Commit Graph

29 Commits

Author SHA1 Message Date
Milan Hanajik
d3532a2796 PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
bb31cdae56 Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results 2015-01-15 06:34:36 +01:00
Milan Hanajik
9c1db2778e Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page 2015-01-15 03:16:14 +01:00
Milan Hanajik
34dc592e59 Timeout while setting the water flow handled correctly: message displayed, test aborted 2015-01-12 05:56:19 +01:00
Milan Hanajik
de90a4638a Prepared: PID coefficient of the output path is ready to be used,
and not the regul.valve parameter. See  // TODO PID: ...  in source code.
 Database: 'PidCoef' float should be added to 'OutputPath' after col.'FlowMeter'
2015-01-03 21:17:11 +01:00
Milan Hanajik
1afd6870c3 Time2MassMsrmt implemented, database tables Test and TestResult changed 2014-12-11 08:49:07 +01:00
Milan Hanajik
930db8c379 - many process tab page improvements
- program start and state changes logging improved
- IDC100 measurement related changes: reference pulses in RegisterReader
- etc
2014-10-02 20:56:24 +02:00
Milan Hanajik
b6bbad66e7 IDC Camera related fixes - to be tested 2014-10-02 18:05:54 +02:00
Milan Hanajik
1c34946a6b Bugs in sequences fixed: Missing CheckUiOp 2014-09-26 17:48:55 +02:00
Milan Hanajik
9868c41640 Zmeny urobene v ST pri testovani kamery 2014-09-24 19:58:05 +02:00
Milan Hanajik
a79be1e07a - bug fixed when component (class) in the DB does not exist in the code
- preparing FixedStartMassCollection sequence
2014-09-16 12:04:08 +02:00
Milan Hanajik
a919a3e9d6 - FLyngStart sequence (without balances) tested -> OK, Todo: use
corrections
- totalPulses calculated correctly in case of I11+I12 (use of two flowmeters)
2014-09-12 07:18:24 +02:00
Milan Hanajik
3559ab0ab3 - Elde.FlowMeterCouple component added
- LtrPerPulse and LtrPerPulseCorrected property/function added to IFlowMeter and flowmeters
2014-09-10 13:43:33 +02:00
Milan Hanajik
fcfdfeca41 - COmponent properties 'Position' --> 'Idx0' or 'Idx1'
- process data logging, RegulVal position logging
- changes for I11+I12, NOK yet
2014-09-10 12:05:49 +02:00
Milan Hanajik
d0ebb62ab3 - Component update (temp.)
- Process data logging, first trial
2014-09-09 16:18:23 +02:00
Milan Hanajik
354c13853f All PumpsWithFM are controlled when opening pumps at the test start 2014-09-09 09:14:47 +02:00
Milan Hanajik
d14cb175a6 FlowStableSec parameter added to RegulValve 2014-09-08 20:24:46 +02:00
Milan Hanajik
6eee83042b PmpWithFM and Transition sequences functionality implemented 2014-09-08 13:16:31 +02:00
Milan Hanajik
ea59dd0932 FlyingStart...Seq and CombinedMetersSeq sequences cleaned-up:
- Stop should work OK
- Target flow is tested and config error is shown in case it's NOK
- TestEnd sequence executed on Error
2014-08-15 14:32:03 +02:00
Milan Hanajik
596667a67e Default action and stopping the FM-controlled pump
moved to SequenceBase.Transition(sequence, context).
Sequences cleaned-up.
2014-08-14 09:06:01 +02:00
Milan Hanajik
e128784bb8 Sequences cleaned-up 2014-08-13 16:20:00 +02:00
Milan Hanajik
f4e7c7e88d Dnes koncim 2014-08-12 18:22:32 +02:00
Milan Hanajik
38a88e841b - Three tanks, balances, empty valves supported
- Code cleanup
2014-08-12 14:52:42 +02:00
Milan Hanajik
ffb4d5afb6 Koncim 8.8.14 2014-08-08 16:25:51 +02:00
Milan Hanajik
fd2db3e229 As sent to Munich 2014-08-01 08:36:17 +02:00
Milan Hanajik
836daaa5a1 - German translations
- IBox, FloatBox, IntBox related changes
2014-07-31 22:17:48 +02:00
Milan Hanajik
66feec63de Koncim: IBox, etc. 2014-07-31 17:04:09 +02:00
Milan Hanajik
9a9a09f16d TolerRed parameter premenovany a pouzity ako Filter 2014-07-31 00:50:42 +02:00
Milan Hanajik
175a92f633 Initial commit almost identical to SVN-repo rev.340 2014-07-28 09:56:40 +02:00