Commit Graph

61 Commits

Author SHA1 Message Date
Milan Hanajik
5f2da63339 Drain valve removed from Output path, outPath.Scale.DrainValve used instead of outPath.DrainValve, wait for Event. BalanceDone before 2nd mass measurement in FlyingStartMassCollection, ver. 2.12.519 2017-03-29 09:22:39 +02:00
Milan Hanajik
d420128b4b Draining modified, in BERLIN done always before flow setting, ver. 2.12.518 2017-03-28 23:54:52 +02:00
Milan Hanajik
89901c75f7 Revert "Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow."
This reverts commit be52e2df96.
2016-12-16 13:07:54 +01:00
Milan Hanajik
be52e2df96 Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow. 2016-12-12 16:43:04 +01:00
Milan Hanajik
216e08d57c Execute(...) arguments changed everywhere, repetitionNr usage depends on outerLoopMode, outerLoopCounter, ver. 2.12.412 2016-12-10 13:03:35 +01:00
Milan Hanajik
98a773700e Bug fix related to PressMtrDelta, ver. 2.12.386 2016-11-17 08:48:52 +01:00
Milan Hanajik
bab677c5c2 PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373 2016-10-18 19:14:01 +02:00
Milan Hanajik
03c027ab33 LogProcessDataHeatMeters, ver. 2.11.371 2016-10-18 11:49:32 +02:00
Milan Hanajik
438028506e Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow) 2016-10-07 16:22:36 +02:00
Milan Hanajik
7df9333fba Statistics return doubles instead of float, casting is done just when writing to entities. 2016-10-07 14:46:14 +02:00
Milan Hanajik
4160420844 Masses are stored in double variables everywhere. 2016-10-07 14:06:54 +02:00
Milan Hanajik
0426d2510a Energy and RefEnergy added to ResultsDB, First/Last/Min/Max of all three ambient values added to TestRslt, ver. 2.10.340 2016-08-19 15:37:00 +02:00
Milan Hanajik
111e3d8647 Minimum and maximum (reference) flow during a test calculated and saved to Results.Entities.TestRslt. 2016-08-02 14:48:18 +02:00
Milan Hanajik
1337fff2dc Fixed: (1) STOP button does not function in FlyingStart and FlyingStartMassCollection methods, (2) Results.Entities.WaterMeterData.Equals(.) 2016-06-15 17:04:25 +02:00
Milan Hanajik
9a725de4a9 Stable mass measurement rewritten, it can use immediate measurement, DB change, ver.2.5.265. 2016-04-14 17:03:33 +02:00
Milan Hanajik
e037720115 iPerlST: Logging of a STOP command via UI. 2016-04-14 09:16:20 +02:00
Milan Hanajik
462ed568de Bug fixes: (1) simulation, (2) when BenchInfo==null, (3) ProcessData.RefPulses updated, (4) ProcessTabPages, etc. 2016-02-15 22:48:44 +01:00
Milan Hanajik
edc4d59f90 Process data screen update when test completed, version 2.1.213. 2016-02-13 19:28:33 +01:00
Milan Hanajik
6a159f773e WMPulses[], WMRefPulses[], WMTimes[] removed from SequenceBase, operations, etc., clean-up. 2016-02-13 17:39:38 +01:00
Milan Hanajik
7534fc7c24 Removed WMPulses and WMRefPulses logs. 2016-02-13 08:11:50 +01:00
Milan Hanajik
2c1e4e7d26 Process data display : many changes, TODO: Meter data and the end of test. 2016-02-10 19:24:10 +01:00
Milan Hanajik
3407b51c27 All changes done for Badger-velka-trat merged into this branch, version 2.1.210. 2016-02-07 22:55:48 +01:00
Milan Hanajik
98c8b0e7a8 iPearl debugging, progress management, OracleDB simulation, etc, version 2.1.182 2016-01-09 20:06:59 +01:00
Milan Hanajik
e14dc37060 TestCompletedEventArgs modification 2016-01-04 16:03:17 +01:00
Milan Hanajik
26982a5729 Many changes, new results used, all test sequences modified, simulated tests rewritten. 2016-01-04 13:53:45 +01:00
Milan Hanajik
61bfa51fa7 Uncertainty used when evaluating tests, in TestWizard, UI, etc., version 2.1.171. 2016-01-02 11:11:45 +01:00
Milan Hanajik
bb2087c002 ProcessData base class with 'public static' process data introduced. 2015-12-20 20:48:50 +01:00
Milan Hanajik
f6cec9d769 'Config', 'Results' projects added, includes iPerl opto logging bug-fixes, builds OK, cannot open DB, version 2.0.158. 2015-12-05 14:18:36 +01:00
Milan Hanajik
72754ebe10 Flow control during a test, version 1.5.121. 2015-09-22 18:39:00 +02:00
Milan Hanajik
d7e6a69ca9 StartMeasurementOp interface changed: OutputPath is the first argment 2015-09-22 17:03:26 +02:00
Milan Hanajik
33963ec8cf Version 1.5.84. Reading registers, scales, temperature, pressure, ... during test done in one state in the sequence.
