Sequence before test modification: Test paths (input, bench, output) are applied after the last step.
This commit is contained in:
@@ -223,24 +223,7 @@ namespace TBF.BenchControl.Sequences
|
||||
///
|
||||
/// No transition sequence defined --> Default action
|
||||
///
|
||||
if (context == TransitionContext.BeforeTest)
|
||||
{
|
||||
State.Create("SequenceBase : Transition : TestStart - Default action")
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
|
||||
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
|
||||
.AddOperation(StateMachine.ControlBoard
|
||||
.SetValvesOp(GenericDevices.ValveBase.Merge(inPath.ValvesOpen, benchPath.ValvesOpen, outPath.ValvesOpen),
|
||||
GenericDevices.ValveBase.Merge(inPath.ValvesClose, benchPath.ValvesClose, outPath.ValvesClose)))
|
||||
.EnterState();
|
||||
do
|
||||
{
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
if (e.Contains(Event.UiCmdStop)) return Event.UiCmdStop;
|
||||
}
|
||||
while (e.Contains(Event.ValvesBusy));
|
||||
}
|
||||
else if (context == TransitionContext.AfterTest)
|
||||
if (context == TransitionContext.AfterTest)
|
||||
{
|
||||
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
||||
.AddOperation(checkUiOp)
|
||||
@@ -249,7 +232,8 @@ namespace TBF.BenchControl.Sequences
|
||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen,
|
||||
StateMachine.DefaultValvesClose))
|
||||
.EnterState();
|
||||
do {
|
||||
do
|
||||
{
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
if (e.Contains(Event.UiCmdStop)) return Event.UiCmdStop;
|
||||
}
|
||||
@@ -417,15 +401,20 @@ namespace TBF.BenchControl.Sequences
|
||||
Bridge.OnMessage(this, string.Empty); /// Clear the last step message
|
||||
}
|
||||
|
||||
///
|
||||
/// Do this after executing the transition sequence
|
||||
///
|
||||
if (context == TransitionContext.Stop || errorFlag || stopFlag)
|
||||
{
|
||||
///
|
||||
/// Stop the pump at the end of test
|
||||
/// On error or when STOP pressed
|
||||
///
|
||||
foreach (var fmPump in PumpsWithFM) fmPump.TurnOff();
|
||||
|
||||
if (inPath != null)
|
||||
{
|
||||
/// Stop the pump
|
||||
///
|
||||
State.Create("SequenceBase.Transition() : Test stopped -> Stopping the pump")
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
|
||||
@@ -440,6 +429,28 @@ namespace TBF.BenchControl.Sequences
|
||||
while (!e.Contains(Event.ValvesSet) || ((inPath.Pump is GenericDevices.IPumpFM) && !e.Contains(Event.TurnPumpOnOffDone)));
|
||||
}
|
||||
}
|
||||
else if (context == TransitionContext.BeforeTest)
|
||||
{
|
||||
if (inPath != null && benchPath != null && outPath != null)
|
||||
{
|
||||
State.Create("SequenceBase : Transition : TestStart - Default action")
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
|
||||
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
|
||||
.AddOperation(StateMachine.ControlBoard
|
||||
.SetValvesOp(GenericDevices.ValveBase.Merge(inPath.ValvesOpen, benchPath.ValvesOpen, outPath.ValvesOpen),
|
||||
GenericDevices.ValveBase.Merge(inPath.ValvesClose, benchPath.ValvesClose, outPath.ValvesClose)))
|
||||
.EnterState();
|
||||
do
|
||||
{
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
if (e.Contains(Event.Error)) return Event.Error;
|
||||
if (e.Contains(Event.UiCmdStop)) return Event.UiCmdStop;
|
||||
}
|
||||
while (e.Contains(Event.ValvesBusy));
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
if (errorFlag)
|
||||
return Event.Error;
|
||||
|
||||
Reference in New Issue