Files
laatzen/Common/Hardware/WaterMeter/Genesis/MockGenesis/MockGenesis.cs
T

1129 lines
48 KiB
C#

using System;
using System.Collections.Generic;
using System.IO;
using System.Linq;
using System.Reflection;
using NCrunch.Framework;
using Xylem.Common.CommonCore.Consts;
using Xylem.Common.Hardware.WaterMeter.Genesis.Applications;
using Xylem.Common.Hardware.WaterMeter.Genesis.Applications.Const;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisFile;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers.DataTypes;
using Xylem.Common.Logic.ProductionOrderCore.OrderData;
using Xylem.Common.Logic.ProductionOrderCore.TestResults;
namespace Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis
{
/// <summary>
/// Mock Genesis for usage to simulate an original Genesis without any hardware:
/// - The communication will use buffers program internally instead a physical port,
/// - Login, Logout and all other operations will NOT use a database call.
/// </summary>
public class MockGenesis : GenesisMeter
{
#region -------------------------------- Properties -----------------------------------------------------------
/// <summary>
/// The application description file (ADF) will be used to install a simulated new firmware to
/// the mock Genesis
/// </summary>
private String _packageDescriptionFile = DefaultPackageDescriptionFile;
/// <summary>
/// The required mock firmware installation is based on the file application simulation an installation
/// based on the package description file.
/// </summary>
private List<FileApplications> _mockFw = new List<FileApplications>();
/// <summary>
/// A list of all config registers for debug.
/// </summary>
// ReSharper disable once CollectionNeverQueried.Local for DEBUG only
private readonly List<String> _configRegisterNames = new List<String>();
/// <summary>
/// A list of all FLASH registers for debug.
/// </summary>
// ReSharper disable once CollectionNeverQueried.Local for DEBUG only
private readonly List<String> _flashRegisterNames = new List<String>();
/// <summary>
/// Simulated permanent storage (FLASH memory) to keep the values set with store configuration.
/// </summary>
private readonly MeterRegisters _flashRegister = new MeterRegisters();
/// <summary>
/// A list of all known registers which do not return the written value.
/// EXAMPLES:
/// - SENSUSRADIO_SystemState writing 0xFF returns 0x02
/// - XXX_StoreConfiguration writing 0x01 returns 0x00
///
/// The registers can be fully qualified or contain a substring like _StoreConfiguration if it always
/// returns an identical reply!
///
/// The first value is the expected value which will be searched for and the second value is the reply!
/// Only it the first value is exact as described here the reply is going to be changed.
///
/// </summary>
private static readonly List<RecoveryRegisterItem> SpecialRegisterReplies = new List<RecoveryRegisterItem>
{
// (partial) name expected value reply value
new RecoveryRegisterItem("SENSUSRADIO_SystemState", new Byte[]{0xFF}, new Byte[]{0x02}),
new RecoveryRegisterItem("_StoreCalibration", new Byte[]{0x01}, new Byte[]{0x00}),
new RecoveryRegisterItem("_StoreConfiguration", new Byte[]{0x01}, new Byte[]{0x00})
};
/// <summary>
/// A list of all known registers to trigger a rest of the input bit.
/// EXAMPLES:
/// - CUSTOMER_TriggerAlarmCancel register value
/// before input 0000 0001 0001 1111
/// new reset input 0000 1111 1111 0000
/// output 0000 0000 0000 1111
///
/// </summary>
private static readonly List<RecoveryRegisterItem> SpecialRegisterResetBits = new List<RecoveryRegisterItem>
{
// (partial) name placeholder for input and output
new RecoveryRegisterItem("CUSTOMER_TriggerAlarmCancel", new Byte[4]),
};
/// <summary>
/// The root path for all mock FwPackaged.
