add revers mesuremnt to magflux
This commit is contained in:
@@ -168,7 +168,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// <summary>
|
||||
/// the first measurement is ALWAYS a FlowTestRecord due to the underlying<see cref="GetAllMeasurementResults"/> routine logic.
|
||||
/// </summary>
|
||||
public MeasurementResults GetMainMeasurementResult(Double? refVolume, Double? refTimeS, Boolean intermediateMeasurement = false)
|
||||
public MeasurementResults GetMainMeasurementResult(Double? refVolume, Double? refTimeS, Boolean intermediateMeasurement = false, MeasurementDirection dir = MeasurementDirection.TakeBoth)
|
||||
{
|
||||
if (!intermediateMeasurement && GetMeasurementState(0) != MeasurementStates.IsCompleted)
|
||||
{
|
||||
@@ -180,19 +180,20 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// <summary>
|
||||
/// The first measurement is ALWAYS a FlowTestRecord.
|
||||
/// </summary>
|
||||
public List<MeasurementResults> GetAllMeasurementResults(Double? refVolume, Double? refTimeS, Boolean intermediateMeasurement = false, Int32? channel = null)
|
||||
public List<MeasurementResults> GetAllMeasurementResults(Double? refVolume, Double? refTimeS, Boolean intermediateMeasurement = false, Int32? channel = null, MeasurementDirection dir = MeasurementDirection.TakeBoth)
|
||||
{
|
||||
//
|
||||
if (!intermediateMeasurement && GetMeasurementState(channel) != MeasurementStates.IsCompleted)
|
||||
{
|
||||
throw new ApplicationException("Measurement is not completed");
|
||||
}
|
||||
var mainMeasurement = _listOfIMeasurement.FirstOrDefault(m => m.GetType() == typeof(FlowTestRecord));
|
||||
|
||||
|
||||
if (mainMeasurement == null)
|
||||
{
|
||||
throw new ApplicationException("Can not find an ongoing measurement");
|
||||
}
|
||||
|
||||
mainMeasurement.FlowDirectionforCalculatingVol = dir;
|
||||
var results = new List<MeasurementResults>();
|
||||
var mainResult = intermediateMeasurement
|
||||
? mainMeasurement.GetIntermediateMeasurementResult(refVolume, refTimeS)
|
||||
|
||||
@@ -864,18 +864,19 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
|
||||
/// <inheritdoc />
|
||||
public MeasurementResults GetMainMeasurementResult(Double? refVolume, Double? refTimeS,
|
||||
Boolean intermediateMeasurement = false)
|
||||
Boolean intermediateMeasurement = false, MeasurementDirection dir = MeasurementDirection.TakeBoth)
|
||||
{
|
||||
if (!intermediateMeasurement && GetMeasurementState(0) != MeasurementStates.IsCompleted)
|
||||
{
|
||||
throw new ApplicationException("Measurement is not completed");
|
||||
}
|
||||
return GetAllMeasurementResults(refVolume, refTimeS, intermediateMeasurement, 0).First();
|
||||
return GetAllMeasurementResults(refVolume, refTimeS, intermediateMeasurement, 0,dir).First();
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
///
|
||||
public List<MeasurementResults> GetAllMeasurementResults(Double? refVolume, Double? refTimeS, Boolean intermediateMeasurement = false,
|
||||
Int32? channel = null)
|
||||
Int32? channel = null, MeasurementDirection dir = MeasurementDirection.TakeBoth)
|
||||
{
|
||||
if (!intermediateMeasurement && GetMeasurementState(channel) != MeasurementStates.IsCompleted)
|
||||
{
|
||||
|
||||
@@ -169,14 +169,14 @@ namespace Xylem.Common.Hardware.WaterMeter.WaterMeterCore
|
||||
/// After a completed measurement , you can grab <see cref="MeasurementResults"/>
|
||||
/// </summary>
|
||||
/// <returns>Calculated results</returns>
|
||||
MeasurementResults GetMainMeasurementResult(Double? refVolume, Double? refTimeS, Boolean intermediateMeasurement = false);
|
||||
MeasurementResults GetMainMeasurementResult(Double? refVolume, Double? refTimeS, Boolean intermediateMeasurement = false, MeasurementDirection dir = MeasurementDirection.TakeBoth);
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// The first measurement is ALWAYS a FlowTestRecord.
