Milan Hanajik
|
f04cdccd20
|
EtPulsesK (FlyingStartMassCollectionProlonged) fixed for IPERL_TURA and IPERL_SPECIAL, ver. 2.18.1052
|
2018-11-08 10:41:05 +01:00 |
|
Milan Hanajik
|
82acf60f2e
|
Target flow range for flow control shrinked by 15% from each side, ver. 2.18.2051
|
2018-11-08 09:54:40 +01:00 |
|
Milan Hanajik
|
68413867ad
|
FlyingStartMassCollectionProlonged fixed for iPerlSpecial, ver. 2.18.1050
|
2018-11-07 16:28:36 +01:00 |
|
Milan Hanajik
|
1fd8881d53
|
LastError added to MeterTestRslt, result items, etc. when ORACLE_DB defined, etc. (CalibFactorLNA, OrigCalibFactorLNA)
|
2018-11-07 08:43:36 +01:00 |
|
Milan Hanajik
|
cebdd71065
|
MID pulses for each meter calculated correctly in all FlyingStart... methods for datastream meters.
|
2018-11-07 08:13:48 +01:00 |
|
Milan Hanajik
|
668304cb72
|
Bug fix in Statistics : Min, Max calculation and UpdateGraph( ), ver. 2.18.1049
|
2018-11-06 13:39:49 +01:00 |
|
Milan Hanajik
|
c28c5a5554
|
Bug fix in Various.TankWithLevelMsrmnt.Tank.
|
2018-11-02 10:17:52 +01:00 |
|
Milan Hanajik
|
450493069c
|
(1) SequenceBase.DrainTheTank( ) : DrainValve2 is open first, DrainValve in the 2nd half, (2) Two phase draining in MainSeq when bench is started, ver. 2.18.1047
|
2018-10-26 11:21:07 +02:00 |
|
Milan Hanajik
|
d7519aa95a
|
Draining with 2 drain valves in SequenceBase.
|
2018-10-25 19:44:54 +02:00 |
|
Milan Hanajik
|
e89ab89874
|
TankCfgCtrl displays ILevelMeter-s, DrainValve2 is in IScaleOrTank and TankWithLevelMsrmnt UI, ver. 2.18.1046
|
2018-10-25 18:09:08 +02:00 |
|
Milan Hanajik
|
025fa81941
|
SequencBase : ReadRegistersTempPressAmbient( ) fixed - works OK without an IScale - start/stop method works with a tank, ver.2.18.1045
|
2018-10-25 17:02:12 +02:00 |
|
Milan Hanajik
|
845c66b511
|
HART communication : IHart,Hart, Nivotrack changes, sending/receiving works OK. Todo: Interface the level, ver. 2.18.1044
|
2018-10-25 15:34:48 +02:00 |
|
Milan Hanajik
|
3725e238fc
|
Various.TankWithLevelMsrmnt can use a calibration table loaded from a CSV file.
|
2018-10-25 15:34:46 +02:00 |
|
Milan Hanajik
|
ac2ac82187
|
Diverter fixed for CEVAK_200, ver. 2.18.1042
|
2018-10-24 17:16:56 +02:00 |
|
Milan Hanajik
|
5e6be0c4b4
|
(1) Bug fix in calculations in flying start methods when WMPulses == 1, (2) VolumeCTV results item added, ver. 2.18.1041
|
2018-10-24 15:04:51 +02:00 |
|
Milan Hanajik
|
ed66c6a259
|
(1) Tank & ManualLevelMsrmnt components added, (2) Sequences cope with IScaleOrTank, (3) FixedStartTankCollection & FlyingStartTankCollection added, etc., ver. 2.18.1040
|
2018-10-24 13:18:38 +02:00 |
|
Milan Hanajik
|
0db7736247
|
Minor fix in TestMethods.FlyingStart.FlyingStartSeq.
|
2018-10-23 19:45:53 +02:00 |
|
Milan Hanajik
|
02cebe0966
|
CEVAK 200 Elde component upgraded: 23.10.2018, I4 and I5 fixed.
|
2018-10-23 13:13:26 +02:00 |
|
Milan Hanajik
|
4f2bb6291f
|
Strings, ver. 2.18.1036
|
2018-10-21 10:58:38 +02:00 |
|
Milan Hanajik
|
498c8afbe4
|
ver. 2.18.1035
|
2018-10-18 12:57:09 +02:00 |
|
Milan Hanajik
|
0e6dce4750
|
Error limits before Q2 correction are not shifted to target, factor 1.0 used for Q2CorrType.RL and Q2CorrType.LR, ver. 2.18.1034
|
2018-10-18 09:28:35 +02:00 |
|
Milan Hanajik
|
7a74579c8b
|
Q2 correction RL and LR addresses swapped, Q2 correction value multiplied by 0.5, ver. 2.18.1033
|
2018-10-17 14:41:07 +02:00 |
|
Milan Hanajik
|
c23630a980
|
Separate addresses Q2CorrFactorsAddrRL (0x1878) and Q2CorrFactorsAddrLR (0x1879), ver. 2.18.1031
|
2018-10-17 11:31:28 +02:00 |
|
Milan Hanajik
|
205df83c1c
|
Test sequences modified, Q2CorrRFlow and Q2CorrLFlow set in iPerlCommunicationForm only, ver. 2.18.1030
|
2018-10-17 09:56:01 +02:00 |
|
Milan Hanajik
|
b26f65dab4
|
(1) Diverter : Fixed 'flowMtrNr4Cmd' for FUZHOU_100, (2) SendCalibData(..., MeretModbus=0xff), ver. 2.18.1029
|
2018-10-16 10:22:04 +02:00 |
|
Milan Hanajik
|
8d1ac8f41d
|
(1) 'Max_test_index' added to Results, (2) "Max.test index" added to BenchInfoEx, (3) ResultsTabPageCtrl draws NOK wm-s with max. test index in 'Orange', (4) bug fix in ProductionTracing simulation, ver. 2.18.1027
|
2018-10-15 14:42:17 +02:00 |
|
Milan Hanajik
|
115916fd36
|
ver. 2.18.1026
|
2018-10-15 13:20:36 +02:00 |
|
Milan Hanajik
|
6641ed9d96
|
Bug fix in iPerlHead.CalibTarget property, ver. 2.18.1025
|
2018-10-15 13:09:30 +02:00 |
|
Milan Hanajik
|
5e3d408706
|
IsRemoteDBCompatible( ) copes with no remote DB connection, ver. 2.18.1024
|
2018-10-14 21:58:40 +02:00 |
|
Milan Hanajik
|
8fc9e3e5ce
|
On screen results arrangement : MinWidth, MinHeight.
