Milan Hanajik
|
c187dc9abf
|
- FlyingStart with corrections
- FlowMeterCouple -> FlowMeterTwins
|
2014-09-15 22:00:37 +02:00 |
|
Milan Hanajik
|
a919a3e9d6
|
- FLyngStart sequence (without balances) tested -> OK, Todo: use
corrections
- totalPulses calculated correctly in case of I11+I12 (use of two flowmeters)
|
2014-09-12 07:18:24 +02:00 |
|
Milan Hanajik
|
3559ab0ab3
|
- Elde.FlowMeterCouple component added
- LtrPerPulse and LtrPerPulseCorrected property/function added to IFlowMeter and flowmeters
|
2014-09-10 13:43:33 +02:00 |
|
Milan Hanajik
|
fcfdfeca41
|
- COmponent properties 'Position' --> 'Idx0' or 'Idx1'
- process data logging, RegulVal position logging
- changes for I11+I12, NOK yet
|
2014-09-10 12:05:49 +02:00 |
|
Milan Hanajik
|
c3050863a6
|
- Component update (temp., etc.)
- Process data logging update (SequenceBase.cs)
|
2014-09-09 18:29:01 +02:00 |
|
Milan Hanajik
|
d0ebb62ab3
|
- Component update (temp.)
- Process data logging, first trial
|
2014-09-09 16:18:23 +02:00 |
|
Milan Hanajik
|
354c13853f
|
All PumpsWithFM are controlled when opening pumps at the test start
|
2014-09-09 09:14:47 +02:00 |
|
Milan Hanajik
|
d14cb175a6
|
FlowStableSec parameter added to RegulValve
|
2014-09-08 20:24:46 +02:00 |
|
Milan Hanajik
|
cc2a24cee5
|
- Fixed a bug in tank emptying
- Component
|
2014-09-08 17:13:51 +02:00 |
|
Milan Hanajik
|
c0d81297f5
|
Balance empty mass is configurable
|
2014-09-08 15:39:33 +02:00 |
|
Milan Hanajik
|
6eee83042b
|
PmpWithFM and Transition sequences functionality implemented
|
2014-09-08 13:16:31 +02:00 |
|
Milan Hanajik
|
d98762aaf8
|
Transition sequences with PumpsFM[%] are OK in UI and in DB, not yet in the control code
|
2014-09-07 17:01:30 +02:00 |
|
Milan Hanajik
|
99377ce3b9
|
Size and location of some dialogs saved: Components, Paths, Transitions, Metrology, Procedures, Procedure
|
2014-09-07 09:34:28 +02:00 |
|
Milan Hanajik
|
f9d2c43d57
|
- Tank empty threshold changed (increased)
- Fixed a bug in SequenceBase.LtrPerRefPulse[] initialization
|
2014-09-06 18:30:13 +02:00 |
|
Milan Hanajik
|
b8faca784e
|
- ReferenceFlowmeterCalibration method and sequence (ready for tests)
- FlyingStart method and sequence files prepared for implementation (copies of FlyingStartMassCollection)
|
2014-09-06 17:34:26 +02:00 |
|
Milan Hanajik
|
36f2842b01
|
- Fixed a bug in valves inversion
- Changes in ProcessTabPageCtrl
|
2014-09-06 13:32:38 +02:00 |
|
Milan Hanajik
|
a6f5b287c9
|
Fixed a bug in emptying valves initialization on StateMachine startup
|
2014-09-06 11:35:10 +02:00 |
|
Milan Hanajik
|
ef8284586e
|
SetValves operation uses Delay of 'Valve', 'Pump' and 'PumpWithFM'
|
2014-09-06 09:07:45 +02:00 |
|
Milan Hanajik
|
87f42ba291
|
Delay added to IValve and Pumps, no delay functionality yet
|
2014-09-06 08:10:08 +02:00 |
|
Milan Hanajik
|
6933442e76
|
- possibility to invert valves (UI as well as the functionality)
- UI prepared for the usage of valve delays
|
2014-09-06 07:37:27 +02:00 |
|
Milan Hanajik
|
74a6800f9e
|
Changes done on Fuzhou300 system:
- ControlComDev.SetFMFreq() modifications (array size)
- StatusP and Route logging
- StatusP bit assignments: bit3 -> bit5
- MettlerToledo logging
|
2014-09-05 22:14:12 +02:00 |
|
Milan Hanajik
|
1d098f7893
|
- Modifications for 'StableTime' (ValveMove, RegulValve, etc.