|
||||
/// </summary>
|
||||
List<MeasurementResults> GetAllMeasurementResults(Double? refVolume, Double? refTimeS,
|
||||
Boolean intermediateMeasurement = false, Int32? channel = null);
|
||||
Boolean intermediateMeasurement = false, Int32? channel = null, MeasurementDirection dir = MeasurementDirection.TakeBoth);
|
||||
|
||||
|
||||
|
||||
@@ -283,5 +283,6 @@ namespace Xylem.Common.Hardware.WaterMeter.WaterMeterCore
|
||||
/// Clear all object set up on runtime
|
||||
/// </summary>
|
||||
void DisposeMeter();
|
||||
|
||||
}
|
||||
}
|
||||
+1
-1
@@ -1 +1 @@
|
||||
1a3d4919c9c702245832d925951f2b7cb72fc333
|
||||
5ed75d99ee45ff67821090f1b3dbb001dd9e4fe3
|
||||
|
||||
@@ -42,6 +42,9 @@ namespace Xylem.Common.Metrology.Measurements
|
||||
/// </summary>
|
||||
public IMeasurementRecord IntermediateRecord;
|
||||
|
||||
|
||||
|
||||
|
||||
/// <inheritdoc />
|
||||
public event EventHandler OnActionStateHasChanged;
|
||||
|
||||
@@ -116,6 +119,10 @@ namespace Xylem.Common.Metrology.Measurements
|
||||
}
|
||||
}
|
||||
|
||||
public MeasurementDirection FlowDirectionforCalculatingVol { get; set; } = MeasurementDirection.TakeBoth;
|
||||
|
||||
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
@@ -216,7 +223,7 @@ namespace Xylem.Common.Metrology.Measurements
|
||||
throw new ApplicationException("Measurement records missing");
|
||||
|
||||
return new MeasurementResults(DutStartRecord, DutStopRecord, _accuDutOverflowVolumeCm,
|
||||
_accuDutOverflowTimeS, refVolumeCm, refTimeS, _channel);
|
||||
_accuDutOverflowTimeS, refVolumeCm, refTimeS, _channel, FlowDirectionforCalculatingVol);
|
||||
}
|
||||
|
||||
private void CheckForOverFlowVolumeAndTime()
|
||||
|
||||
@@ -0,0 +1,12 @@
|
||||
namespace Xylem.Common.Metrology.Measurements.Consts
|
||||
{
|
||||
public enum MeasurementDirection
|
||||
{
|
||||
|
||||
TakeBoth,
|
||||
TakeOnlyForward,
|
||||
TakeOnlyBackward,
|
||||
|
||||
}
|
||||
|
||||
}
|
||||
@@ -31,6 +31,12 @@ namespace Xylem.Common.Metrology.Measurements
|
||||
/// </summary>
|
||||
MeasurementStates MeasurementState { get; set; }
|
||||
|
||||
/// <summary>
|
||||
/// Actual state of the measurement
|
||||
/// </summary>
|
||||
MeasurementDirection FlowDirectionforCalculatingVol { get; set; }
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Clear start, intermediate and end record and set action state to idle
|
||||
/// </summary>
|
||||
|
||||
@@ -14,7 +14,13 @@ namespace Xylem.Common.Metrology.Measurements
|
||||
/// Get volume of the record
|
||||
/// </summary>
|
||||
Double GetVolumeCm();
|
||||
|
||||
|
||||
|
||||
|
||||
Double GetNegativeReserveVolumeCm();
|
||||
|
||||
Double GetForwardVolumeCm();
|
||||
|
||||
/// <summary>
|
||||
/// Get time stamp of the record from meter
|
||||
/// </summary>
|
||||
|
||||
@@ -116,5 +116,17 @@ namespace Xylem.Common.Metrology.Measurements
|
||||
{
|
||||
return MemberwiseClone();
|
||||
}
|
||||
|
||||
public Double GetNegativeReserveVolumeCm()
|
||||
{
|
||||
return NegativeReverseVolumeCm;