Many changes in TestMethods.iPerlCommunication and WaterMeters.iPerl.WaterMeter. iPerl measurement with opto-data works OK.
Logging in State changed, ...
2015-08-19 13:04:47 +02:00
Milan Hanajik
f85fbd0b55 Problems when passing flowmeter/diverter info to test start by SendCommand() fixed, version 1.5.77. 2015-08-14 18:14:08 +02:00
Milan Hanajik
0cea24246c Error message due to incorrect configuration is cleared after selecting another procedure/test.
Return value from WaitBeginFormClosed(..) changed from bool to enum UIFlowControl.
2015-06-25 04:48:28 +02:00
Milan Hanajik
edb6d5e8b6 'EndCondiiton' and 'Communication' added to TransitionStep (transition sequence). TODO: EndConditions functionality, version 1.5.44 2015-05-22 11:21:56 +02:00
Milan Hanajik
cd9042a648 PulsesPerLiter added to Entities.MeterTestResult and to result items. Version 1.4.36
More times added to Entities.Test (TimeBeforeFlow, TimeFlow2Mass, TimeMass2Start, TimeStop2Mass).
Activity display fixed in FlyingStartCollectionMethod.
2015-05-19 15:38:58 +02:00
Milan Hanajik
39eb2cfd57 Entry form related improvements / bugfixes (Fixed start collection method related). 2015-04-28 15:27:47 +02:00
Milan Hanajik
be78bb5ce0 Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
Milan Hanajik
1e63ded8e1 MetersKind.Standard in TBF/Entities/Enums.cs reverted to MetersKind.Single 2015-03-25 05:35:05 +01:00
Milan Hanajik
7dce565e4f MetersKind.Single in TBF/Entities/Enuns.cs renamed to MetersKind.Standard 2015-03-25 02:31:28 +01:00
Milan Hanajik
c005a5cb26 Solves issue with an opened CycleBeginForm after abort and re-selection in Israel:
- CloseCycleBeginForm() -> WaitBeginFormClosed()
- CloseBeginForm() added to SequenceBase(forced dialog close)
- CloseModellFormHandler added to UiBridge.Bridge
2015-03-01 11:13:26 +01:00
Milan Hanajik
0c9408ff64 More configuration checks when starting a test 2015-02-02 23:18:28 +01:00
Milan Hanajik
9bd5fba6dc (1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik
e1756f692c Confirmed results to SummaryResults.txt logger 2015-02-02 11:38:42 +01:00
Milan Hanajik
56a9a7cf1b Test results are written into database after confirming with END 2015-02-02 00:08:47 +01:00
Milan Hanajik
ce6214f631 Zapne pumpu pred vypustanim aj pri ostatnych metodach 2015-02-01 19:30:00 +01:00
Milan Hanajik
5cf5fe5eba CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change) 2015-01-25 08:11:40 +01:00
Milan Hanajik
d3532a2796 PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
bb31cdae56 Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results 2015-01-15 06:34:36 +01:00
Milan Hanajik
9c1db2778e Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page 2015-01-15 03:16:14 +01:00
Milan Hanajik
34dc592e59 Timeout while setting the water flow handled correctly: message displayed, test aborted 2015-01-12 05:56:19 +01:00