Commit Graph

95 Commits

Author SHA1 Message Date
Milan Hanajik
95c05078de Introduction of Program.CompoundWMsCount, fix in DataEntry.Combined.CycleBeginningForm, version 1.5.68. 2015-07-09 16:24:55 +02:00
Milan Hanajik
58f872c6f4 Bug fix in adjustment dialog for 24 watermeters, version 1.5.64. 2015-07-03 02:42:30 +02:00
Milan Hanajik
5292088622 A new form for 24 water meters in adjustment dialog 2015-07-02 17:28:11 +02:00
Milan Hanajik
7b902e8ca3 IComponentFactory.DummyComponent() interface function added and implemented in all components. 2015-06-29 11:14:33 +02:00
Milan Hanajik
0cea24246c Error message due to incorrect configuration is cleared after selecting another procedure/test.
Return value from WaitBeginFormClosed(..) changed from bool to enum UIFlowControl.
2015-06-25 04:48:28 +02:00
Milan Hanajik
c8afb2d87b Added: Fixed start method for combined meters. Version 1.5.55. 2015-06-02 18:04:20 +02:00
Milan Hanajik
1e0e3efd5a TimeFlow2Mass used in CombinedMeters flying start method. Code cleanup. 2015-06-02 17:58:42 +02:00
Milan Hanajik
edb6d5e8b6 'EndCondiiton' and 'Communication' added to TransitionStep (transition sequence). TODO: EndConditions functionality, version 1.5.44 2015-05-22 11:21:56 +02:00
Milan Hanajik
cd9042a648 PulsesPerLiter added to Entities.MeterTestResult and to result items. Version 1.4.36
More times added to Entities.Test (TimeBeforeFlow, TimeFlow2Mass, TimeMass2Start, TimeStop2Mass).
Activity display fixed in FlyingStartCollectionMethod.
2015-05-19 15:38:58 +02:00
Milan Hanajik
e45be1243d MettlerToledo.Multi TaringOp disabled, ver. 1.3.31 2015-05-11 10:36:37 +02:00
Milan Hanajik
f37cb57427 Bug fixes 2015-04-29 19:59:21 +02:00
Milan Hanajik
e124f3f406 DataEntry.Standard: Exclamation mark displayed when entering the end-state and volume is out of limit. 2015-04-29 19:03:00 +02:00
Milan Hanajik
305bbe9c6c TestStartForm and TestEndForm are two separate forms. DataEntry.Standard.TestEndForm shows start states. 2015-04-29 15:33:49 +02:00
Milan Hanajik
8391f22f64 Fixed start method: Delay before the 2nd mass measurement and the diverter switchover, etc. 2015-04-28 19:16:54 +02:00
Milan Hanajik
39eb2cfd57 Entry form related improvements / bugfixes (Fixed start collection method related). 2015-04-28 15:27:47 +02:00
Milan Hanajik
1c81600ae1 Delay time from flow stable and 1st mass measurement added. Database change (Time2MassMsrmt into Test). 2015-04-19 13:07:49 +02:00
Milan Hanajik
be78bb5ce0 Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
Milan Hanajik
274ab79cb7 DataEntry.Standard supports IHasWMStatesForm interface. Fixed start method should work without register readers (test!). 2015-04-14 07:14:45 +02:00
Milan Hanajik
1698a923bf Bug fix in fixed start method error calculation 2015-04-13 21:23:53 +02:00
Milan Hanajik
1e63ded8e1 MetersKind.Standard in TBF/Entities/Enums.cs reverted to MetersKind.Single 2015-03-25 05:35:05 +01:00
Milan Hanajik
23d5e6d19d Disabled watermeters will not appear in results (screen, ResultsPrinters.Basic and ResultsWriters.Basic).
Updating Disabled (default = false) is provided by DataEntry.Standard when entering serial numbers.