|
||||
|
||||
|
||||
}
|
||||
|
||||
public Double GetForwardVolumeCm()
|
||||
{
|
||||
return ForwardVolumeCm;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -8,6 +8,7 @@ namespace Xylem.Common.Metrology.Measurements
|
||||
/// </summary>
|
||||
public struct MeasurementResults
|
||||
{
|
||||
|
||||
/// <inheritdoc cref="MeasurementResultsStates"/>
|
||||
public readonly MeasurementResultsStates State;
|
||||
|
||||
@@ -157,7 +158,7 @@ namespace Xylem.Common.Metrology.Measurements
|
||||
/// <param name="requiredChannel">physical channel of measurement path (0 for main measurement)</param>
|
||||
public MeasurementResults(IMeasurementRecord dutStartRecord, IMeasurementRecord dutStopRecord,
|
||||
Double accuDutOverflowVolumeCm = 0.0, Double accuDutOverflowTimeS = 0.0, Double? refVolumeCm = null,
|
||||
Double? refTimeS = null, Int32 requiredChannel = 0)
|
||||
Double? refTimeS = null, Int32 requiredChannel = 0, MeasurementDirection takeDirections = MeasurementDirection.TakeBoth)
|
||||
{
|
||||
//backup input
|
||||
DutStartRecord = dutStartRecord;
|
||||
@@ -185,9 +186,26 @@ namespace Xylem.Common.Metrology.Measurements
|
||||
State = MeasurementResultsStates.WrongChannel;
|
||||
return;
|
||||
}
|
||||
|
||||
//build the measured volume
|
||||
DutVolumeCm = (DutStopRecord.GetVolumeCm() + accuDutOverflowVolumeCm) - DutStartRecord.GetVolumeCm();
|
||||
switch (takeDirections)
|
||||
{
|
||||
case MeasurementDirection.TakeBoth:
|
||||
//build the measured volume
|
||||
DutVolumeCm = (DutStopRecord.GetVolumeCm() + accuDutOverflowVolumeCm) - DutStartRecord.GetVolumeCm();
|
||||
break;
|
||||
case MeasurementDirection.TakeOnlyForward:
|
||||
//build the measured volume
|
||||
DutVolumeCm = (DutStopRecord.GetForwardVolumeCm() + accuDutOverflowVolumeCm) - DutStartRecord.GetForwardVolumeCm();
|
||||
break;
|
||||
case MeasurementDirection.TakeOnlyBackward:
|
||||
//build the measured volume
|
||||
DutVolumeCm = (DutStopRecord.GetNegativeReserveVolumeCm() + accuDutOverflowVolumeCm) - DutStartRecord.GetNegativeReserveVolumeCm();
|
||||
break;
|
||||
default:
|
||||
//build the measured volume
|
||||
DutVolumeCm = (DutStopRecord.GetVolumeCm() + accuDutOverflowVolumeCm) - DutStartRecord.GetVolumeCm();
|
||||
break;
|
||||
}
|
||||
|
||||
//assume a correct measurement for static start/stop procedure, in case of flying start/stop
|
||||
//this is going to be overwritten if REF time is set
|
||||
CorrectedDutVolumeCm = DutVolumeCm;
|
||||
|
||||
@@ -176,6 +176,7 @@
|
||||
</Compile>
|
||||
<Compile Include="BaseMeasurement.cs" />
|
||||
<Compile Include="CalibrationMeasurement.cs" />
|
||||
<Compile Include="Consts\MeasurementDirection.cs" />
|
||||
<Compile Include="Consts\MeasurementResultsStates.cs" />
|
||||
<Compile Include="Consts\MeasurementStates.cs" />
|
||||
<Compile Include="Consts\ProcessStates.cs" />
|
||||
|
||||
+3
@@ -282,6 +282,9 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
|
||||
funkadresse.AddRange((new Byte[] { 0xAC, 0x21, 0x65, 0x35 }).ToArray());
