Commit Graph

90 Commits

Author SHA1 Message Date
Milan Hanajik
5f2da63339 Drain valve removed from Output path, outPath.Scale.DrainValve used instead of outPath.DrainValve, wait for Event. BalanceDone before 2nd mass measurement in FlyingStartMassCollection, ver. 2.12.519 2017-03-29 09:22:39 +02:00
Milan Hanajik
d420128b4b Draining modified, in BERLIN done always before flow setting, ver. 2.12.518 2017-03-28 23:54:52 +02:00
Milan Hanajik
38c199f6f9 Interfaces between Camera and Roi and sequences finalized, TODO: network communication, ver. 2.12.446
Sequences more robust for debugging, T and Pr-meters checked for null
2017-01-25 17:28:57 +01:00
Milan Hanajik
044e53f2b2 Changes under construction : ROI registration to Cameras, ver. 2.12.441 2017-01-24 12:34:52 +01:00
Milan Hanajik
2150ced11f Propagation of ROI parameters between ROI-s and Cameras implemented, ver. 2.12.438 2017-01-22 20:40:12 +01:00
Milan Hanajik
6d45b2c878 RoiDetectionSeq modified, ready to be tested. 2017-01-16 15:51:34 +01:00
Milan Hanajik
c73cf7002f Camera.Roi.MeasurementOp added, UDP listener added, PulsesPerLtr (and ProcedureParams) added, etc. 2017-01-16 13:49:29 +01:00
Milan Hanajik
89901c75f7 Revert "Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow."
This reverts commit be52e2df96.
2016-12-16 13:07:54 +01:00
Milan Hanajik
be52e2df96 Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow. 2016-12-12 16:43:04 +01:00
Milan Hanajik
216e08d57c Execute(...) arguments changed everywhere, repetitionNr usage depends on outerLoopMode, outerLoopCounter, ver. 2.12.412 2016-12-10 13:03:35 +01:00
Milan Hanajik
f3b178473c Outer loop logic added, TODO: (1) Begin-block and End-block test methods, (2) support in test method sequences 2016-12-10 11:33:31 +01:00
Milan Hanajik
bab677c5c2 PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373 2016-10-18 19:14:01 +02:00
Milan Hanajik
03c027ab33 LogProcessDataHeatMeters, ver. 2.11.371 2016-10-18 11:49:32 +02:00
Milan Hanajik
b3a2c3a0fc FlyingStart, FlyingStartMassCollection and CombinedWithDetection methods support Simulation mode, ver. 2.10.360 2016-10-11 12:53:17 +02:00
Milan Hanajik
438028506e Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow) 2016-10-07 16:22:36 +02:00
Milan Hanajik
7df9333fba Statistics return doubles instead of float, casting is done just when writing to entities. 2016-10-07 14:46:14 +02:00
Milan Hanajik
4160420844 Masses are stored in double variables everywhere. 2016-10-07 14:06:54 +02:00
Milan Hanajik
2286877fad Test method names cleaned up. 2016-09-26 11:08:16 +02:00
Milan Hanajik
0426d2510a Energy and RefEnergy added to ResultsDB, First/Last/Min/Max of all three ambient values added to TestRslt, ver. 2.10.340 2016-08-19 15:37:00 +02:00
Milan Hanajik
8dae45e10e IComponentCfg and IComponentFactory interfaces and all derived classes modified. 2016-08-05 14:32:36 +02:00
Milan Hanajik
111e3d8647 Minimum and maximum (reference) flow during a test calculated and saved to Results.Entities.TestRslt. 2016-08-02 14:48:18 +02:00
Milan Hanajik
ac1bdbe476 Bug fix: Updating water meter results in case of a test with parts, copes also with single meters/multiple lines. 2016-06-30 14:03:51 +02:00
Milan Hanajik
799fda63e9 Bug fix : Updating water meters results in case of test with 'parts'. 2016-06-30 12:55:35 +02:00
Milan Hanajik
1337fff2dc Fixed: (1) STOP button does not function in FlyingStart and FlyingStartMassCollection methods, (2) Results.Entities.WaterMeterData.Equals(.) 2016-06-15 17:04:25 +02:00
Milan Hanajik
9a725de4a9 Stable mass measurement rewritten, it can use immediate measurement, DB change, ver.2.5.265. 2016-04-14 17:03:33 +02:00
Milan Hanajik
