Sequence before test modification: Test paths (input, bench, output) are applied after the last step.

This commit is contained in:
Milan Hanajik
2016-03-15 16:06:44 +08:00
parent b879245df2
commit 1fb82dad92
@@ -223,24 +223,7 @@ namespace TBF.BenchControl.Sequences
///
/// No transition sequence defined --> Default action
///
if (context == TransitionContext.BeforeTest)
{
State.Create("SequenceBase : Transition : TestStart - Default action")
.AddOperation(checkUiOp)
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(StateMachine.ControlBoard
.SetValvesOp(GenericDevices.ValveBase.Merge(inPath.ValvesOpen, benchPath.ValvesOpen, outPath.ValvesOpen),
GenericDevices.ValveBase.Merge(inPath.ValvesClose, benchPath.ValvesClose, outPath.ValvesClose)))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.UiCmdStop)) return Event.UiCmdStop;
}
while (e.Contains(Event.ValvesBusy));
}
else if (context == TransitionContext.AfterTest)
if (context == TransitionContext.AfterTest)
{
State.Create("SequenceBase : Transition : TestEnd - Default action")
.AddOperation(checkUiOp)
@@ -249,7 +232,8 @@ namespace TBF.BenchControl.Sequences
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen,
StateMachine.DefaultValvesClose))
.EnterState();
do {
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.UiCmdStop)) return Event.UiCmdStop;
}
@@ -417,15 +401,20 @@ namespace TBF.BenchControl.Sequences
Bridge.OnMessage(this, string.Empty); /// Clear the last step message
}
///
/// Do this after executing the transition sequence
///
if (context == TransitionContext.Stop || errorFlag || stopFlag)
{
///
/// Stop the pump at the end of test
/// On error or when STOP pressed
///
foreach (var fmPump in PumpsWithFM) fmPump.TurnOff();
if (inPath != null)
{
/// Stop the pump
///
State.Create("SequenceBase.Transition() : Test stopped -> Stopping the pump")
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
@@ -440,6 +429,28 @@ namespace TBF.BenchControl.Sequences
while (!e.Contains(Event.ValvesSet) || ((inPath.Pump is GenericDevices.IPumpFM) && !e.Contains(Event.TurnPumpOnOffDone)));
}
}
else if (context == TransitionContext.BeforeTest)
{
if (inPath != null && benchPath != null && outPath != null)
{
State.Create("SequenceBase : Transition : TestStart - Default action")
.AddOperation(checkUiOp)
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(StateMachine.ControlBoard
.SetValvesOp(GenericDevices.ValveBase.Merge(inPath.ValvesOpen, benchPath.ValvesOpen, outPath.ValvesOpen),
GenericDevices.ValveBase.Merge(inPath.ValvesClose, benchPath.ValvesClose, outPath.ValvesClose)))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) return Event.Error;
if (e.Contains(Event.UiCmdStop)) return Event.UiCmdStop;
}
while (e.Contains(Event.ValvesBusy));
}
}
if (errorFlag)
return Event.Error;