/// </summary>
private const String RootMockFwPath = "MockFwExamples";
/// <summary>
/// Mock object can overwrite PcbId for test purposes and set password to null to avoid
/// usage of wrong password and lock of the device trying to log in with the wrong password
/// </summary>
public new String PcbId
{
set
{
base.PcbId = value;
ClearPassword();
}
get => base.PcbId;
}
/// <summary>
/// Mock object can overwrite LutCrc for test purposes
/// </summary>
public new String LutCrc
{
set => base.LutCrc = value;
get => base.LutCrc;
}
/// <summary>
/// Mock object can overwrite StrCoreRevision for test purposes
/// </summary>
public new String StrCoreRevision
{
set => base.StrCoreRevision = value;
get => base.StrCoreRevision;
}
/// <summary>
/// Mock object can overwrite CoreRevision for test purposes
/// </summary>
public new Int32? CoreRevision
{
set => base.CoreRevision = value;
get => base.CoreRevision;
}
/// <summary>
/// Mock object can overwrite RadioFrequencyMhz for test purposes
/// </summary>
public new Int32? RadioFrequencyMhz
{
set => base.RadioFrequencyMhz = value;
get => base.RadioFrequencyMhz;
}
/// <summary>
/// Mock object can overwrite InstalledFwVersion for test purposes
/// </summary>
public new UInt32? InstalledFwVersion
{
set => base.InstalledFwVersion = value;
get => base.InstalledFwVersion;
}
/// <summary>
/// Mock object can overwrite Region for test purposes
/// </summary>
public new String Region
{
set => base.Region = value;
get => base.Region;
}
/// <summary>
/// Mock object can overwrite MeterSize for test purposes
/// </summary>
public new String MeterSize
{
private set => base.MeterSize = value;
get => base.MeterSize;
}
/// <summary>
/// Mock object can overwrite length for test purposes
/// </summary>
public new String MeterLength
{
set => base.MeterLength = value;
get => base.MeterLength;
}
/// <summary>
/// Mock object can overwrite pressure sensor is assembled for test purposes
/// </summary>
public new Boolean PressureSensorAssembled
{
private set => base.PressureSensorAssembled = value;
get => base.PressureSensorAssembled;
}
/// <summary>
/// Mock object can overwrite FwVersion for test purposes
/// </summary>
public new String FwVersion
{
private set => base.FwVersion = value;
get => base.FwVersion;
}
/// <summary>
/// Mock object can overwrite login status for test purposes
/// </summary>
public new Boolean IsLoggedOn
{
set => base.IsLoggedOn = value;
get => base.IsLoggedOn;
}
/// <summary>
/// The exec path of the assembly for debug in environment.
/// </summary>
private readonly String _assemblyExecRootPath = Path.GetDirectoryName(Assembly.GetExecutingAssembly().Location);
/// <summary>
/// Fw package path relative to solution main folder.
/// </summary>
private readonly String _mockFwPackageRootPath;
#endregion ----------------------------- Properties -----------------------------------------------------------
#region --------------------------------- Default package description file ------------------------------------
/// <summary>
/// This file will be used to assign the default MeterApplications as simulated installation to the Genesis
/// meter. It contains only the important information:
/// - Each line starting with "Id" is an App,
/// - the "Maximum supported core revision" will be used as CoreRevision.
/// </summary>
private const String DefaultPackageDescriptionFile =
"Id 0x00, CRC16 0x39A8, size 37972 bytes, version 5.37\r\n" +
"Id 0x01, CRC16 0xB16C, size 3112 bytes, version 0.70\r\n" +
"Id 0x04, CRC16 0x8290, size 7944 bytes, version 2.38\r\n" +
"Id 0x08, CRC16 0x12D4, size 3972 bytes, version 0.18\r\n" +
"Id 0x11, CRC16 0x5796, size 12412 bytes, version 0.75\r\n" +
"Id 0x10, CRC16 0x0704, size 93488 bytes, version 5.30\r\n" +
"Id 0x0F, CRC16 0xA3A6, size 25164 bytes, version 3.02\r\n" +
"Id 0x09, CRC16 0xD56D, size 6196 bytes, version 1.59\r\n" +
"Id 0x12, CRC16 0x9BA6, size 7948 bytes, version 1.13\r\n" +
"Id 0x14, CRC16 0x2EB1, size 23324 bytes, version 2.06\r\n" +
"Id 0x15, CRC16 0x43F4, size 6808 bytes, version 0.59\r\n" +
"Id 0x18, CRC16 0xB2D5, size 116 bytes, version 13.0B\r\n" +
"Maximum supported core revision: \"Cordonel 1.78\"";
#endregion ------------------------------ Default package description file ------------------------------------
#region -------------------------------- Class handling -------------------------------------------------------
/// <summary>
/// Standard Ctor
/// </summary>
public MockGenesis()
{
var subFolder = Path.Combine("Hardware", "WaterMeter", "Genesis", "MockGenesis");
var solutionPath = "";
if (NCrunchEnvironment.NCrunchIsResident())
{
solutionPath = NCrunchEnvironment.GetOriginalSolutionPath().Replace("Common.sln", "");
}
else
{
if (_assemblyExecRootPath != null)
{
// We are in the Unit test folder "..\Common\Production\ProductionUiCordonel.UnitTests\bin\Debug"
// and need to go back to "..\Common"
var directoryInfo = Directory.GetParent(_assemblyExecRootPath)?.Parent?.Parent?.Parent?.Parent;
if (directoryInfo != null)
{
solutionPath = directoryInfo.FullName;
}
}
}
_mockFwPackageRootPath = Path.Combine(solutionPath, subFolder, "MockFwExamples");
Console.WriteLine($@"MOCK GENESIS: Search path for MockFwExamples: {_mockFwPackageRootPath}");
}
#endregion
#region -------------------------------- Firmware update and modification -------------------------------------
/// <summary>
/// Install a new firmware to the mock with the package description file as serialized string
/// <see cref="DefaultPackageDescriptionFile"/> which is reduced to the important lines or alternative
/// a named FW Version string like "R1.3.0B" or "R130B" which has to be part of the MockFwExamples.
