Milan Hanajik 3b1f0129ba Bug fixed in Disabled watermeters will not appear in results...
When there were no results yet and Results screen was opened -> crash
2015-03-25 07:54:49 +01:00
Milan Hanajik 4f0ec7eb68 Version number and build date displayed in the main window title and AboutDlg. 2015-03-25 07:53:52 +01:00
Milan Hanajik 1e63ded8e1 MetersKind.Standard in TBF/Entities/Enums.cs reverted to MetersKind.Single 2015-03-25 05:35:05 +01:00
Milan Hanajik 23d5e6d19d Disabled watermeters will not appear in results (screen, ResultsPrinters.Basic and ResultsWriters.Basic).
Updating Disabled (default = false) is provided by DataEntry.Standard when entering serial numbers.
2015-03-25 03:57:46 +01:00
Milan Hanajik 7dce565e4f MetersKind.Single in TBF/Entities/Enuns.cs renamed to MetersKind.Standard 2015-03-25 02:31:28 +01:00
Milan Hanajik f524186b70 More DataEntry.Standard related changes 2015-03-25 02:14:42 +01:00
Milan Hanajik dc9577eaa0 Test methods for standard watermeter use IWatermeter.Disabled flag to remove non-existing meter results 2015-03-24 10:11:20 +01:00
Milan Hanajik d1e9537610 DataEntry.Standard (with checkBoxes) and DataEntry.Combined entry forms added.
IWaterMeter.Disabled supported.
2015-03-24 10:09:47 +01:00
Milan Hanajik 2902f36332 Work in progress: Diverter calibration 2015-03-24 02:45:36 +01:00
Milan Hanajik 1c46002aaa Regulation valve calibration fixed (feedback from ADC) 2015-03-24 02:45:09 +01:00
Milan Hanajik 4dfa98ff89 EtCalib[] array size for Torino corrected, index checked when accessing the array. 2015-03-24 02:44:13 +01:00
Milan Hanajik 3c7b3ad0b8 Torino50 component updated: oprava okolo VL13. 2015-03-23 04:11:50 +01:00
Milan Hanajik b761cea5f2 Torino50 component updated 2015-03-10 19:16:20 +01:00
Milan Hanajik 6305c42f8b More program extensions to handle TORINO50 define. 2015-03-09 17:30:38 +01:00
Milan Hanajik 82d5e7df05 Fix 2015-03-09 16:32:39 +01:00
Milan Hanajik c2bccda07f Program extensions to handle TORINO50 define. 2015-03-09 15:47:59 +01:00
Milan Hanajik e772823572 Creating a database, a block of code commented out. 2015-03-09 15:26:44 +01:00
Milan Hanajik a387e8c70f Component for Torino PT50 added. 2015-03-08 15:17:47 +01:00
Milan Hanajik fb1ddad3b8 One more bug fix in modeless data entry forms. 2015-03-08 15:13:50 +01:00
Milan Hanajik 9e28856229 Bug fixes in modeless data entry forms. 2015-03-08 09:05:40 +01:00
Milan Hanajik c005a5cb26 Solves issue with an opened CycleBeginForm after abort and re-selection in Israel:
- CloseCycleBeginForm() -> WaitBeginFormClosed()
- CloseBeginForm() added to SequenceBase(forced dialog close)
- CloseModellFormHandler added to UiBridge.Bridge
2015-03-01 11:13:26 +01:00
Milan Hanajik fc30e160fc - Unhandled exception handler added - it creates a log message.
- config.backup.xml file created and used in case config.xml is corrupted
- LocalSettings.Assign() function avoided
- static LocalSettins LocalSettings.Load(string fname) returns a reference to settings
2015-03-01 06:26:51 +01:00
Milan Hanajik 9fa72109da Fixed bugs:
- when there is a configuration error in a test and Data entry form for s/n-s was not closed yet
- when showing results with a combination of different tests
2015-02-21 20:03:33 +01:00
Milan Hanajik 82a72670a6 Remaining time displayed for all tests 2015-02-21 20:03:33 +01:00
Milan Hanajik 08e53c090e PMaxTest and LeakTest improvements:
- result items P_xy_start and P_xy_end added
- DurationLeak test parameter for LeakTest method
- correct default parameters for Danfoss.VLT2800.Pump (FC protocol)
- bug fixes
2015-02-20 13:07:21 +01:00
Milan Hanajik 286bd13eb8 Fiirst version of ResultsBrowser added 2015-02-20 09:44:35 +01:00
Milan Hanajik 371b4a9fbb Build-in power users implemented 2015-02-20 03:58:14 +01:00
Milan Hanajik 6aa63e8277 Some german translations added 2015-02-19 15:55:38 +01:00
Milan Hanajik b07c7c5c9d PMaxTest and LeakTest methods implemented, added to the project
Order of two new test wizard dialog exchanged
Pressure Selection wizard dialog added
2015-02-19 15:54:55 +01:00
Milan Hanajik 93fd6a4f42 Support for FC protocol for Danfoss-VLT2800 and associated valve added - control part 2015-02-18 22:50:44 +01:00