2015-03-25 03:57:46 +01:00
Milan Hanajik
7dce565e4f MetersKind.Single in TBF/Entities/Enuns.cs renamed to MetersKind.Standard 2015-03-25 02:31:28 +01:00
Milan Hanajik
f524186b70 More DataEntry.Standard related changes 2015-03-25 02:14:42 +01:00
Milan Hanajik
dc9577eaa0 Test methods for standard watermeter use IWatermeter.Disabled flag to remove non-existing meter results 2015-03-24 10:11:20 +01:00
Milan Hanajik
c005a5cb26 Solves issue with an opened CycleBeginForm after abort and re-selection in Israel:
- CloseCycleBeginForm() -> WaitBeginFormClosed()
- CloseBeginForm() added to SequenceBase(forced dialog close)
- CloseModellFormHandler added to UiBridge.Bridge
2015-03-01 11:13:26 +01:00
Milan Hanajik
82a72670a6 Remaining time displayed for all tests 2015-02-21 20:03:33 +01:00
Milan Hanajik
08e53c090e PMaxTest and LeakTest improvements:
- result items P_xy_start and P_xy_end added
- DurationLeak test parameter for LeakTest method
- correct default parameters for Danfoss.VLT2800.Pump (FC protocol)
- bug fixes
2015-02-20 13:07:21 +01:00
Milan Hanajik
b07c7c5c9d PMaxTest and LeakTest methods implemented, added to the project
Order of two new test wizard dialog exchanged
Pressure Selection wizard dialog added
2015-02-19 15:54:55 +01:00
Milan Hanajik
1dbbe31eae Bug fix for the case of combined WM test and odd total nr. of watermeters (Munich) 2015-02-18 14:49:19 +01:00
Milan Hanajik
0c9408ff64 More configuration checks when starting a test 2015-02-02 23:18:28 +01:00
Milan Hanajik
9bd5fba6dc (1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik
e1756f692c Confirmed results to SummaryResults.txt logger 2015-02-02 11:38:42 +01:00
Milan Hanajik
56a9a7cf1b Test results are written into database after confirming with END 2015-02-02 00:08:47 +01:00
Milan Hanajik
ce6214f631 Zapne pumpu pred vypustanim aj pri ostatnych metodach 2015-02-01 19:30:00 +01:00
Milan Hanajik
57a7510d05 Center stripe in the Error dialog of the Adjustment method 2015-02-01 19:28:26 +01:00
Milan Hanajik
7e8dfd472d Zapne pumpu pred vypustanim 2015-02-01 18:53:09 +01:00
Milan Hanajik
6dbff5978a Pokus 2015-02-01 17:14:50 +01:00
Milan Hanajik
806f4efe6a Results printing and saving uses Publish property of GenericDevices.ITestMethod 2015-02-01 16:20:27 +01:00
Milan Hanajik
efa14c6ebb Adjustment results will not be printed, shown, etc. 2015-02-01 08:20:13 +01:00
Milan Hanajik
0c4da37e85 Adjustment: Graphics added, to be tested 2015-01-28 22:14:30 +01:00
Milan Hanajik
5653628bf7 Adjust: Larger font, place for graphics 2015-01-28 20:57:03 +01:00
Milan Hanajik
94accbf58b Bugfix: Adjustment method modeless dialog was not started in UI thread, freezes 2015-01-28 19:33:02 +01:00
Milan Hanajik
508f47cb6b Adjustment test method ready for tests 2015-01-28 18:18:46 +01:00
Milan Hanajik
85bb34030a Bugfix in Fixed start method when configuration is NOK, no Dummy RR-s
Bugfix in FIxed start method Entry form when config.is NOK, WM-s are missing
2015-01-27 23:00:42 +01:00
Milan Hanajik
5cf5fe5eba CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change) 2015-01-25 08:11:40 +01:00
Milan Hanajik
ad665e5f0b Combined meters measurement corrections, Q_rise and Q_fall in results 2015-01-17 08:57:50 +01:00
Milan Hanajik
d3532a2796 PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
bb31cdae56 Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results 2015-01-15 06:34:36 +01:00
Milan Hanajik
9c1db2778e Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page 2015-01-15 03:16:14 +01:00
Milan Hanajik
1c3c90e171 CombinedMeters and CombinedWithDetection support SupressTrils bool parameter
Warnings 'Unreachable code' supressed in DataEntries
2015-01-14 05:33:51 +01:00