///
/// The filters to find the path in the root path is the region and FW release version
/// "EMEA" or "NA"
/// "R130B" or "R1.3.0B"
/// additional naming is allowed (e.g. "EMEA_R13F3_replaces_R1107_R1108")
///
/// The filters to accept the file is:
/// "product" and
/// ".txt"
/// additional naming is allowed (e.g. "rowproduct_R130B.txt")
///
/// The FW root path is the path where the FW update packages are stored.
/// All files needed to be stored directly in the main folder of the FW version:
///
/// EXAMPLE:
/// [Root path]\EMEA_R130B\rowproduct_xyz.txt (package description file, mandatory is "product" and ".txt")
/// \configuration.json
/// \binfile00_0537_xyz.bin (package description file, mandatory is "binfile" and ".bin")
/// \binfile01_0070_xyz.bin
/// \...
/// \binfile18_130B_xyz.bin
/// [Root path]\NA_R2006 \naproduct_xyz.txt (package description file, mandatory is "product" and ".txt")
/// \configuration.json
/// \binfile00_0533_xyz.bin (package description file, mandatory is "binfile" and ".bin")
/// \binfile01_0068_xyz.bin
/// \...
/// \binfile18_2006_xyz.bin
///
/// </summary>
/// <param name="packageDescriptionFile"></param>
/// <param name="fwName">if this is null, the description file will be installed</param>
/// <remarks date="2024-Dec-02" author="Thomas Wiedebusch">
/// - Initial
/// </remarks>
/// <remarks date="2024-Dec-12" author="Thomas Wiedebusch">
/// - Logout, clear FLASH, login.
/// </remarks>
/// <remarks date="2024-Dec-18" author="Thomas Wiedebusch">
/// - Take FW version from MockFwExamples if explicit named with the release string.
/// </remarks>
/// <remarks date="2024-Dec-19" author="Thomas Wiedebusch">
/// - Returns bool.
/// </remarks>
public Boolean InstallNewMockFw(String packageDescriptionFile = null, String fwName = null)
{
if (fwName != null)
{
var releaseName = FwVersion.Replace(".", "");
if (!FwVersion.Equals(fwName) && !releaseName.Contains(fwName))
{
//Load new rawproduct.txt or naproduct.txt and install it to MockGenesis
if (!MeterFwUpdate.LoadPackageFile(_mockFwPackageRootPath, fwName, out _packageDescriptionFile))
return false;
}
}
else if (packageDescriptionFile != null)
{
// Set the new package file which will be parsed and used as simulation for all installed
// applications
_packageDescriptionFile = packageDescriptionFile;
}
else
{
return false;
}
Logout();
_flashRegister.MeterRegisterDic.Clear();
_flashRegisterNames.Clear();
// Force re-generation of the meter app and config register lists
MeterAppListVersion.Clear();
ConfigRegister.MeterRegisterDic.Clear();
ConfigApplications.Clear();
// Login to build initial registers being able to use the FLASH register dictionary immediately.
Login();
return RebootGenesis() == StatusReturn.Okay;
}
/// <summary>
/// Prepare the mock installed firmware by parsing the package description file.
/// </summary>
/// <remarks date="2024-Dec-01" author="Thomas Wiedebusch">
/// - Initial
/// </remarks>
private void ParsePackageDescriptionFile()
{
if (string.IsNullOrEmpty(_packageDescriptionFile))
return;
if (_mockFw == null)
_mockFw = new List<FileApplications>();
_mockFw.Clear();
MeterFwUpdate.GetPackageFileApplications(_packageDescriptionFile, _mockFw);
CoreRevision = MeterFwUpdate.GetCoreRevisionMax(_packageDescriptionFile);
if (CoreRevision != null)
StrCoreRevision = BuildFwVersionStringFromDec(CoreRevision);
}
/// <summary>
/// Modify or erase one mock app to simulate an application error of the firmware package.
/// This will be used for test purposes to manually change installed app-properties.
///
/// REMIND: All Apps are required to stay in MeterAppListVersion as this is a list of all Apps found in the
/// configuration.json. Does mean, for erasure just change the status to
/// <see cref="MeterAppState.MeterAppNotInstalled"/> !
