TestMethods.FixedStart.FixedStartSeq code cleanup, references to scale/tank/draining/mass measurement removed.
This commit is contained in:
@@ -31,13 +31,6 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
HeatMeters.TestParams heatMetersTestParams,
|
||||
Config.Entities.DebugMode debugLevel)
|
||||
{
|
||||
IScale scale = outPath.Scale as IScale;
|
||||
if (scale == null)
|
||||
{
|
||||
Bridge.OnError(this, Strings.Missing_a_scale);
|
||||
new List<Event> { Event.ConfigurationError }; /// or Event.UiCmdStop
|
||||
}
|
||||
|
||||
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
||||
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
||||
{
|
||||
@@ -138,61 +131,6 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
}
|
||||
|
||||
|
||||
if (!test.DoDraining)
|
||||
{
|
||||
///
|
||||
/// Measure the weight in case there is no unconditional draining
|
||||
///
|
||||
State.Create(string.Format("{0}({1}) : Measuring mass of water in the tank", test.Method, test.Name))
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperations(readTempPressOps)
|
||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||
.AddOperation(heatMetersPromptOp)
|
||||
.EnterState();
|
||||
do {
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
||||
|
||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
}
|
||||
while (!e.Contains(Event.BalanceDone));
|
||||
}
|
||||
///
|
||||
/// Skip draining in case there is enough room in the tank
|
||||
///
|
||||
if (test.DoDraining || (Mass.Val + test.Volume >= scale.Capacity * Constants.TankFullFactor))
|
||||
{
|
||||
///
|
||||
/// Drain the water tank
|
||||
///
|
||||
switch (DrainTheTank(scale, heatMetersPromptOp))
|
||||
{
|
||||
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
||||
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
}
|
||||
}
|
||||
///
|
||||
/// Make sure the drain valve is closed
|
||||
///
|
||||
State.Create(string.Format("{0}({1}) : Make sure the drain valve is closed", test.Method, test.Name))
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperations(readTempPressOps)
|
||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||
.AddOperation(heatMetersPromptOp)
|
||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
||||
.EnterState();
|
||||
do {
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
||||
|
||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
}
|
||||
while (!e.Contains(Event.ValvesSet) || !e.Contains(Event.BalanceDone));
|
||||
|
||||
|
||||
|
||||
//------------------------------------------------
|
||||
Bridge.OnActivity(this, Strings.Starting_the_pump);
|
||||
//------------------------------------------------
|
||||
@@ -371,12 +309,12 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
{
|
||||
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
|
||||
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
|
||||
if (heatMetersTestParams.TempWarmLo <= Tw && Tw <= heatMetersTestParams.TempWarmHi &&
|
||||
heatMetersTestParams.TempColdLo <= Tc && Tc <= heatMetersTestParams.TempColdHi &&
|
||||
Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm &&
|
||||
Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold &&
|
||||
Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm &&
|
||||
Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold)
|
||||
if ((heatMetersTestParams.TempWarmLo <= Tw) && (Tw <= heatMetersTestParams.TempWarmHi) &&
|
||||
(heatMetersTestParams.TempColdLo <= Tc) && (Tc <= heatMetersTestParams.TempColdHi) &&
|
||||
(Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm) &&
|
||||
(Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold) &&
|
||||
(Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm) &&
|
||||
(Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold))
|
||||
{
|
||||
goto temperature_set;
|
||||
}
|
||||
@@ -434,26 +372,6 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
double currentFlow = RefFlow.Val;
|
||||
|
||||
|
||||
//------------------------------------------------
|
||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||
//------------------------------------------------
|
||||
|
||||
if (test.TimeFlow2Mass > 0)
|
||||
{
|
||||
State.Create(string.Format("{0}({1}) : Waiting before 1st measurement", test.Method, test.Name))
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperations(readTempPressOps)
|
||||
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
||||
.EnterState();
|
||||
do {
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
}
|
||||
while (!e.Contains(Event.TimerExpired));
|
||||
}
|
||||
|
||||
|
||||
TestStartTime = DateTime.Now;
|
||||
LogProcessDataTestInfo(processDataLogger, test.Procedure.Name, test.Name);
|
||||
int startPulses = 0;
|
||||
@@ -486,8 +404,7 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
}
|
||||
}
|
||||
state2.EnterState();
|
||||
do
|
||||
{
|
||||
do {
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
|
||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||
@@ -553,12 +470,19 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
{
|
||||
string srcDir = Path.Combine(Program.TempImagesDir, BatchRslts.Batch.BatchNr.ToString(), (i + 1).ToString());
|
||||
string destDir = Path.Combine(Program.ImagesDir, BatchRslts.Batch.BatchNr.ToString(), (i + 1).ToString());
|
||||
if (File.Exists(Path.Combine(srcDir, fileName)))
|
||||
{
|
||||
Directory.CreateDirectory(destDir);
|
||||
File.Copy(Path.Combine(srcDir, fileName), Path.Combine(destDir, fileName), true);