Milan Hanajik abd636b137 Checksum calculation for telegrams added, Telegram class added 2015-02-18 18:05:32 +01:00
Milan Hanajik 5e4eec4d70 Support for FC protocol for Danfoss-VLT2800 added - UI Part 2015-02-18 16:19:37 +01:00
Milan Hanajik 1dbbe31eae Bug fix for the case of combined WM test and odd total nr. of watermeters (Munich) 2015-02-18 14:49:19 +01:00
Milan Hanajik fbdd937302 Munich component updated 2015-02-18 13:12:12 +01:00
Milan Hanajik 2ca36374e6 Danfoss-VLT2800-Pump functions OK, TODO: control the valve of the pump 2015-02-16 21:01:37 +01:00
Milan Hanajik 50cd1c5d4f Files for Danfoss-VLT800-Pump added to the repository, builds OK 2015-02-16 13:36:22 +01:00
Milan Hanajik 6eb384283a Regul. valve calibration uses 2 sec. pulses 2015-02-10 09:01:30 +01:00
Milan Hanajik 1f590a71f5 Correct handling of up/down selection moves in TransitionStepsCtrl and VirtualBenchSteps
Exception not used during updates (when duration is invalid)
Minor resource change
2015-02-08 00:09:02 +01:00
Milan Hanajik 558cfb8c6e Bug fix in saving test results 2015-02-07 21:21:43 +01:00
Milan Hanajik 0b5d342dfc TODO list updated 2015-02-03 12:52:44 +01:00
Milan Hanajik 338a1f2d49 Cycle nr changed to Batch nr in printouts, saved data 2015-02-03 11:08:12 +01:00
Milan Hanajik 64253e1985 (1) RegulValveTandem wont appear in transition sequences, (2) Fixed RegulValveTandem initialization 2015-02-03 10:53:02 +01:00
Milan Hanajik 5806a65a0c RegulValveTandem op SetFlowOp should be functional, to be tested 2015-02-03 10:30:24 +01:00
Milan Hanajik ab8aa61a29 Initial version with config UI, w/o functionality, added to the project 2015-02-03 08:06:20 +01:00
Milan Hanajik 0c9408ff64 More configuration checks when starting a test 2015-02-02 23:18:28 +01:00
Milan Hanajik 94aa744fd4 Range of RegulValve indexes changed to 1..8, there are 6 RV-s in Pt200il 2015-02-02 22:49:08 +01:00
Milan Hanajik 9876297953 Printing of Qrise/Qfall results modified, '-' printed instead of '0' 2015-02-02 22:46:07 +01:00
Milan Hanajik d3a07bff44 Utils.FloatToStr(value, validDigits) modified, rounding taken into account 2015-02-02 22:44:34 +01:00
Milan Hanajik 9bd5fba6dc (1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik 3e48e4c50c Printed header correctly scaled, bugfix in saving results into DB/Summary 2015-02-02 15:04:48 +01:00
Milan Hanajik 3b66d4c4f7 Default valaues for Test and Procedure parameters in their constructors 2015-02-02 14:45:06 +01:00
Milan Hanajik e1756f692c Confirmed results to SummaryResults.txt logger 2015-02-02 11:38:42 +01:00
Milan Hanajik 376056fb1a Results to database consolidated, 1-based WMNr used in printing, saving 2015-02-02 10:35:15 +01:00
Milan Hanajik 56a9a7cf1b Test results are written into database after confirming with END 2015-02-02 00:08:47 +01:00
Milan Hanajik ce6214f631 Zapne pumpu pred vypustanim aj pri ostatnych metodach 2015-02-01 19:30:00 +01:00
Milan Hanajik 57a7510d05 Center stripe in the Error dialog of the Adjustment method 2015-02-01 19:28:26 +01:00
Milan Hanajik 7e8dfd472d Zapne pumpu pred vypustanim 2015-02-01 18:53:09 +01:00
Milan Hanajik 6dbff5978a Pokus 2015-02-01 17:14:50 +01:00
Milan Hanajik 806f4efe6a Results printing and saving uses Publish property of GenericDevices.ITestMethod 2015-02-01 16:20:27 +01:00
Milan Hanajik 0238a96975 More comments in SetFlowOp 2015-02-01 15:07:15 +01:00
Milan Hanajik ae5abde1e6 Results printing and saving improced, correct order of tests, etc. 2015-02-01 13:43:04 +01:00
Milan Hanajik 8009774c20 Bugfixes: FM pumps % interpretation after adding a pump, Tabs order in entry forms 2015-02-01 11:04:05 +01:00
Milan Hanajik efa14c6ebb Adjustment results will not be printed, shown, etc. 2015-02-01 08:20:13 +01:00
Milan Hanajik 0c4da37e85 Adjustment: Graphics added, to be tested 2015-01-28 22:14:30 +01:00
Milan Hanajik 5653628bf7 Adjust: Larger font, place for graphics 2015-01-28 20:57:03 +01:00
Milan Hanajik 94accbf58b Bugfix: Adjustment method modeless dialog was not started in UI thread, freezes 2015-01-28 19:33:02 +01:00
Milan Hanajik cca60e56ff Yet one more change - adjust 2015-01-28 19:03:00 +01:00
Milan Hanajik 508f47cb6b Adjustment test method ready for tests 2015-01-28 18:18:46 +01:00