///
/// </summary>
/// <param name="appId"></param>
/// <param name="version">null doesn't change actual version</param>
/// <param name="crc">null doesn't change actual CRC</param>
/// <param name="eraseApp"></param>
/// <returns>true if modification could be done</returns>
/// <remarks date="2024-Dec-04..05" author="Thomas Wiedebusch">
/// - Initial
/// </remarks>
public Boolean ModifyMockApp(Byte appId, UInt32? version = null, UInt16? crc = null, Boolean eraseApp = false)
{
if (MeterAppListVersion == null ||
MeterAppListVersion.Count == 0 ||
MeterAppListVersion.All(app => app.AppId != appId))
return false;
Logout();
foreach (var app in MeterAppListVersion.Where(app => app.AppId == appId))
{
if (eraseApp)
{
app.IsInstalled = false;
app.Status = MeterAppState.MeterAppNotInstalled;
app.StrVersion = "0.0";
app.Version = 0;
}
if (version != null)
{
app.Version = (UInt32)version;
app.StrVersion = BuildFwVersionStringFromDec((Int32?)version);
}
if (crc != null)
{
app.Crc = (UInt16)crc;
}
}
return true;
}
#endregion ----------------------------- Firmware update and modification -------------------------------------
#region -------------------------------- Mock Genesis Initialization ------------------------------------------
/// <summary>
/// Mock reading all applications from a predefined package description file instead from the Meter.
/// </summary>
/// <remarks date="2024-Dec-01" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
/// <remarks date="2025-Jun-19" author="Thomas Wiedebusch">
/// - Avoid overwriting of list combined with valid register dictionary.
/// </remarks>
/// <remarks date="2025-Aug-07" author="Thomas Wiedebusch">
/// - Check interface compatibility.
/// </remarks>
protected override void ReadMeterFirmwareAndAssignRegisters()
{
// Avoid overwriting of list if this already exits
if (MeterAppListVersion.Any() && MeterAppListVersion.All(f => f.Status != MeterAppState.Unknown) &&
ConfigRegister.MeterRegisterDic.Count != 0)
{
Logger.Warn($"Slot:{Slot} - Trying to overwride installed FW. Skipping generation of new " +
"App list and meter register dictionary");
return;
}
// This loads the configuration.json from the exec directory
LoadConfiguration(Path.Combine(Path.GetDirectoryName(Assembly.GetExecutingAssembly().Location)));
// Simulate a firmware installation using the package description file to assign applications
ParsePackageDescriptionFile();
// Use the _mockFw created out of the package description file and which is a file application list
if (_mockFw == null || _mockFw.Count < MeterFwUpdate.MinAppsRequiredForOperation)
{
return;
}
UInt32 interfaceMaxEmeaVersion = 0;
UInt32 interfaceMaxNaVersion = 0;
var strInterfaceMaxEmeaVersion = "";
var strInterfaceMaxNaVersion = "";
//Get all existing applications from meter register dictionary
foreach (var meterApp in ConfigApplications.OrderBy(o => o.AppId))
{
if (meterApp.AppName.Equals("OPTICALINTERFACE"))
{
// Build the interface id for information of compatibility from FW to configuration.json
InterfaceVersion = BuildFwVersionStringFromDec(meterApp.AppVersion);
// Build the max supported versions for EMEA and NA to check the supported FW
strInterfaceMaxEmeaVersion = BuildFlexnetFwVersion(out interfaceMaxEmeaVersion,
meterApp.InterfaceMaxEmeaVersion);
strInterfaceMaxNaVersion = BuildFlexnetFwVersion(out interfaceMaxNaVersion,
meterApp.InterfaceMaxNaVersion);
continue;
}
// Take all listed config apps even if not installed
var app = new MeterApplications
{
AppId = meterApp.AppId,
Version = 0,
StrVersion = "0.00",
AppName = meterApp.AppName,
Crc = 0x0000,
Status = MeterAppState.MeterAppNotInstalled,
IsInstalled = false
};
foreach (var fileApp in _mockFw)
{
if (fileApp.AppId == meterApp.AppId)
{
app.Version = fileApp.Version;
app.StrVersion = fileApp.StrVersion;
app.Crc = fileApp.Crc;
app.Status = MeterAppState.MeterAppUpToDate;
app.IsInstalled = true;
}
// The FLEXNETVERSION is the overall firmware version
if (fileApp.AppId == MeterFwUpdate.FlexnetVersionAppId)
{
InstalledFwVersion = fileApp.Version;
FwVersion = fileApp.StrVersion;
}
}
MeterAppListVersion.Add(app);
}
try
{
// Initial list of ALL registers defined in configuration.json read from local bin directory
var tempConfigRegisters = ConfigRegister.MeterRegisterDic.ToList();
// Reduce registers to valid registers for a specific application with a specific version
// The old register dictionary is going to be cleared automatically calling this method.
