Commit Graph
82 Commits
Author SHA1 Message Date
Milan Hanajik 33963ec8cf Version 1.5.84. Reading registers, scales, temperature, pressure, ... during test done in one state in the sequence.
Many changes in TestMethods.iPerlCommunication and WaterMeters.iPerl.WaterMeter. iPerl measurement with opto-data works OK.
Logging in State changed, ...
2015-08-19 13:04:47 +02:00
Milan Hanajik 5db53ca6e3 Generic improvements: process page fixes, error format F2 or F3 (master), results page fixes, Comet ambient serial parameters (comment). 2015-08-16 19:58:43 +02:00
Milan Hanajik 7c1b713780 Zapiska and WaterMeterPL added, BenchInfo.Polska added, IBenchInfo infroduced, Version 1.5.74 2015-08-02 14:09:24 +02:00
Milan Hanajik 0cea24246c Error message due to incorrect configuration is cleared after selecting another procedure/test.
Return value from WaitBeginFormClosed(..) changed from bool to enum UIFlowControl.
2015-06-25 04:48:28 +02:00
Milan Hanajik 04196fde2f 'Break' button added to the main window, replaces 'Try heads' button. 2015-05-22 16:43:17 +02:00
Milan Hanajik edf35edfba EndCondition in transition steps is checked. Transition steps are finished when tank is empty. 2015-05-22 12:31:10 +02:00
Milan Hanajik edb6d5e8b6 'EndCondiiton' and 'Communication' added to TransitionStep (transition sequence). TODO: EndConditions functionality, version 1.5.44 2015-05-22 11:21:56 +02:00
Milan Hanajik ceb3de90bf Invalid configuration checked in StateMachine.GetPaths(...). More logging of mass display. 2015-05-20 16:18:54 +02:00
Milan Hanajik ab112e3e04 ReadMassesOp operation corrected. Works with both scales (Standard/Multi) 2015-05-07 18:31:46 +02:00
Milan Hanajik 21d0adb089 MettlerToledo scales moved one level down in the directory and namespace structure. 2015-05-07 16:11:07 +02:00
Milan Hanajik 6a11980d69 After a cycle or a test stop serial numbers are not queried for the 2nd time. Version = 1.3.24 2015-04-29 13:53:36 +02:00
Milan Hanajik 39eb2cfd57 Entry form related improvements / bugfixes (Fixed start collection method related). 2015-04-28 15:27:47 +02:00
Milan Hanajik 7b6c23f3b2 Printing Purchase orders always in landscape OK. Version 1.3.16.
Printing at the end of cycle can be switched off - Supress printing parameter of ResultsPrinter.Basic component.
2015-04-19 16:49:43 +02:00
Milan Hanajik f73863f758 Fixing behavior when more FM pumps share the same bit in Fuzhou300. More logging. 2015-04-18 13:31:31 +02:00
Milan Hanajik be78bb5ce0 Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
Milan Hanajik 854a2e90c1 Bux fixes: DataEntry.Standard form for fixed start method, modeless form closing. 2015-04-14 11:20:48 +02:00
Milan Hanajik a26c90f217 Mass values are printed out using format specified by Balance component parameters 2015-03-25 10:01:37 +01:00
Milan Hanajik fb1ddad3b8 One more bug fix in modeless data entry forms. 2015-03-08 15:13:50 +01:00
Milan Hanajik c005a5cb26 Solves issue with an opened CycleBeginForm after abort and re-selection in Israel:
- CloseCycleBeginForm() -> WaitBeginFormClosed()
- CloseBeginForm() added to SequenceBase(forced dialog close)
- CloseModellFormHandler added to UiBridge.Bridge
2015-03-01 11:13:26 +01:00
Milan Hanajik 9fa72109da Fixed bugs:
- when there is a configuration error in a test and Data entry form for s/n-s was not closed yet
- when showing results with a combination of different tests
2015-02-21 20:03:33 +01:00
Milan Hanajik 08e53c090e PMaxTest and LeakTest improvements:
- result items P_xy_start and P_xy_end added
- DurationLeak test parameter for LeakTest method
- correct default parameters for Danfoss.VLT2800.Pump (FC protocol)
- bug fixes
2015-02-20 13:07:21 +01:00
Milan Hanajik 1dbbe31eae Bug fix for the case of combined WM test and odd total nr. of watermeters (Munich) 2015-02-18 14:49:19 +01:00