|
||||
overAllResult.Add(_currentGenesis_WriteRegister("SENSUSRADIO_EncryptionKey", funkadresse.ToArray(), true, true));
|
||||
|
||||
|
||||
|
||||
|
||||
overAllResult.Add(_currentGenesis_WriteRegister("SENSUSRADIO_RadioAddress", radioParams.RadioAddress, true, true));
|
||||
|
||||
if (radioParams.PowerLevel > 0 && radioParams.PowerLevelOption > 0 && radioParams.ImpedanceCodeNew > 0 && radioParams.ImpedanceCodeOption > 0)
|
||||
|
||||
+1
-1
@@ -1 +1 @@
|
||||
f64d563def603c89cafafa61a3219ba97e1e344c
|
||||
0d85a5b3a7561b41163c20e5dc7713bcd0d65555
|
||||
|
||||
@@ -16,6 +16,8 @@ namespace XylemCommonUiLegacyGenCtl.DataPackage
|
||||
public decimal FlowAdjustmentTarget { get; set; }
|
||||
public bool PreAdjustment { get; set; }
|
||||
public bool FlowTesting { get; set; }
|
||||
public Boolean FlowTestingOnlyForward { get; internal set; }
|
||||
public Boolean FlowTestingOnlyRevers { get; internal set; }
|
||||
}
|
||||
|
||||
public class MeterTestResults
|
||||
|
||||
@@ -51,6 +51,8 @@ namespace XylemCommonUiLegacyGenCtl.DataPackage
|
||||
sb.AppendLine($"FlowAdjustment={item.FlowAdjustment}");
|
||||
sb.AppendLine($"FlowAdjustmentTarget={item.FlowAdjustmentTarget}");
|
||||
sb.AppendLine($"meterType={item.meterType}");
|
||||
sb.AppendLine($"FlowTestingOnlyForward={item.FlowTestingOnlyForward}");
|
||||
sb.AppendLine($"FlowTestingOnlyRevers={item.FlowTestingOnlyRevers}");
|
||||
}
|
||||
|
||||
|
||||
|
||||
@@ -182,11 +182,13 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
/// <param name="doubleRefTime">Time in S how long the messuremnt on the ref was running</param>
|
||||
/// <returns></returns>
|
||||
Results GetResults(int Slot, int Chnnl, double refVol, double doubleRefTime);
|
||||
|
||||
/// <summary>
|
||||
/// write a log entry from the caller (test bench) to the current meters log file
|
||||
/// </summary>
|
||||
/// <param name="slot">Slot for identify the meter</param>
|
||||
/// <param name="message"></param>
|
||||
///
|
||||
void LogMeter(int slot, string message);
|
||||
|
||||
/// <summary>
|
||||
|
||||
@@ -38,7 +38,7 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
|
||||
|
||||
|
||||
void SetMeterTestSettings(int Slot, string SerialNr, bool FlowAdjustment, double FlowAdjustmentTarget, bool PreAdjustment, bool FlowTesting);
|
||||
void SetMeterTestSettings(int Slot, string SerialNr, bool FlowAdjustment, double FlowAdjustmentTarget, bool PreAdjustment, bool FlowTesting, bool MagFlux, bool Cordonel, bool ReversFlow);
|
||||
string GetMeterSerialNr(int Slot);
|
||||
bool GetFlowAdjustment(int Slot);
|
||||
bool GetPreAdjustment(int Slot);
|
||||
|
||||
@@ -174,10 +174,11 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
|
||||
|
||||
|
||||
|
||||
#region MeterStuff
|
||||
|
||||
|
||||
public void SetMeterTestSettings(int Slot, string SerialNr, bool FlowAdjustment, double FlowAdjustmentTarget, bool PreAdjustment, bool FlowTesting)
|
||||