BuildValidMeterRegisters(tempConfigRegisters);
// Fill the meter register dictionary with defaults are stored values in simulated FLASH memory
InitConfigAndFlashRegisters();
// Check for SENSUSRADIO as indication for region "EMEA", else it is regin "NA"
Region = "NA";
if (ConfigRegister.MeterRegisterDic.Any(app => app.Key.AppName.Equals("SENSUSRADIO")))
{
var value = ConfigRegister.Get("SENSUSRADIO_FrequencyIndicator");
if (value != null)
{
RadioFrequencyMhz = RegisterConverter.ByteArrayToValue<Int32>(value);
Region = "EMEA";
}
}
// Assign the max supported FW version of the interface depending on the region
if (Region.Equals("EMEA"))
InterfaceMaxFwVersion = strInterfaceMaxEmeaVersion;
if (Region.Equals("NA"))
InterfaceMaxFwVersion = strInterfaceMaxNaVersion;
// Check if the interface supports the FW
if (InstalledFwVersion != null &&
((Region.Equals("EMEA") && interfaceMaxEmeaVersion >= InstalledFwVersion) ||
(Region.Equals("NA") && interfaceMaxNaVersion >= InstalledFwVersion)))
{
InterfaceSupportsFwVersion = true;
Logger.Info($"Slot:{Slot} - Interface supports FW version: {FwVersion}");
}
else
{
InterfaceSupportsFwVersion = false;
Logger.Warn($"Slot:{Slot} - Interface does not support FW version! Installed FW version: {FwVersion}, " +
$"Interface supports max FW version: {InterfaceMaxFwVersion}");
}
}
catch (Exception ex)
{
Logger.Error($"Slot:{Slot} - {ex.Message}");
}
}
/// <summary>
/// Use the app name to flash all contents:
/// - Take all values from RAM memory (config register dictionary) and copy it to FLASH memory (flash
/// register dictionary) which simulates the non-volatile memory of the Genesis.
/// </summary>
/// <param name="appName"></param>
/// <remarks date="2024-Dec-03" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
private void FlashMemory(String appName)
{
if (_flashRegister == null || ConfigRegister == null)
{
return;
}
// Safe all data from config to FLASH register dictionary for App.
foreach (var reg in ConfigRegister.MeterRegisterDic)
{
try
{
var regName = reg.Key.GetIdent();
// Filter for all registers of a specific App
if (regName.Contains(appName))
{
// Avoid writing of NOT writable registers, only read write makes sense as others cannot be
// read back!
if (reg.Key.RegisterDetail.Privilege.Lvl8 == Access.RW &&
reg.Key.DataType != typeof(Rpc))
{
var flashData = ConfigRegister.Get(regName);
// Throws an exception if register doesn't exist, but we want to go ahead with the others
var regDef = _flashRegister.GetRegisterDefinitionByName(regName);
_flashRegister.Set(regDef, flashData);
}
}
}
catch (Exception ex)
{
Logger.Error($"Slot:{Slot} - {ex.Message}");
}
}
}
/// <summary>
/// Store one single parameter to flash memory to simulate FW internal change of register or the
/// "GENESISFLOW_StoreCalibration":
/// - Avoid to check of RO or WO to force an update as it would be done by the FW.
/// </summary>
/// <param name="regName"></param>
/// <remarks date="2024-Dec-07" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
private void SingleParameterFlashMemory(String regName)
{
if (_flashRegister == null)
{
return;
}
try
{
var flashData = ConfigRegister.Get(regName);
// Throws an exception if register doesn't exist, but we want to go ahead with the others
var regDef = _flashRegister.GetRegisterDefinitionByName(regName);
_flashRegister.Set(regDef, flashData);
}
catch (Exception ex)
{
Logger.Error($"Slot:{Slot} - {ex.Message}");
}
}
/// <summary>
/// Fill the meter register dictionary with the stored values of the simulated FLASH memory:
/// - If FLASH memory register dictionary doesn't exist (initial start) generate a copy of
/// the config register dictionary and fill it with default values from configuration.json,
/// - Copy ALWAYS the content of the FLASH to the config register dictionary.
///
/// REMIND:
/// If an application has received a store configuration, the FLASH content will be overwritten
/// from default value to the actual value of the config register dictionary as this is the
/// temporary value (RAM simulation) of the Genesis.