|
2018-10-13 06:24:20 +02:00 |
|
Milan Hanajik
|
e7aa9731d0
|
(1) DataEntry.Std6,12,24,48: Excl. mark behaviour, (2) Kepno component upgraded (12.10.2018), (3) TestMet.PulsesTest: OK btn removed, ver. 2.18.1023
|
2018-10-12 16:04:06 +02:00 |
|
Milan Hanajik
|
0fc63655e9
|
iPerlHead modification : 'nominalTestFlowLph' calculated from q2adjTestData, test method sequences simplified, ver. 2.18.1021
|
2018-10-12 13:25:21 +02:00 |
|
Milan Hanajik
|
86b47cb434
|
ProcedureDlg : History TAB in progress.
|
2018-10-11 13:53:24 +02:00 |
|
Milan Hanajik
|
b3ec97d95c
|
TestMethods.SensitivityTest : Clean-up, in progress.
|
2018-10-11 11:06:51 +02:00 |
|
Milan Hanajik
|
1620758545
|
E1 error indicator modified, average flow calculated from CTV volume and test time verified, ver. 2.18.1019
|
2018-10-11 10:58:08 +02:00 |
|
Milan Hanajik
|
5a2d51db95
|
Statistics.Start( ) has argument 'skippedsamplesCount', constructor sets 'DefaultSkippedSamplesCount', all FixedStart methods use Math.Max(5, (int)(TstTime/10)), other methods 0, ver. 2.18.1018
|
2018-10-11 10:26:02 +02:00 |
|
Milan Hanajik
|
c0e99364a4
|
Result, Test passed and Test done items can be formatted, PassedColorStr( ) has argument 'yesNoFormatOrEmpty', ver. 2.18.1017
|
2018-10-10 11:13:08 +02:00 |
|
Milan Hanajik
|
371a27c646
|
Output.FileWriters.IperlLogger.Write bug fix : Qfrom, Qto etc. were missing, ver. 2.18.1016
|
2018-10-10 08:59:35 +02:00 |
|
Milan Hanajik
|
4a06dcff3e
|
(1) TestMethods.PulsesTest : modeless form closed at the end of test, (2) TestMethods.PulsesTestManual : fixes in form items visibility, ver. 2.18.1015
|
2018-10-09 13:54:36 +02:00 |
|
Milan Hanajik
|
0f54bf86ac
|
ver. 2.18.1014
|
2018-10-08 11:39:12 +02:00 |
|
Milan Hanajik
|
921c524f0e
|
Output.FileWriters.IperlLogger.Writer : Bug fixed, data of wm0 were logged for all water meters in the batch, ver. 2.18.1013
|
2018-10-08 11:00:18 +02:00 |
|
Milan Hanajik
|
a8df9b50de
|
(1) SLM_END Elde comp. updated (03.10.2018), (2) Elde.TempMeterMeret component added, (3) MeretRS485Address array size increased for 2 new Meret temp.meters for SLM_END, ver. 2.18.1012
|
2018-10-05 11:34:34 +02:00 |
|
Milan Hanajik
|
5da9b1e94e
|
Fixed a bug when adding a list of new components using a script file, ver. 2.18.1010
|
2018-10-03 14:56:42 +02:00 |
|
Milan Hanajik
|
63871c9bcc
|
Changes for IZRAEL_50, DEWA_50 removed (replaced by FEWA_50)
|
2018-10-03 14:56:30 +02:00 |
|
Milan Hanajik
|
e5b61825ff
|
Ultrasound level meter modbus communication completed.
|
2018-10-01 16:40:42 +02:00 |
|
Milan Hanajik
|
2d484ea993
|
TBF.BenchControl.Configs.ParamsProvider.ComponentCfgCtrl displays a message box when a parameter is invalid, ver. 2.18.1010
|
2018-10-01 11:18:35 +02:00 |
|
Milan Hanajik
|
b5b7d50742
|
TestiInfo for Greece added (Q1Q2Q2adjQ3), minor fix in SensusOracle.Database, ver. 2.18.1009
|
2018-10-01 09:01:36 +02:00 |
|
Milan Hanajik
|
19d77a9ad9
|
SENTEC : FlyingStartMassCollectionSeq : Tank draining is completed before the flow control starts (as in Berlin).
|
2018-09-28 14:16:12 +02:00 |
|
Milan Hanajik
|
e77c0460de
|
UltrasoundLevelMeter parent name is 'Modbus' only.
|
2018-09-27 15:20:34 +02:00 |
|
Milan Hanajik
|
2ad5843f4f
|
Cleanup: bool Output.SensusTestInfo.AreCompatible(.,. ) introduced, etc, ver. 2.18.1008
|
2018-09-27 15:02:36 +02:00 |
|