public void SetMeterTestSettings(int Slot, string SerialNr, bool FlowAdjustment, double FlowAdjustmentTarget, bool PreAdjustment, bool FlowTesting, bool MagFlux, bool Cordonel,bool ReversFlow)
|
||||
{
|
||||
HanldWrongInputMeters(Slot);
|
||||
|
||||
@@ -199,7 +200,26 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
testSetup.meterTestSettings[Slot - 1].FlowAdjustmentTarget = Convert.ToDecimal(FlowAdjustmentTarget);
|
||||
testSetup.meterTestSettings[Slot - 1].PreAdjustment = PreAdjustment;
|
||||
testSetup.meterTestSettings[Slot - 1].FlowTesting = FlowTesting;
|
||||
testSetup.meterTestSettings[Slot - 1].meterType = Xylem.Common.Hardware.WaterMeter.WaterMeterCore.MeterTypes.MagFlux;
|
||||
if (MagFlux)
|
||||
{
|
||||
testSetup.meterTestSettings[Slot - 1].meterType = Xylem.Common.Hardware.WaterMeter.WaterMeterCore.MeterTypes.MagFlux;
|
||||
}
|
||||
if (Cordonel)
|
||||
{
|
||||
testSetup.meterTestSettings[Slot - 1].meterType = Xylem.Common.Hardware.WaterMeter.WaterMeterCore.MeterTypes.Cordonel;
|
||||
}
|
||||
testSetup.meterTestSettings[Slot - 1].FlowTestingOnlyForward = true;
|
||||
testSetup.meterTestSettings[Slot - 1].FlowTestingOnlyRevers = false;
|
||||
|
||||
if (ReversFlow)
|
||||
{
|
||||
testSetup.meterTestSettings[Slot - 1].FlowTestingOnlyForward = false;
|
||||
testSetup.meterTestSettings[Slot - 1].FlowTestingOnlyRevers = true;
|
||||
}
|
||||
|
||||
|
||||
|
||||
|
||||
}
|
||||
|
||||
|
||||
|
||||
@@ -884,7 +884,6 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
{
|
||||
if (TestSetupContainer == null)
|
||||
{
|
||||
MessageBox.Show("TestSetupContainer is null so add a new one");
|
||||
TestSetupContainer = new TestSetupContainer();
|
||||
TestSetupContainer.AllChanelsRequired = true;
|
||||
TestSetupContainer.meterTestSettings = new MeterTestSettings[10];
|
||||
@@ -893,7 +892,6 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
|
||||
if (!TestSetupContainer.meterTestSettings.Any(f => f != null && f.Slot == slot))
|
||||
{
|
||||
MessageBox.Show($"TestSetupContainer has no entrys for Slot {slot}");
|
||||
TestSetupContainer.meterTestSettings[slot] = new MeterTestSettings() { SerialNr = serialNumber, Slot = slot, FlowAdjustment = true, FlowTesting = true };
|
||||
TestSetupContainer.meterTestResults[slot] = new MeterTestResults() { SerialNr = serialNumber, Slot = slot, meterType = MeterTypes.MagFlux, Results = new List<Xylem.Common.Hardware.WaterMeter.DataPackages.MeasurementRecords.FlowDeviations>() };
|
||||
|
||||
@@ -1021,7 +1019,7 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
sb.AppendLine($"Results: {result.SerialNr} on ep. {result.Slot}");
|
||||
foreach (var flowDeviations in result.Results)
|
||||
{
|
||||
MessageBox.Show($"RefFlow {flowDeviations.MeasuredRefFlowQmPerH} (for {flowDeviations.RefTimeS} Seconds) vs DutFlow {flowDeviations.MeasuredDutFlowQmPerH} (for {flowDeviations.DutTimeS} Seconds)");
|
||||
//MessageBox.Show($"RefFlow {flowDeviations.MeasuredRefFlowQmPerH} (for {flowDeviations.RefTimeS} Seconds) vs DutFlow {flowDeviations.MeasuredDutFlowQmPerH} (for {flowDeviations.DutTimeS} Seconds)");
