Compare commits

...
Author SHA1 Message Date
Milan Hanajik 00b1ac48c9 Reconfigured for SENTEC 2018-05-30 18:30:03 +02:00
7 changed files with 36 additions and 21 deletions
+2 -2
View File
@@ -18,7 +18,7 @@
<DebugType>full</DebugType>
<Optimize>false</Optimize>
<OutputPath>bin\Debug\</OutputPath>
<DefineConstants>TRACE;DEBUG;MUNICH</DefineConstants>
<DefineConstants>TRACE;DEBUG;SENTEC</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
<AllowUnsafeBlocks>false</AllowUnsafeBlocks>
@@ -28,7 +28,7 @@
<DebugType>pdbonly</DebugType>
<Optimize>true</Optimize>
<OutputPath>bin\Release\</OutputPath>
<DefineConstants>TRACE;MUNICH</DefineConstants>
<DefineConstants>TRACE;SENTEC</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
</PropertyGroup>
+2 -2
View File
@@ -18,7 +18,7 @@
<DebugType>full</DebugType>
<Optimize>false</Optimize>
<OutputPath>bin\Debug\</OutputPath>
<DefineConstants>TRACE;DEBUG;MUNICH</DefineConstants>
<DefineConstants>TRACE;DEBUG;SENTEC</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
<PlatformTarget>x86</PlatformTarget>
@@ -27,7 +27,7 @@
<DebugType>pdbonly</DebugType>
<Optimize>true</Optimize>
<OutputPath>bin\Release\</OutputPath>
<DefineConstants>TRACE;MUNICH</DefineConstants>
<DefineConstants>TRACE;SENTEC</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
</PropertyGroup>
+2 -2
View File
@@ -21,7 +21,7 @@
<DebugType>full</DebugType>
<Optimize>false</Optimize>
<OutputPath>bin\Debug\</OutputPath>
<DefineConstants>TRACE;DEBUG;MUNICH</DefineConstants>
<DefineConstants>TRACE;DEBUG;SENTEC</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
<AllowUnsafeBlocks>false</AllowUnsafeBlocks>
@@ -31,7 +31,7 @@
<DebugType>pdbonly</DebugType>
<Optimize>true</Optimize>
<OutputPath>bin\Release\</OutputPath>
<DefineConstants>TRACE;MUNICH</DefineConstants>
<DefineConstants>TRACE;SENTEC</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
</PropertyGroup>
+1 -1
View File
@@ -54,7 +54,7 @@ namespace TBF
this.horizontalSplitContainer = new System.Windows.Forms.SplitContainer();
this.mainTabControl = new System.Windows.Forms.TabControl();
this.homeTabPage = new System.Windows.Forms.TabPage();
this.ctrlBrdComponent = new ControlComponent3Munich.UserControl1();
this.ctrlBrdComponent = new ControlComponent_Torino2015.UserControl1();
this.processTabPage = new System.Windows.Forms.TabPage();
this.processTabPageCtrl = new TBF.Screens.ProcessTabPageCtrl6();
this.insertTabPage = new System.Windows.Forms.TabPage();
+21 -7
View File
@@ -3,25 +3,31 @@
<Language>en</Language>
<TestBenches>
<DatabaseSettings>
<BenchName>Test Bench</BenchName>
<BenchName>SENTEC</BenchName>
<IsRealBench>true</IsRealBench>
<ProceduresDBSettings>
<DbType>MySql</DbType>
<ConnectionString>SERVER=localhost; DATABASE=testbench; UID=root; PASSWORD=; CHARSET=utf8;</ConnectionString>
<ConnectionString>SERVER=localhost; DATABASE=sentec; UID=root; PASSWORD=; CHARSET=utf8;</ConnectionString>
</ProceduresDBSettings>
<WaterMetersDBSettings>
<DbType>MySql</DbType>
<ConnectionString>SERVER=localhost; DATABASE=testbench-r; UID=root; PASSWORD=; CHARSET=utf8;</ConnectionString>
<ConnectionString>SERVER=localhost; DATABASE=sentec-r; UID=root; PASSWORD=; CHARSET=utf8;</ConnectionString>
</WaterMetersDBSettings>
<UsersDBSettings>
<DbType>MySql</DbType>
<ConnectionString />
</UsersDBSettings>
</DatabaseSettings>
</TestBenches>
<LastBench>Test Bench</LastBench>
<LoginMethod>UserName</LoginMethod>
<LastBench>SENTEC</LastBench>
<BatchNr>1</BatchNr>
<RealDensity>988.2008</RealDensity>
<RealDensity>998.2008</RealDensity>
<AtTemperature>20</AtTemperature>
<RightPaneHorizSplitterDistance>25</RightPaneHorizSplitterDistance>
<MainWndLeft>75</MainWndLeft>
<MainWndTop>5</MainWndTop>
<TopPaneVerticalSplitterDistance>596</TopPaneVerticalSplitterDistance>