e037720115 iPerlST: Logging of a STOP command via UI. 2016-04-14 09:16:20 +02:00
Milan Hanajik
462ed568de Bug fixes: (1) simulation, (2) when BenchInfo==null, (3) ProcessData.RefPulses updated, (4) ProcessTabPages, etc. 2016-02-15 22:48:44 +01:00
Milan Hanajik
edc4d59f90 Process data screen update when test completed, version 2.1.213. 2016-02-13 19:28:33 +01:00
Milan Hanajik
6a159f773e WMPulses[], WMRefPulses[], WMTimes[] removed from SequenceBase, operations, etc., clean-up. 2016-02-13 17:39:38 +01:00
Milan Hanajik
3946d26cb4 IRegisterReader extended, ReadReferenceForRegisterOp removed, ReadRegisteOp integrated into RegisterReader class, ProcessTabPages updated. 2016-02-13 15:02:10 +01:00
Milan Hanajik
7534fc7c24 Removed WMPulses and WMRefPulses logs. 2016-02-13 08:11:50 +01:00
Milan Hanajik
2c1e4e7d26 Process data display : many changes, TODO: Meter data and the end of test. 2016-02-10 19:24:10 +01:00
Milan Hanajik
98c8b0e7a8 iPearl debugging, progress management, OracleDB simulation, etc, version 2.1.182 2016-01-09 20:06:59 +01:00
Milan Hanajik
e14dc37060 TestCompletedEventArgs modification 2016-01-04 16:03:17 +01:00
Milan Hanajik
26982a5729 Many changes, new results used, all test sequences modified, simulated tests rewritten. 2016-01-04 13:53:45 +01:00
Milan Hanajik
61bfa51fa7 Uncertainty used when evaluating tests, in TestWizard, UI, etc., version 2.1.171. 2016-01-02 11:11:45 +01:00
Milan Hanajik
bb2087c002 ProcessData base class with 'public static' process data introduced. 2015-12-20 20:48:50 +01:00
Milan Hanajik
f6cec9d769 'Config', 'Results' projects added, includes iPerl opto logging bug-fixes, builds OK, cannot open DB, version 2.0.158. 2015-12-05 14:18:36 +01:00
Milan Hanajik
d7c262c87a Emptying the tank displays remaining time in min and sec. 2015-10-14 15:45:51 +02:00
Milan Hanajik
72754ebe10 Flow control during a test, version 1.5.121. 2015-09-22 18:39:00 +02:00
Milan Hanajik
d7e6a69ca9 StartMeasurementOp interface changed: OutputPath is the first argment 2015-09-22 17:03:26 +02:00
Milan Hanajik
120c1cc39d Remaining test time is shown in minutes and seconds. 2015-09-22 11:35:44 +02:00
Milan Hanajik
d041cd1d20 Evaluate and Publish properties of test methods changed to stateless functions Evaluate(test) and Publish(test), this fixes results, version 1.5.107 2015-09-06 22:21:54 +02:00
Milan Hanajik
cb4833664c Clone( ) function added to IParamsProvider and all procedure/test parameters classes. 2015-09-05 12:18:09 +02:00
Milan Hanajik
33963ec8cf Version 1.5.84. Reading registers, scales, temperature, pressure, ... during test done in one state in the sequence.
Many changes in TestMethods.iPerlCommunication and WaterMeters.iPerl.WaterMeter. iPerl measurement with opto-data works OK.
Logging in State changed, ...
2015-08-19 13:04:47 +02:00
Milan Hanajik
f85fbd0b55 Problems when passing flowmeter/diverter info to test start by SendCommand() fixed, version 1.5.77. 2015-08-14 18:14:08 +02:00
Milan Hanajik
95c05078de Introduction of Program.CompoundWMsCount, fix in DataEntry.Combined.CycleBeginningForm, version 1.5.68. 2015-07-09 16:24:55 +02:00
Milan Hanajik
7b902e8ca3 IComponentFactory.DummyComponent() interface function added and implemented in all components. 2015-06-29 11:14:33 +02:00
Milan Hanajik
0cea24246c Error message due to incorrect configuration is cleared after selecting another procedure/test.
Return value from WaitBeginFormClosed(..) changed from bool to enum UIFlowControl.
2015-06-25 04:48:28 +02:00
Milan Hanajik
edb6d5e8b6 'EndCondiiton' and 'Communication' added to TransitionStep (transition sequence). TODO: EndConditions functionality, version 1.5.44 2015-05-22 11:21:56 +02:00