- SHA1 checksum calculated and displayed in AboutDlg (sample data 'nejaky text')
- Modifications for the Fuzhou300 component
|
2014-09-05 14:17:12 +02:00 |
|
Milan Hanajik
|
f01a0d84fe
|
Folder with files for FixedStartMassCollection (copy of FlyingStart..) added to project, builds OK
|
2014-09-05 09:06:23 +02:00 |
|
Milan Hanajik
|
8ff05bcccf
|
- StartValve added to OutputPath
- bug fixed in MeterTestResultMap: 'EndState' was not mapped into the database
|
2014-09-03 16:55:09 +02:00 |
|
Milan Hanajik
|
229564750f
|
FLow meter position may be 0 (sum of two), flow meter range up to 1600 m3/h
|
2014-09-03 15:34:44 +02:00 |
|
Milan Hanajik
|
08468e60d6
|
- reconfigured to use Munich component and 5 watermeters
- valve categories used in paths, Category property added to IValve
|
2014-09-02 18:10:16 +02:00 |
|
Milan Hanajik
|
c767512fad
|
- Camera ROI DebugLevel inheritance fixed/improved, parent can be Off
- avoid empty lines in logs after SendCommand, SendCalibData, ValveMove logs
|
2014-08-15 20:50:42 +02:00 |
|
Milan Hanajik
|
ea59dd0932
|
FlyingStart...Seq and CombinedMetersSeq sequences cleaned-up:
- Stop should work OK
- Target flow is tested and config error is shown in case it's NOK
- TestEnd sequence executed on Error
|
2014-08-15 14:32:03 +02:00 |
|
Milan Hanajik
|
596667a67e
|
Default action and stopping the FM-controlled pump
moved to SequenceBase.Transition(sequence, context).
Sequences cleaned-up.
|
2014-08-14 09:06:01 +02:00 |
|
Milan Hanajik
|
e128784bb8
|
Sequences cleaned-up
|
2014-08-13 16:20:00 +02:00 |
|
Milan Hanajik
|
c56848958e
|
- MessageBoxOp, MesssageBoxForm
- Configuration error handling in MainSeq
- Paths selection inside MainSeq
|
2014-08-12 22:21:26 +02:00 |
|
Milan Hanajik
|
f4e7c7e88d
|
Dnes koncim
|
2014-08-12 18:22:32 +02:00 |
|
Milan Hanajik
|
38a88e841b
|
- Three tanks, balances, empty valves supported
- Code cleanup
|
2014-08-12 14:52:42 +02:00 |
|
Milan Hanajik
|
d177a4f892
|
- Fixed bugs in (simultaneous) tank emptying
|
2014-08-11 21:19:47 +02:00 |
|
Milan Hanajik
|
7cdfad0738
|
- Bug fix in State.cs
- Component for DN100 being used
|
2014-08-11 18:33:30 +02:00 |
|
Milan Hanajik
|
ffb4d5afb6
|
Koncim 8.8.14
|
2014-08-08 16:25:51 +02:00 |
|
Milan Hanajik
|
ae09afef59
|
More changes - Modeless form for S/N entry ...
|
2014-08-08 15:22:24 +02:00 |
|
Milan Hanajik
|
5302aee2a1
|
Modeless form for S/N entry does not prevent test from starting
|
2014-08-08 12:45:15 +02:00 |
|
Milan Hanajik
|
ea31fc31fe
|
Fixed but in main sequence when there are no scales
|
2014-08-08 09:37:45 +02:00 |
|
Milan Hanajik
|
a597da1e18
|
Waits 15sec after setting the initial flow before detection starts
|
2014-08-01 10:54:38 +02:00 |
|
Milan Hanajik
|
fd2db3e229
|
As sent to Munich
|
2014-08-01 08:36:17 +02:00 |
|
Milan Hanajik
|
836daaa5a1
|
- German translations
- IBox, FloatBox, IntBox related changes
|
2014-07-31 22:17:48 +02:00 |
|
Milan Hanajik
|
66feec63de
|
Koncim: IBox, etc.
|
2014-07-31 17:04:09 +02:00 |
|
Milan Hanajik
|
9a9a09f16d
|
TolerRed parameter premenovany a pouzity ako Filter
|
2014-07-31 00:50:42 +02:00 |
|
Milan Hanajik
|
26b2c1f1a9
|
Simultaneous Tank-Empty op-s possible
|
2014-07-31 00:03:19 +02:00 |
|
Milan Hanajik
|
4bcffdc3a9
|
- Fixed bugs in DataEntry-Munich3 forms
- Troubleshooting camera detection
|
2014-07-29 19:25:13 +02:00 |
|
Milan Hanajik
|
8c83965315
|
ProcedureName added to TestResults entity, Basic writer changes
|
2014-07-29 15:06:29 +02:00 |
|
Milan Hanajik
|
019e85066f
|
- Data from entry forms copied to test results as well
- Printed results layout change (subtitles in bold)
|
2014-07-29 08:42:19 +02:00 |
|
Milan Hanajik
|
7261d44728
|
Emergency stop form reactivated
|
2014-07-29 00:39:43 +02:00 |
|
Milan Hanajik
|
805e66d537
|
EndState added to MeterTestResult, UpdateTestResults added to EntryForms and IDataEntry
|
2014-07-28 23:12:43 +02:00 |
|