<MainWndLeft>76</MainWndLeft>
<MainWndTop>21</MainWndTop>
<MainWndWidth>1250</MainWndWidth>
<MainWndHeight>750</MainWndHeight>
<ManiWndMaximized>false</ManiWndMaximized>
@@ -29,6 +35,10 @@
<ComponentsDlgTop>100</ComponentsDlgTop>
<ComponentsDlgWidth>850</ComponentsDlgWidth>
<ComponentsDlgHeight>500</ComponentsDlgHeight>
<PopupResultsLeft>0</PopupResultsLeft>
<PopupResultsTop>0</PopupResultsTop>
<PopupResultsWidth>0</PopupResultsWidth>
<PopupResultsHeight>0</PopupResultsHeight>
<PathsDlgLeft>0</PathsDlgLeft>
<PathsDlgTop>0</PathsDlgTop>
<PathsDlgWidth>0</PathsDlgWidth>
@@ -53,6 +63,10 @@
<OneProcedureDlgHeight>0</OneProcedureDlgHeight>
<PrintOrderLeft>0</PrintOrderLeft>
<PrintOrderTop>0</PrintOrderTop>
<EnduranceDlgLeft>0</EnduranceDlgLeft>
<EnduranceDlgTop>0</EnduranceDlgTop>
<EnduranceDlgWidth>0</EnduranceDlgWidth>
<EnduranceDlgHeight>0</EnduranceDlgHeight>
<PrintOrderOnlyGoodResult>false</PrintOrderOnlyGoodResult>
<PrintOrderOnlyLastResult>false</PrintOrderOnlyLastResult>
<ResultsConfigMeters>Vertically</ResultsConfigMeters>
+2 -1
View File
@@ -60,10 +60,11 @@
<logger name="NHibernate"> <level value="ERROR" /> </logger>
<logger name="TBF.BenchControl.StateMachine"> <level value="INFO" /> </logger>
<logger name="TBF.BenchControl.State"> <level value="WARN" /> </logger>
<logger name="TBF.BenchControl.Elde.ControlComdWrap"> <level value="WARN" /> </logger>
<logger name="TBF.BenchControl.Elde.ControlComWrap"> <level value="WARN" /> </logger>
<logger name="TBF.BenchControl.Elde.Pump"> <level value="WARN" /> </logger>
<logger name="TBF.BenchControl.Elde.PumpWithFM"> <level value="WARN" /> </logger>
<logger name="TBF.BenchControl.MettlerToledo"> <level value="WARN" /> </logger>
<logger name="TBF.BenchControl.Fomulas"> <level value="FATAL" /> </logger>
<logger name="TBF.BenchControl.Elde.StartMeasurementOp"> <level value="WARN" /> </logger>
<logger name="TBF.BenchControl.Modbus"> <level value="DEBUG" /> </logger>
</log4net>
+6 -6
View File
@@ -39,7 +39,7 @@
<DebugType>full</DebugType>
<Optimize>false</Optimize>
<OutputPath>bin\Debug\</OutputPath>
<DefineConstants>TRACE;DEBUG;MUNICH;CAMERA</DefineConstants>
<DefineConstants>TRACE;DEBUG;SENTEC;STABLE_MASS_EXTRAS</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
<AllowUnsafeBlocks>true</AllowUnsafeBlocks>
@@ -49,7 +49,7 @@
<DebugType>pdbonly</DebugType>
<Optimize>true</Optimize>
<OutputPath>bin\Release\</OutputPath>
<DefineConstants>TRACE;MUNICH;CAMERA</DefineConstants>
<DefineConstants>TRACE;SENTEC;STABLE_MASS_EXTRAS</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
<PlatformTarget>x86</PlatformTarget>
@@ -58,7 +58,7 @@
<PropertyGroup Condition="'$(Configuration)|$(Platform)' == 'Debug|x86'">
<DebugSymbols>true</DebugSymbols>
<OutputPath>bin\Debug\</OutputPath>
<DefineConstants>TRACE;DEBUG;MUNICH;CAMERA</DefineConstants>
<DefineConstants>TRACE;DEBUG;SENTEC;STABLE_MASS_EXTRAS</DefineConstants>
<DebugType>full</DebugType>
<PlatformTarget>x86</PlatformTarget>
<ErrorReport>prompt</ErrorReport>
@@ -67,7 +67,7 @@
</PropertyGroup>
<PropertyGroup Condition="'$(Configuration)|$(Platform)' == 'Release|x86'">
<OutputPath>bin\x86\Release\</OutputPath>
<DefineConstants>TRACE;MUNICH;CAMERA</DefineConstants>
<DefineConstants>TRACE;SENTEC;STABLE_MASS_EXTRAS</DefineConstants>
<Optimize>true</Optimize>
<DebugType>pdbonly</DebugType>
<PlatformTarget>x86</PlatformTarget>
@@ -97,8 +97,8 @@
<SignManifests>false</SignManifests>
</PropertyGroup>
<ItemGroup>
<Reference Include="ControlComponent3Munich">
<HintPath>..\packages\ControlBoard\Munich\ControlComponent3Munich.dll</HintPath>
<Reference Include="ControlComponent3U">
<HintPath>..\packages\ControlBoard\Sentec\ControlComponent3U.dll</HintPath>
</Reference>
<Reference Include="FluentNHibernate">