeatedAccumulatorReset", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ATTENTION: Special requirement setup and approved for production.
|
||||
/// </summary>
|
||||
internal static string StrWarningMsgSpecialRequirementActive {
|
||||
get {
|
||||
return ResourceManager.GetString("StrWarningMsgSpecialRequirementActive", resourceCulture);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
File diff suppressed because it is too large
Load Diff
File diff suppressed because it is too large
Load Diff
@@ -197,10 +197,6 @@
|
||||
<Reference Include="System.Configuration" />
|
||||
<Reference Include="System.Core" />
|
||||
<Reference Include="System.Xml" />
|
||||
<Reference Include="Xylem.Common.Hardware.Interfaces.Ports.SerialPorts, Version=1.1.2.7, Culture=neutral, processorArchitecture=MSIL">
|
||||
<SpecificVersion>False</SpecificVersion>
|
||||
<HintPath>..\..\Hardware\Interfaces\Ports\SerialPorts\bin\Debug\Xylem.Common.Hardware.Interfaces.Ports.SerialPorts.dll</HintPath>
|
||||
</Reference>
|
||||
</ItemGroup>
|
||||
<ItemGroup>
|
||||
<Compile Include="..\..\.shared\SharedAssemblyInfo.cs">
|
||||
|
||||
Reference in New Issue
Block a user