///
/// </summary>
/// <remarks date="2024-Dec-03..10" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
private void InitConfigAndFlashRegisters()
{
if (_flashRegister == null || ConfigRegister == null)
{
return;
}
_configRegisterNames.Clear();
// If the FLASH registers do not exist, create those and fill it with default values
if (_flashRegister.MeterRegisterDic.Count == 0)
{
foreach (var reg in ConfigRegister.MeterRegisterDic)
{
var regName = reg.Key.GetIdent();
_flashRegisterNames.Add(regName);
var regDef = ConfigRegister.GetRegisterDefinitionByName(regName);
// First clone entire register set to avoid exception if register is not available
_flashRegister.MeterRegisterDic.TryAdd(reg.Key, null);
// Avoid writing of NOT writable registers
if (reg.Key.RegisterDetail.Privilege.Lvl8 == Access.RW) // && reg.Key.DataType != typeof(Rpc))
{
// Add default value to FLASH register dictionary
RegisterConverter.SetToDefault(regDef, out var value);
_flashRegister.Set(regDef, value);
}
}
_flashRegisterNames.Sort();
}
// Preset at initial login after start or reboot all config registers with the FLASH register values.
// Those are set to default on initial start and after store configuration on a predefined value.
foreach (var reg in ConfigRegister.MeterRegisterDic)
{
try
{
var regName = reg.Key.GetIdent();
_configRegisterNames.Add(regName);
var regDef = ConfigRegister.GetRegisterDefinitionByName(regName);
// Avoid writing of NOT writable registers, only read write makes sense as others cannot be read
// back!
if (reg.Key.RegisterDetail.Privilege.Lvl8 == Access.RW) //&& reg.Key.DataType != typeof(Rpc))
{
var flashData = _flashRegister.Get(regName);
// Throws an exception if register doesn't exist, but we want to go ahead with the others
ConfigRegister.Set(regDef, flashData);
}
}
catch (Exception ex)
{
Logger.Error($"Slot:{Slot} - {ex.Message}");
}
_configRegisterNames.Sort();
}
}
#endregion ----------------------------- Mock Genesis Initialization ------------------------------------------
#region -------------------------------- Mock Genesis Simulation ----------------------------------------------
/// <inheritdoc />
/// <summary>
/// Simulate login to mock Genesis for test purposes
/// </summary>
/// <remarks date="2024-Nov-28" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public override Boolean Login()
{
ReadMeterFirmwareAndAssignRegisters();
IsLoggedOn = true;
return IsLoggedOn;
}
/// <inheritdoc />
/// <summary>
/// Simulate logout to mock Genesis for test purposes
/// </summary>
/// <remarks date="2024-Nov-28" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public override Boolean Logout()
{
IsLoggedOn = false;
return IsLoggedOn;
}
/// <inheritdoc />
/// <summary>
/// Set the meter size if previously unlocked.
/// - MockGenesis allows additional empty string or question mark string!
/// </summary>
/// <param name="meterSize">true if setting is allowed</param>
/// <returns>true if possible</returns>
public override Boolean SetMeterSize<T>(T meterSize)
{
if (!UnlockEssentialProperties)
return false;
if (meterSize is String)
{
var ms = meterSize.ToString();
// MockGenesis allows 'killing' of MeterSize
if (Equals(meterSize,"") || Equals(meterSize,"?"))
{
}
else if (Logic.ProductionOrderCore.OrderData.MeterSize.NA == MeterSizeConverter.ConvertMeterSizeNameToEnum(ms))
{
return false;
}
MeterSize = ms;
}
else if (meterSize.GetType() == typeof(MeterSize))
{
var ms = Convert.ToInt32(meterSize);
MeterSize = MeterSizeConverter.ConvertMeterSizeEnumToSizeName((MeterSize)ms);
}
else // Type is unknown
{
return false;
}
return true;
}
/// <inheritdoc />
/// <summary>
/// Simulate login with password to mock Genesis for test purposes
/// </summary>
/// <remarks date="2024-Nov-28" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public override Boolean Login(String password, Boolean runImmediately = true,
Boolean skipReadMeterFwAndAssignRegisters = false)
{
Password = password;
return Login();
}
/// <summary>
/// Mock Write Register:
/// - Optional: wait for result and validate.
/// </summary>
/// <typeparam name="T">Data type of Register</typeparam>
/// <param name="regName">Register to change</param>
/// <param name="value">Value to save</param>
/// <param name="waitForResult">wait until result is ready</param>
/// <param name="checkRegister">check the content of the register by read back</param>
/// <param name="skipRetryErrorCode">skip retries on this error code return</param>
/// <returns>true on successful operation</returns>
/// <remarks date="2024-Dec-02..03" author="Thomas Wiedebusch">
/// - Initial mock implementation.
/// </remarks>
/// <remarks date="2024-Dec-10" author="Thomas Wiedebusch">
/// - Capture "SYSTEM_TriggerUpgrade" to force a reboot and install the FW defined in the actual FW package
/// description file.
/// - Store calibration executed on calibration registers.