Milan Hanajik 6a3e3e7682 Layout changes, c:/TBF/header.png used 2015-01-28 07:24:03 +01:00
Milan Hanajik 545cce6d11 Printed and Saved basic results output improved 2015-01-27 23:02:34 +01:00
Milan Hanajik 85bb34030a Bugfix in Fixed start method when configuration is NOK, no Dummy RR-s
Bugfix in FIxed start method Entry form when config.is NOK, WM-s are missing
2015-01-27 23:00:42 +01:00
Milan Hanajik 0b7c6a0fed First version of Basic printing (one page only) 2015-01-27 02:37:24 +01:00
Milan Hanajik c89549a0ae Pump power can be an arbitrary integer from 0 to 100, drop-down list changed 2015-01-26 16:03:11 +01:00
Milan Hanajik 8aa9ed9f21 Bugfix for PT200IL: Test does not complete, Status bits definition changed 2015-01-26 13:15:47 +01:00
Milan Hanajik c3f64215f1 ProtocolTitle added to 'Procedure' and 'TestResult'. ResultsWriter-Basic rewritten 2015-01-25 23:43:17 +01:00
Milan Hanajik 5cf5fe5eba CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change) 2015-01-25 08:11:40 +01:00
Milan Hanajik dc57c1464b Component for PT200 Izrael updated after a visit to Fuzhou 2015-01-25 08:09:59 +01:00
Milan Hanajik 3393827653 Configuration of result items for device=harddisk added 2015-01-18 11:22:53 +01:00
Milan Hanajik ad665e5f0b Combined meters measurement corrections, Q_rise and Q_fall in results 2015-01-17 08:57:50 +01:00
Milan Hanajik cfd812eab6 Test-Part used when printing results on screen 2015-01-17 08:09:49 +01:00
Milan Hanajik bd1eb31f37 (1) ResultsConfig bug fixed, (2) UI for setting the Test parameter PumpPower, Parameters tab page 2015-01-17 06:34:24 +01:00
Milan Hanajik d3532a2796 PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik a0fb8000f0 PumpTandem can also be used as one of pumps in the tandem, PumpTandems can be chained 2015-01-16 07:40:04 +01:00
Milan Hanajik b1c9e0d3b5 Bugfixes: (1) PumpTandem was missing a Mask to be used as Valve, (2) Column widths in results screen 2015-01-16 07:08:26 +01:00
Milan Hanajik e07cf3c5d3 PumpTandem implemented for the case of two FM pumps with equal distribution of power 2015-01-16 05:24:34 +01:00
Milan Hanajik 6e75926d0b E_ref, T_amb, P_amb, H_amb were added to possible result items 2015-01-16 03:41:23 +01:00
Milan Hanajik 8b392016c2 Updated component for Fuzhou300: Corrected behavior of valves VM, etc 2015-01-16 03:18:49 +01:00
Milan Hanajik ade156be5c Column withs on the results screen can be saved and reused for all LIstView-s/watermeters 2015-01-16 03:09:41 +01:00
Milan Hanajik 2b6b569dee Process log format changes: flow with 4 valid digits, Et. -> Ref. 2015-01-16 03:09:39 +01:00
Milan Hanajik 5a2d7f09ce CycleBeginForm is opened earlier, immediately after procedure selection, before purging 2015-01-16 03:09:37 +01:00
Milan Hanajik bb31cdae56 Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results 2015-01-15 06:34:36 +01:00
Milan Hanajik 44b1f77b70 Process screen layout changed to fit 6 meter w/o overlaps, no functionality change 2015-01-15 05:45:40 +01:00
Milan Hanajik 11bdb1b2f1 Bugfix in MainSeq (opening EntryForm instead of closing) 2015-01-15 05:03:46 +01:00
Milan Hanajik 49a004d7fe DataEntry dlg at the beginning closes at the end of the 1st test (at the latest) 2015-01-15 03:51:33 +01:00
Milan Hanajik a697b7a4dc Access levels to procedures and tests changed: TestingSpecialist has access 2015-01-15 03:17:04 +01:00
Milan Hanajik 9c1db2778e Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page 2015-01-15 03:16:14 +01:00
Milan Hanajik 1c3c90e171 CombinedMeters and CombinedWithDetection support SupressTrils bool parameter
Warnings 'Unreachable code' supressed in DataEntries
2015-01-14 05:33:51 +01:00
Milan Hanajik 5a4df5593a (1) Passed/Failed with color in the on-screen results
(2) Error of main and aux. combined watermeters calculated and can be used in results
(3) Bugfix: no zero reference exception when the list of results items is empty
2015-01-14 03:19:12 +01:00
Milan Hanajik 00b937553c Localization via strings table added to DataEntry.Munich3 (accepts 6 single WM-s) 2015-01-13 09:12:40 +01:00
Milan Hanajik 1f489a481c Entry form DataEntry.Munich modified so that it accepts up to 3 combined WM-s 2015-01-13 08:46:32 +01:00