|
||||
sb.AppendLine($"RefFlow {flowDeviations.MeasuredRefFlowQmPerH} (for {flowDeviations.RefTimeS} Seconds) vs DutFlow {flowDeviations.MeasuredDutFlowQmPerH} (for {flowDeviations.DutTimeS} Seconds)");
|
||||
}
|
||||
//MessageBox.Show(sb.ToString());
|
||||
@@ -1516,7 +1514,7 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
}
|
||||
|
||||
|
||||
private MeasurementResults? GetMeasurementResult(Int32 Slot, Int32 Chnnl, Double refVolQm, Double refTimeS)
|
||||
private MeasurementResults? GetMeasurementResult(Int32 Slot, Int32 Chnnl, Double refVolQm, Double refTimeS, MeasurementDirection dir = MeasurementDirection.TakeBoth)
|
||||
{
|
||||
try
|
||||
{
|
||||
@@ -1543,7 +1541,7 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
}
|
||||
}
|
||||
|
||||
result = refTimeS == 0.0 ? meter.GetMainMeasurementResult(refVolQm, null) : meter.GetMainMeasurementResult(refVolQm, refTimeS);
|
||||
result = refTimeS == 0.0 ? meter.GetMainMeasurementResult(refVolQm, null, dir: dir) : meter.GetMainMeasurementResult(refVolQm, refTimeS, dir: dir);
|
||||
return result;
|
||||
}
|
||||
catch (Exception ex)
|
||||
@@ -1559,7 +1557,26 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
try
|
||||
{
|
||||
//todo remove
|
||||
var result = GetMeasurementResult(Slot, Chnnl, refVolQm, refTimeS);
|
||||
MeasurementResults? result;
|
||||
var t = MeasurementDirection.TakeBoth;
|
||||
|
||||
|
||||
|
||||
if (TestSetupContainer != null && TestSetupContainer.meterTestSettings != null && TestSetupContainer.meterTestSettings.Any(ts => ts.Slot == Slot))
|
||||
{
|
||||
|
||||
var testset = TestSetupContainer.meterTestSettings.First(ts => ts.Slot == Slot);
|
||||
if (testset.FlowTestingOnlyRevers)
|
||||
{
|
||||
t = MeasurementDirection.TakeOnlyBackward;
|
||||
}
|
||||
else if (testset.FlowTestingOnlyForward)
|
||||
{
|
||||
t = MeasurementDirection.TakeOnlyForward;
|
||||
}
|
||||
}
|
||||
result = GetMeasurementResult(Slot, Chnnl, refVolQm, refTimeS,t);
|
||||
|
||||
if (!result.HasValue)
|
||||
{
|
||||
_logger.Warn($"No Result found for GetResults(Slot={Slot},Chnnl={Chnnl},refVolQm={refVolQm},refTimeS={refTimeS})");
|
||||
@@ -1595,14 +1612,14 @@ namespace XylemCommonUiLegacyGenCtl
|
||||
|
||||
if (TestSetupContainer.meterTestResults == null)
|
||||
{
|
||||
MessageBox.Show("meterTestResults emtpty on getresults");
|
||||
// MessageBox.Show("meterTestResults emtpty on getresults");
|
||||
var countMeters = TestSetupContainer.meterTestSettings?.Count() ?? 10;
|
||||
|
||||
TestSetupContainer.meterTestResults = new MeterTestResults[countMeters];
|
||||
}
|
||||
if (!TestSetupContainer.meterTestResults.Any(f => f != null && f.Slot == Slot))
|
||||
{
|
||||
MessageBox.Show("meterTestResults not found on getresults");
|
||||
// MessageBox.Show("meterTestResults not found on getresults");
|
||||
TestSetupContainer.meterTestResults[Slot - 1].Results = new List<Xylem.Common.Hardware.WaterMeter.DataPackages.MeasurementRecords.FlowDeviations>();
|
||||
}
|
||||
|
||||
|
||||