/// </remarks>
public override Boolean WriteRegister<T>(String regName, T value, Boolean waitForResult = true,
Boolean checkRegister = false, UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode)
{
try
{
var regDef = ConfigRegister.GetRegisterDefinitionByName(regName);
var data = RegisterConverter.ValueToByteArray(value);
var hideDataInLog = regDef.RegisterName.Contains("EncryptionKey") ||
regDef.RegisterName.Contains("Password");
var rawMsg = RegisterConverter.GetRegisterRawText(regDef, data, hideDataInLog);
Logger.Info($"Slot:{Slot} - Write register({regDef.GetIdent()}), record({rawMsg})");
// Check for special response for predefined registers which reply with a changed
// parameter like SENSUSRADIO_SystemState set to 0xFF creates a reply of 0x02.
// This has to be done BEFORE ConfigRegister.Set!
CheckAndModifySpecialReplies(regName, data);
// Avoid writing of NOT writable registers and out of range of register value
if (!PreRegisterWrite(regDef, data))
return false;
// Throws an exception if register doesn't exist
ConfigRegister.Set(regDef, data);
// For mock simulation the write register is going to kick-off special activities
CheckSpecialActivities(regName, value);
// If no further action like check register or read-back is required, exit here with success
if (!waitForResult && !checkRegister)
{
return true;
}
// If register check by read back is not required we return the acknowledgment state
if (!checkRegister || regDef.RegisterDetail.Privilege.Lvl8 == Access.WO)
{
return true;
}
var readBackData = ReadRegister(regName, data.Length, skipRetryErrorCode);
if (readBackData == null)
return false;
// Check if register read was okay and read and written data are EQUAL
for (var i = 0; i < data.Length; i++)
{
if (readBackData[i] != data[i])
return false;
}
return true;
}
catch (Exception e)
{
Logger.Error($"Slot:{Slot} - {e.Message}");
}
return false;
}
/// <summary>
/// Check for special activities needed to execute on register write access:
/// - Store configuration to safe all values of a single App to the simulated FLASH memory,
/// - Store calibration stores all defined register <see cref="CalibrationResults.CalibrationRegisterNames"/>,
/// to the simulated FLASH memory,
/// - Trigger upgrade forces a reboot of the meter including a reload of all applications and regeneration of
/// all registers.
/// </summary>
/// <typeparam name="T"></typeparam>
/// <param name="regName"></param>
/// <param name="value"></param>
/// <remarks date="2024-Dec-10" author="Thomas Wiedebusch">
/// - Initial MockGenesis simulation.
/// </remarks>
private void CheckSpecialActivities<T>(String regName, T value)
{
// Capture "StoreConfiguration" to copy config register contents of App to FLASH
var searchString = "_StoreConfiguration";
if (regName.Contains(searchString))
{
var appName = regName.Replace(searchString, "");
FlashMemory(appName);
}
// Capture "StoreCalibration" to copy config register contents of App to FLASH
searchString = "GENESISFLOW_StoreCalibration";
if (regName.Contains(searchString))
{
// Store single parameter to FLASH
foreach (var registerName in CalibrationResults.CalibrationRegisterNames)
SingleParameterFlashMemory(registerName);
}
// Capture "UpgradePermissions" to copy config register contents of App to FLASH as
// SYSTEM doesn't have a "StoreConfiguration" command
searchString = "SYSTEM_UpgradePermissions";
if (regName.Contains(searchString))
{
SingleParameterFlashMemory(searchString);
}
// Capture "SYSTEM_TriggerUpgrade" to force a reboot and install the actual given firmware
// package description file as FW.
searchString = "SYSTEM_TriggerUpgrade";
if (regName.Equals(searchString) && typeof(T) == typeof(Boolean))
{
var forceTriggerUpgrade = (Boolean)Convert.ChangeType(value, typeof(Boolean));
if (forceTriggerUpgrade)
RebootGenesis();
}
}
/// <summary>
/// Check for special response for predefined registers which reply with a changed parameter like
/// SENSUSRADIO_SystemState set to 0xFF creates a reply of 0x02. This should simulate the real
/// GenesisMeter reply.
/// </summary>
/// <param name="regName"></param>
/// <param name="data"></param>
/// <remarks date="2024-Dec-10" author="Thomas Wiedebusch">
/// - Initial MockGenesis simulation.
/// </remarks>
/// <remarks date="2025-Jul-11" author="Thomas Wiedebusch">
/// - Simulation of reset bits.