|
||||
try
|
||||
{
|
||||
if (File.Exists(Path.Combine(srcDir, fileName)))
|
||||
{
|
||||
Directory.CreateDirectory(destDir);
|
||||
File.Copy(Path.Combine(srcDir, fileName), Path.Combine(destDir, fileName), true);
|
||||
}
|
||||
}
|
||||
}
|
||||
catch (Exception exc)
|
||||
{
|
||||
log.ErrorFormat("Failed to copy image {0} to {1}: {2}", fileName, destDir, exc.Message);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -603,7 +527,7 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
queryEnd1 = cBrd.QueryMeasurementEndOp();
|
||||
queryEnd2 = cBrd.QueryMeasurementEndOp();
|
||||
|
||||
StartNewStatistics(StateMachine.Time, BatchRslts.Batch.BatchNr, test.Name, repetitionNr, Math.Max((int)(test.TstTime/10), 5));
|
||||
StartNewStatistics(StateMachine.Time, BatchRslts.Batch.BatchNr, test.Name, repetitionNr, Math.Max((int)(test.TstTime / 10), 5));
|
||||
int estimtdEndTime = StateMachine.Time + (int)test.TstTime;
|
||||
|
||||
/// Measurement loop - begin
|
||||
@@ -696,22 +620,22 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
}
|
||||
while (e.Contains(Event.ValvesBusy));
|
||||
|
||||
switchTimeEnd = 0.001f * cBrd.ValveOpenCloseTime;
|
||||
log.WarnFormat("Start valve switch time on test end = {0} ms", cBrd.ValveOpenCloseTime);
|
||||
|
||||
State.Create(string.Format("{0}({1}) : Waiting before 2nd measurement", test.Method, test.Name))
|
||||
State.Create(string.Format("{0}({1}) : Stopping flow regulation", test.Method, test.Name))
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperations(readTempPressOps)
|
||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||
.AddOperation(processDataLoggingOp)
|
||||
.AddOperation(cBrd.StopFlowRegulationOp(outPath))
|
||||
.EnterState();
|
||||
do {
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
}
|
||||
while (!e.Contains(Event.TimerExpired));
|
||||
while (!e.Contains(Event.FlowRegulationStopped));
|
||||
|
||||
|
||||
switchTimeEnd = 0.001f * cBrd.ValveOpenCloseTime;
|
||||
log.WarnFormat("Start valve switch time on test end = {0} ms", cBrd.ValveOpenCloseTime);
|
||||
|
||||
|
||||
TestEndTime = DateTime.Now;
|
||||
@@ -780,7 +704,8 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
State state = State.Create(string.Format("{0}({1}) : Entering the end-state", test.Method, test.Name));
|
||||
if (heatMetersTestParams != null && dataEntryCmpnt is GenericDevices.IHasHeatMtrStatesForm)
|
||||
{
|
||||
state.AddOperation((dataEntryCmpnt as GenericDevices.IHasHeatMtrStatesForm).ShowTestEndFormOp(sensPath.RegisterReaders,
|
||||
state.AddOperation((dataEntryCmpnt as GenericDevices.IHasHeatMtrStatesForm).
|
||||
ShowTestEndFormOp(sensPath.RegisterReaders,
|
||||
volumeCTV, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty,
|
||||
refEnergy, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty));
|
||||
}
|
||||
@@ -840,11 +765,18 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
{
|
||||
string srcDir = Path.Combine(Program.TempImagesDir, BatchRslts.Batch.BatchNr.ToString(), (i + 1).ToString());
|
||||
string destDir = Path.Combine(Program.ImagesDir, BatchRslts.Batch.BatchNr.ToString(), (i + 1).ToString());
|
||||
if (File.Exists(Path.Combine(srcDir, fileName)))
|
||||
{
|
||||
Directory.CreateDirectory(destDir);
|
||||
File.Copy(Path.Combine(srcDir, fileName), Path.Combine(destDir, fileName), true);
|
||||
}
|
||||
try
|
||||
{
|
||||
if (File.Exists(Path.Combine(srcDir, fileName)))
|
||||
{
|
||||
Directory.CreateDirectory(destDir);
|
||||
File.Copy(Path.Combine(srcDir, fileName), Path.Combine(destDir, fileName), true);
|
||||
}
|
||||
}
|
||||
catch (Exception exc)
|
||||
{
|
||||
log.ErrorFormat("Failed to copy image {0} to {1}: {2}", fileName, destDir, exc.Message);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -1060,7 +992,7 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
(BenchInfo != null) ? BenchInfo.TestBenchName : "testbench",
|
||||
inPath.Pump != null ? inPath.Pump.Name : string.Empty,
|
||||
outPath.FlowMeter != null ? outPath.FlowMeter.Name : string.Empty,
|
||||
scale != null ? scale.Name : string.Empty,
|
||||
string.Empty,
|
||||
outPath.RegulValve != null ? outPath.RegulValve.Name : string.Empty,
|
||||
outPath.Diverter != null ? outPath.Diverter.Name : string.Empty));
|
||||
|
||||
|
||||
+3
-4
@@ -80,7 +80,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
||||
foreach (var rr in sensPath.RegisterReaders)
|
||||
{
|
||||
TBF.BenchControl.Elde.RegisterReader.RegisterReader eldeRR = rr as TBF.BenchControl.Elde.RegisterReader.RegisterReader;
|
||||
if (eldeRR != null && eldeRR.Position >= 1 && eldeRR.Position <= 8)
|
||||
if ((eldeRR != null) && (eldeRR.Position >= 1) && (eldeRR.Position <= 8))
|
||||
{
|
||||
filters[eldeRR.Position - 1] = eldeRR.Filter;
|
||||
}
|
||||
@@ -618,7 +618,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperations(readTempPressOps)
|
||||
.AddOperation(cBrd.StartMeasurementOp(outPath, (Elde.TestMethods.Diverter | Elde.TestMethods.FixedStart),
|
||||
test.Qfrom, test.Qto, (2 * totalPulses)))
|
||||
test.Qfrom, test.Qto, 2 * totalPulses))
|
||||
.EnterState();
|
||||
do {
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
@@ -868,8 +868,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
||||
}
|
||||
}
|
||||
state2.EnterState();
|
||||
do
|
||||
{
|
||||
do {
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
|
||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||
|
||||
Reference in New Issue