Error message due to incorrect configuration is cleared after selecting another procedure/test.
Return value from WaitBeginFormClosed(..) changed from bool to enum UIFlowControl.
This commit is contained in:
@@ -57,6 +57,12 @@ namespace TBF.BenchControl
|
||||
FC, /// FC protocol with Siemens address (1..31), default serial settings are 9600Bd, 8bits, PE, 1stop
|
||||
}
|
||||
|
||||
public enum UIFlowControl
|
||||
{
|
||||
Continue,
|
||||
Stop,
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// StateMachine events (issued by operations, IOperation derived classes)
|
||||
/// </summary>
|
||||
|
||||
@@ -244,7 +244,9 @@ namespace TBF.BenchControl.Sequences
|
||||
|
||||
cycle_or_test_selected:
|
||||
|
||||
if (WaitBeginFormClosed()) goto stop_within_cycle; /// Make sure the entry form is closed
|
||||
UiBridge.Bridge.OnError(this, string.Empty); /// Clear an error message (if any)
|
||||
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stop_within_cycle; /// Make sure the entry form is closed
|
||||
|
||||
Bridge.Bench2UI(ButtonsEtc.StopBtnEn); /// Hide buttons
|
||||
|
||||
@@ -371,11 +373,12 @@ namespace TBF.BenchControl.Sequences
|
||||
purge_end:
|
||||
save_results:
|
||||
|
||||
Bridge.Bench2UI(ButtonsEtc.StopBtnEn); // Hide the most of buttons
|
||||
UiBridge.Bridge.OnError(this, string.Empty); /// Clear an error message (if any)
|
||||
Bridge.Bench2UI(ButtonsEtc.StopBtnEn); /// Hide the most of buttons
|
||||
|
||||
if (State.LastEvents.Contains(Event.ModelessFormIsOpen))
|
||||
{
|
||||
if (WaitBeginFormClosed()) goto stop;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stop;
|
||||
}
|
||||
else if (State.LastEvents.Contains(Event.ModelessFormClosed))
|
||||
{
|
||||
|
||||
@@ -633,12 +633,12 @@ namespace TBF.BenchControl.Sequences
|
||||
/// This function is typically called at the end of the first test of the procedure.
|
||||
/// </summary>
|
||||
/// <returns>false = OK, true = stop pressed</returns>
|
||||
protected bool WaitBeginFormClosed()
|
||||
protected UIFlowControl WaitBeginFormClosed()
|
||||
{
|
||||
GenericDevices.IDataEntry dataEntryCmpnt =
|
||||
TbfComponents.FindComponent(StateMachine.Procedure.DataEntry) as GenericDevices.IDataEntry;
|
||||
|
||||
bool forcedClose = false; /// When STOP button pressed
|
||||
bool stopPressed = false; /// true when STOP button pressed
|
||||
|
||||
if (dataEntryCmpnt is IHasCycleBeginForm)
|
||||
{
|
||||
@@ -657,7 +657,7 @@ namespace TBF.BenchControl.Sequences
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
if (e.Contains(Event.UiCmdStop))
|
||||
{
|
||||
forcedClose = true;
|
||||
stopPressed = true;
|
||||
break;
|
||||
}
|
||||
}
|
||||
@@ -674,10 +674,10 @@ namespace TBF.BenchControl.Sequences
|
||||
.EnterState();
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
|
||||
if (e.Contains(Event.UiCmdStop)) { forcedClose = true; }
|
||||
if (e.Contains(Event.UiCmdStop)) { stopPressed = true; }
|
||||
}
|
||||
|
||||
return forcedClose;
|
||||
return stopPressed ? UIFlowControl.Stop : UIFlowControl.Continue;
|
||||
}
|
||||
|
||||
|
||||
|
||||
@@ -240,7 +240,7 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
||||
//------------------------------------------------
|
||||
|
||||
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
||||
if (WaitBeginFormClosed()) goto stopTest;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
||||
|
||||
///
|
||||
/// Populate TestResult data entity with data
|
||||
|
||||
@@ -362,7 +362,7 @@ namespace TBF.BenchControl.TestMethods.CombinedMeters
|
||||
//------------------------------------------------
|
||||
|
||||
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
||||
if (WaitBeginFormClosed()) goto stopTest;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
||||
|
||||
/// Optionally supress pulses from the large water meter
|
||||
if (testParams.SupressTrills)
|
||||
|
||||
+1
-1
@@ -541,7 +541,7 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
||||
|
||||
|
||||
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
||||
if (WaitBeginFormClosed()) goto stopTest;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
||||
|
||||
/// Optionally supress pulses from the large water meter
|
||||
if (testParams.SupressTrills)
|
||||
|
||||
+1
-1
@@ -504,7 +504,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartCombinedMeters
|
||||
//------------------------------------------------
|
||||
|
||||
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
||||
if (WaitBeginFormClosed()) goto stopTest;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
||||
|
||||
///
|
||||
/// Populate TestResult data entity with data
|
||||
|
||||
+1
-1
@@ -493,7 +493,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
||||
//------------------------------------------------
|
||||
|
||||
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
||||
if (WaitBeginFormClosed()) goto stopTest;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
||||
|
||||
///
|
||||
/// Populate TestResult data entity with data
|
||||
|
||||
@@ -209,7 +209,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
||||
//------------------------------------------------
|
||||
|
||||
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
||||
if (WaitBeginFormClosed()) goto stopTest;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
||||
|
||||
///
|
||||
/// Populate TestResult data entity with data
|
||||
|
||||
+1
-1
@@ -376,7 +376,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartCollectionMethod
|
||||
//------------------------------------------------
|
||||
|
||||
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
||||
if (WaitBeginFormClosed()) goto stopTest;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
||||
|
||||
///
|
||||
/// Populate TestResult data entity with data
|
||||
|
||||
@@ -253,7 +253,7 @@ namespace TBF.BenchControl.TestMethods.LeakTest
|
||||
//------------------------------------------------
|
||||
|
||||
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
||||
if (WaitBeginFormClosed()) goto stopTest;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
||||
|
||||
///
|
||||
/// Populate TestResult data entity with data
|
||||
|
||||
@@ -172,7 +172,7 @@ namespace TBF.BenchControl.TestMethods.PMaxTest
|
||||
//------------------------------------------------
|
||||
|
||||
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
||||
if (WaitBeginFormClosed()) goto stopTest;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
||||
|
||||
///
|
||||
/// Populate TestResult data entity with data
|
||||
|
||||
+1
-1
@@ -326,7 +326,7 @@ namespace TBF.BenchControl.TestMethods.ReferenceFlowmeterCalibration
|
||||
//------------------------------------------------
|
||||
|
||||
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
||||
if (WaitBeginFormClosed()) goto stopTest;
|
||||
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
||||
|
||||
///
|
||||
/// Populate TestResult data entity with data
|
||||
|
||||
Reference in New Issue
Block a user