/// </remarks>
private void CheckAndModifySpecialReplies(String regName, Byte[] data)
{
// Reset a bit mask
if (SpecialRegisterResetBits.Any(n => regName.Contains(n.RegisterIdent)))
{
var readValue = ReadRegister(regName);
if (readValue != null)
{
for (var c = 0; c < data.Length; c++)
{
if (c < readValue.Length)
{
data[c] = (Byte)(readValue[c] & (Byte)~data[c]);
}
else
{
data[c] = 0;
}
}
}
else
{
for (var c = 0; c < data.Length; c++)
{
data[c] = 0x00;
}
}
}
// Input value forces a constant reply if the input matches
if (SpecialRegisterReplies.Any(n => regName.Contains(n.RegisterIdent)))
{
foreach (var special in SpecialRegisterReplies.Where(special =>
regName.Contains(special.RegisterIdent)))
{
var retVal = true;
// Avoid buffer overflow
if (data.Length < special.ReadBackValue.Length)
break;
for (var i = 0; i < special.WriteValue.Length; i++)
{
// Check the required input which forces a change of the response
if (data[i] != special.WriteValue[i])
retVal = false;
}
if (!retVal)
break;
// Exchange the received value with the special reply
for (var i = 0; i < special.ReadBackValue.Length; i++)
{
data[i] = special.ReadBackValue[i];
}
}
}
}
/// <summary>
/// Mock Read Register and return byte array for test purposes stored in the config register dictionary.
/// </summary>
/// <param name="regName"></param>
/// <param name="expectedLength">expected length for response</param>
/// <param name="skipRetryErrorCode">skip retries on this error code return</param>
/// <returns></returns>
/// <remarks date="2024-Dec-02..03" author="Thomas Wiedebusch">
/// - Initial mock implementation.
/// </remarks>
public override Byte[] ReadRegister(String regName, Int32? expectedLength = null,
UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode)
{
try
{
var regDef = ConfigRegister.GetRegisterDefinitionByName(regName);
var hideDataInLog = regDef.RegisterName.Contains("EncryptionKey");
// Avoid reading of NOT readable registers
if (regDef.RegisterDetail.Privilege.Lvl8 != Access.RW &&
regDef.RegisterDetail.Privilege.Lvl8 != Access.RO)
return null;
var result = ConfigRegister.Get(regName);
// Avoid access of not present register
if (result == null)
{
Logger.Error($"Slot:{Slot} - Read register({regDef.GetIdent()}) returns value (null)");
return null;
}
var rawMsg = RegisterConverter.GetRegisterRawText(regDef, result, hideDataInLog);
Logger.Info($"Slot:{Slot} - Read register({regDef.GetIdent()}), record({rawMsg})");
return result;
}
catch (Exception e)
{
Logger.Error($"Slot:{Slot} - {e.Message}");
}
return null;
}
/// <summary>
/// The simulation of the Genesis reboot:
/// - Login to create the actual installed
/// Kill all old applications,
/// this will force a regeneration of a valid application list and config register dictionary!
/// This will include the copy of FLASH register values or defaults to the config meter dictionary.
/// </summary>
/// <returns></returns>
/// <remarks date="2024-Dec-03" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
/// <remarks date="2024-Dec-07" author="Thomas Wiedebusch">
/// - Reboot count used to check for success of reboot.
/// </remarks>
/// <remarks date="2024-Dec-11..12" author="Thomas Wiedebusch">
/// - Prepared to override the Genesis reboot used in <see cref="MeterResetPsu"/>.
/// </remarks>
public override StatusReturn RebootGenesis()
{
// ReLogin to build initial registers if it has not been performed in advance
ReLogin();
const String registerName = "CUSTOMER_RebootCount";
var rebootCountBeforeReboot = RegisterConverter.ByteArrayToValue<UInt32>(ReadRegister(registerName));
// Simulate reboot execution by increasing the reboot count by one
rebootCountBeforeReboot++;
if (WriteRegister(registerName, rebootCountBeforeReboot))
{
SingleParameterFlashMemory(registerName);
}
// Kill all old applications to force a regeneration of a valid application list
// and config register dictionary!
Logout();
FwVersion = "";
InstalledFwVersion = 0;
Region = "";
RadioFrequencyMhz = null;
MeterAppListVersion.Clear();
ConfigRegister.MeterRegisterDic.Clear();
ConfigApplications.Clear();
// Login to build initial registers if it has not been performed in advance
Login();
var rebootCountAfterReboot = RegisterConverter.ByteArrayToValue<UInt32>(ReadRegister(registerName));
return rebootCountAfterReboot == rebootCountBeforeReboot ? StatusReturn.Okay : StatusReturn.Failed;
}
/// <summary>
/// Clear the config registers to simulate an invalid load or invalid configuration.json
/// </summary>
/// <remarks date="2025-Feb-17" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public void KillConfigRegisters()
{
ConfigRegister.MeterRegisterDic.Clear();
}
#endregion ----------------------------- Mock Genesis simulation ----------------------------------------------
}
}