Commit Graph

38 Commits

Author SHA1 Message Date
Milan Hanajik
e14dc37060 TestCompletedEventArgs modification 2016-01-04 16:03:17 +01:00
Milan Hanajik
26982a5729 Many changes, new results used, all test sequences modified, simulated tests rewritten. 2016-01-04 13:53:45 +01:00
Milan Hanajik
61bfa51fa7 Uncertainty used when evaluating tests, in TestWizard, UI, etc., version 2.1.171. 2016-01-02 11:11:45 +01:00
Milan Hanajik
bb2087c002 ProcessData base class with 'public static' process data introduced. 2015-12-20 20:48:50 +01:00
Milan Hanajik
f6cec9d769 'Config', 'Results' projects added, includes iPerl opto logging bug-fixes, builds OK, cannot open DB, version 2.0.158. 2015-12-05 14:18:36 +01:00
Milan Hanajik
72754ebe10 Flow control during a test, version 1.5.121. 2015-09-22 18:39:00 +02:00
Milan Hanajik
d7e6a69ca9 StartMeasurementOp interface changed: OutputPath is the first argment 2015-09-22 17:03:26 +02:00
Milan Hanajik
33963ec8cf Version 1.5.84. Reading registers, scales, temperature, pressure, ... during test done in one state in the sequence.
Many changes in TestMethods.iPerlCommunication and WaterMeters.iPerl.WaterMeter. iPerl measurement with opto-data works OK.
Logging in State changed, ...
2015-08-19 13:04:47 +02:00
Milan Hanajik
f85fbd0b55 Problems when passing flowmeter/diverter info to test start by SendCommand() fixed, version 1.5.77. 2015-08-14 18:14:08 +02:00
Milan Hanajik
0cea24246c Error message due to incorrect configuration is cleared after selecting another procedure/test.
Return value from WaitBeginFormClosed(..) changed from bool to enum UIFlowControl.
2015-06-25 04:48:28 +02:00
Milan Hanajik
edb6d5e8b6 'EndCondiiton' and 'Communication' added to TransitionStep (transition sequence). TODO: EndConditions functionality, version 1.5.44 2015-05-22 11:21:56 +02:00
Milan Hanajik
cd9042a648 PulsesPerLiter added to Entities.MeterTestResult and to result items. Version 1.4.36
More times added to Entities.Test (TimeBeforeFlow, TimeFlow2Mass, TimeMass2Start, TimeStop2Mass).
Activity display fixed in FlyingStartCollectionMethod.
2015-05-19 15:38:58 +02:00
Milan Hanajik
39eb2cfd57 Entry form related improvements / bugfixes (Fixed start collection method related). 2015-04-28 15:27:47 +02:00
Milan Hanajik
be78bb5ce0 Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
Milan Hanajik
1e63ded8e1 MetersKind.Standard in TBF/Entities/Enums.cs reverted to MetersKind.Single 2015-03-25 05:35:05 +01:00
Milan Hanajik
7dce565e4f MetersKind.Single in TBF/Entities/Enuns.cs renamed to MetersKind.Standard 2015-03-25 02:31:28 +01:00
Milan Hanajik
c005a5cb26 Solves issue with an opened CycleBeginForm after abort and re-selection in Israel:
- CloseCycleBeginForm() -> WaitBeginFormClosed()
- CloseBeginForm() added to SequenceBase(forced dialog close)
- CloseModellFormHandler added to UiBridge.Bridge
2015-03-01 11:13:26 +01:00
Milan Hanajik
0c9408ff64 More configuration checks when starting a test 2015-02-02 23:18:28 +01:00
Milan Hanajik
9bd5fba6dc (1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik
e1756f692c Confirmed results to SummaryResults.txt logger 2015-02-02 11:38:42 +01:00
Milan Hanajik
56a9a7cf1b Test results are written into database after confirming with END 2015-02-02 00:08:47 +01:00
Milan Hanajik
ce6214f631 Zapne pumpu pred vypustanim aj pri ostatnych metodach 2015-02-01 19:30:00 +01:00
Milan Hanajik
5cf5fe5eba CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change) 2015-01-25 08:11:40 +01:00
Milan Hanajik
d3532a2796 PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
bb31cdae56 Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results 2015-01-15 06:34:36 +01:00
Milan Hanajik
9c1db2778e Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page 2015-01-15 03:16:14 +01:00
Milan Hanajik
34dc592e59 Timeout while setting the water flow handled correctly: message displayed, test aborted 2015-01-12 05:56:19 +01:00
Milan Hanajik
de90a4638a Prepared: PID coefficient of the output path is ready to be used,
and not the regul.valve parameter. See  // TODO PID: ...  in source code.
 Database: 'PidCoef' float should be added to 'OutputPath' after col.'FlowMeter'
2015-01-03 21:17:11 +01:00
Milan Hanajik
1afd6870c3 Time2MassMsrmt implemented, database tables Test and TestResult changed 2014-12-11 08:49:07 +01:00
Milan Hanajik
930db8c379 - many process tab page improvements
- program start and state changes logging improved
- IDC100 measurement related changes: reference pulses in RegisterReader
- etc
2014-10-02 20:56:24 +02:00
Milan Hanajik
1c34946a6b Bugs in sequences fixed: Missing CheckUiOp 2014-09-26 17:48:55 +02:00
Milan Hanajik
a79be1e07a - bug fixed when component (class) in the DB does not exist in the code
- preparing FixedStartMassCollection sequence
2014-09-16 12:04:08 +02:00
Milan Hanajik
a919a3e9d6 - FLyngStart sequence (without balances) tested -> OK, Todo: use
corrections
- totalPulses calculated correctly in case of I11+I12 (use of two flowmeters)
2014-09-12 07:18:24 +02:00
Milan Hanajik
fcfdfeca41 - COmponent properties 'Position' --> 'Idx0' or 'Idx1'
- process data logging, RegulVal position logging
- changes for I11+I12, NOK yet
2014-09-10 12:05:49 +02:00
Milan Hanajik
d0ebb62ab3 - Component update (temp.)
- Process data logging, first trial
2014-09-09 16:18:23 +02:00
Milan Hanajik
354c13853f All PumpsWithFM are controlled when opening pumps at the test start 2014-09-09 09:14:47 +02:00
Milan Hanajik
6eee83042b PmpWithFM and Transition sequences functionality implemented 2014-09-08 13:16:31 +02:00
Milan Hanajik
b8faca784e - ReferenceFlowmeterCalibration method and sequence (ready for tests)
- FlyingStart method and sequence files prepared for implementation (copies of FlyingStartMassCollection)
2014-09-06 17:34:26 +02:00