Commit Graph

34 Commits

Author SHA1 Message Date
Milan Hanajik
70f38e9352 Adjustment test method/adjustment form supports 10-12 water metes, version 1.5.129. 2015-10-05 09:59:27 +02:00
Milan Hanajik
43eaa61007 Adjustment test method for 24 WMs fixed, MakeSimulated(..) and MakeSimulatedCompound(..) moved to SequenceBase, version 1.5.127. 2015-10-04 22:41:52 +02:00
Milan Hanajik
72754ebe10 Flow control during a test, version 1.5.121. 2015-09-22 18:39:00 +02:00
Milan Hanajik
d7e6a69ca9 StartMeasurementOp interface changed: OutputPath is the first argment 2015-09-22 17:03:26 +02:00
Milan Hanajik
4a35215be9 Adjustment for 24 water meters, fixed a bug in trransition sequence editor, version 1.5.115. 2015-09-17 20:58:56 +02:00
Milan Hanajik
d041cd1d20 Evaluate and Publish properties of test methods changed to stateless functions Evaluate(test) and Publish(test), this fixes results, version 1.5.107 2015-09-06 22:21:54 +02:00
Milan Hanajik
33963ec8cf Version 1.5.84. Reading registers, scales, temperature, pressure, ... during test done in one state in the sequence.
Many changes in TestMethods.iPerlCommunication and WaterMeters.iPerl.WaterMeter. iPerl measurement with opto-data works OK.
Logging in State changed, ...
2015-08-19 13:04:47 +02:00
Milan Hanajik
f85fbd0b55 Problems when passing flowmeter/diverter info to test start by SendCommand() fixed, version 1.5.77. 2015-08-14 18:14:08 +02:00
Milan Hanajik
58f872c6f4 Bug fix in adjustment dialog for 24 watermeters, version 1.5.64. 2015-07-03 02:42:30 +02:00
Milan Hanajik
5292088622 A new form for 24 water meters in adjustment dialog 2015-07-02 17:28:11 +02:00
Milan Hanajik
7b902e8ca3 IComponentFactory.DummyComponent() interface function added and implemented in all components. 2015-06-29 11:14:33 +02:00
Milan Hanajik
0cea24246c Error message due to incorrect configuration is cleared after selecting another procedure/test.
Return value from WaitBeginFormClosed(..) changed from bool to enum UIFlowControl.
2015-06-25 04:48:28 +02:00
Milan Hanajik
edb6d5e8b6 'EndCondiiton' and 'Communication' added to TransitionStep (transition sequence). TODO: EndConditions functionality, version 1.5.44 2015-05-22 11:21:56 +02:00
Milan Hanajik
cd9042a648 PulsesPerLiter added to Entities.MeterTestResult and to result items. Version 1.4.36
More times added to Entities.Test (TimeBeforeFlow, TimeFlow2Mass, TimeMass2Start, TimeStop2Mass).
Activity display fixed in FlyingStartCollectionMethod.
2015-05-19 15:38:58 +02:00
Milan Hanajik
39eb2cfd57 Entry form related improvements / bugfixes (Fixed start collection method related). 2015-04-28 15:27:47 +02:00
Milan Hanajik
be78bb5ce0 Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
Milan Hanajik
1e63ded8e1 MetersKind.Standard in TBF/Entities/Enums.cs reverted to MetersKind.Single 2015-03-25 05:35:05 +01:00
Milan Hanajik
23d5e6d19d Disabled watermeters will not appear in results (screen, ResultsPrinters.Basic and ResultsWriters.Basic).
Updating Disabled (default = false) is provided by DataEntry.Standard when entering serial numbers.
2015-03-25 03:57:46 +01:00
Milan Hanajik
7dce565e4f MetersKind.Single in TBF/Entities/Enuns.cs renamed to MetersKind.Standard 2015-03-25 02:31:28 +01:00
Milan Hanajik
f524186b70 More DataEntry.Standard related changes 2015-03-25 02:14:42 +01:00
Milan Hanajik
dc9577eaa0 Test methods for standard watermeter use IWatermeter.Disabled flag to remove non-existing meter results 2015-03-24 10:11:20 +01:00
Milan Hanajik
c005a5cb26 Solves issue with an opened CycleBeginForm after abort and re-selection in Israel:
- CloseCycleBeginForm() -> WaitBeginFormClosed()
- CloseBeginForm() added to SequenceBase(forced dialog close)
- CloseModellFormHandler added to UiBridge.Bridge
2015-03-01 11:13:26 +01:00
Milan Hanajik
0c9408ff64 More configuration checks when starting a test 2015-02-02 23:18:28 +01:00
Milan Hanajik
9bd5fba6dc (1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik
e1756f692c Confirmed results to SummaryResults.txt logger 2015-02-02 11:38:42 +01:00
Milan Hanajik
56a9a7cf1b Test results are written into database after confirming with END 2015-02-02 00:08:47 +01:00
Milan Hanajik
ce6214f631 Zapne pumpu pred vypustanim aj pri ostatnych metodach 2015-02-01 19:30:00 +01:00
Milan Hanajik
57a7510d05 Center stripe in the Error dialog of the Adjustment method 2015-02-01 19:28:26 +01:00
Milan Hanajik
806f4efe6a Results printing and saving uses Publish property of GenericDevices.ITestMethod 2015-02-01 16:20:27 +01:00
Milan Hanajik
efa14c6ebb Adjustment results will not be printed, shown, etc. 2015-02-01 08:20:13 +01:00
Milan Hanajik
0c4da37e85 Adjustment: Graphics added, to be tested 2015-01-28 22:14:30 +01:00
Milan Hanajik
5653628bf7 Adjust: Larger font, place for graphics 2015-01-28 20:57:03 +01:00
Milan Hanajik
94accbf58b Bugfix: Adjustment method modeless dialog was not started in UI thread, freezes 2015-01-28 19:33:02 +01:00
Milan Hanajik
508f47cb6b Adjustment test method ready for tests 2015-01-28 18:18:46 +01:00