Milan Hanajik 558cfb8c6e Bug fix in saving test results 2015-02-07 21:21:43 +01:00
Milan Hanajik 0c9408ff64 More configuration checks when starting a test 2015-02-02 23:18:28 +01:00
Milan Hanajik 9bd5fba6dc (1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik 3e48e4c50c Printed header correctly scaled, bugfix in saving results into DB/Summary 2015-02-02 15:04:48 +01:00
Milan Hanajik e1756f692c Confirmed results to SummaryResults.txt logger 2015-02-02 11:38:42 +01:00
Milan Hanajik 376056fb1a Results to database consolidated, 1-based WMNr used in printing, saving 2015-02-02 10:35:15 +01:00
Milan Hanajik 56a9a7cf1b Test results are written into database after confirming with END 2015-02-02 00:08:47 +01:00
Milan Hanajik 806f4efe6a Results printing and saving uses Publish property of GenericDevices.ITestMethod 2015-02-01 16:20:27 +01:00
Milan Hanajik ae5abde1e6 Results printing and saving improced, correct order of tests, etc. 2015-02-01 13:43:04 +01:00
Milan Hanajik 5cf5fe5eba CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change) 2015-01-25 08:11:40 +01:00
Milan Hanajik d3532a2796 PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik 2b6b569dee Process log format changes: flow with 4 valid digits, Et. -> Ref. 2015-01-16 03:09:39 +01:00
Milan Hanajik 5a2d7f09ce CycleBeginForm is opened earlier, immediately after procedure selection, before purging 2015-01-16 03:09:37 +01:00
Milan Hanajik bb31cdae56 Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results 2015-01-15 06:34:36 +01:00
Milan Hanajik 11bdb1b2f1 Bugfix in MainSeq (opening EntryForm instead of closing) 2015-01-15 05:03:46 +01:00
Milan Hanajik 49a004d7fe DataEntry dlg at the beginning closes at the end of the 1st test (at the latest) 2015-01-15 03:51:33 +01:00
Milan Hanajik 9c1db2778e Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page 2015-01-15 03:16:14 +01:00
Milan Hanajik 0829655880 Messages and Errors display is supported, transition messages are displayed now 2015-01-12 04:53:50 +01:00
Milan Hanajik 11f8343a1d Bug fix in purging sequence when no RV-s 2015-01-08 08:05:23 +01:00
Milan Hanajik 752719bd62 Getting rid of and suppressing WARNING messages 2014-12-31 13:44:47 +01:00
Milan Hanajik 8ef0cea1ff One more change in transition sequences with more RV-s changed in one step 2014-12-28 09:08:39 +01:00
Milan Hanajik 4794000f75 Fixed a bug in transition sequences with more RV-s changed in one step 2014-12-12 13:57:24 +01:00
Milan Hanajik ea6c9818cf - Tank emptying remaining time indication
- Bug fixed: When copying a procwdure ItemId was not correctly set, remained 0
- Always create a message log when device initialization is completed successfully
2014-12-10 22:39:53 +01:00
Milan Hanajik 42c255e40e More changes in VirtualBench drawing on the Process screen 2014-12-10 17:14:03 +01:00
Milan Hanajik 415adba8cf - Tank emptying on start-up implemented, EmptyTimeSec parameter added to Balances
- added events Event.TimerBusy, Event.ValvesBusy, etc.
- fixed bug in SetValvesOp
- preparing a virtual bench drawing on the Process screen - partly done
2014-12-10 12:37:05 +01:00
Milan Hanajik 930db8c379 - many process tab page improvements
- program start and state changes logging improved
- IDC100 measurement related changes: reference pulses in RegisterReader
- etc
2014-10-02 20:56:24 +02:00
Milan Hanajik 2f6f24e281 As sent to ST for the last test on Fuzhou300 system
- new component with VZ15 and modified position of VZ13
- fixed start method evaluation OK
- handling of entry forms cleaned-up
2014-09-23 13:16:59 +02:00
Milan Hanajik b1f7730b96 - FixedStartMassCollection method ready to be tested
- FlyingStart method (without mass collection) flow corrections fixed
- DataEntry/WMStates data entry forms added (used by FixedStartMassCollection method)
- minor changes
2014-09-16 21:05:54 +02:00