battery limits & productionData

This commit is contained in:
Stoyan Zlatev
2025-02-14 10:27:05 +01:00
parent 29f92330e3
commit f141ea823c
7 changed files with 229 additions and 128 deletions
Binary file not shown.
@@ -320,10 +320,7 @@
ON cluster.FileId = filemap.FileMapToCluster_FileClusterId
LEFT JOIN [File] AS __files
ON filemap.FileMapToCluster_FileId = __files.FileId
WHERE fw.Metersize = @meterSize
AND fw.RadioFrequencyMhz = @frequency
AND fw.CurrentForProd = 1
AND fw.IsReleased = 1)
WHERE fw.Name = @fwVersion)
AS _files)
AS files
ON apps.AppId = files.FilesAppId
@@ -404,67 +401,67 @@
/// Contains placeholder for the pcbId variable name at positon: 0
/// </summary>
private const string RSSI_SETUP_DEFAULTS_RESULTS_BY_PCB = @"
SELECT DISTINCT TOP 1
settings.RadioAddress
, settings.Frequency
, settings.Nennweite
, settings.Baulaenge
, settings.PulseModule
, settings.DruckSensor
, rssiLimits.id AS LimitId
, rssiLimits.RSSI_PAM_Min
, rssiLimits.RSSI_PAM_Max
, rssiLimits.RSSI_SEMI_Min
, rssiLimits.RSSI_SEMI_Max
, rssiHistory.id AS RadioId
, rssiHistory.LimitId AS RadioLimitId
, rssiHistory.RSSI_PAM
, rssiHistory.RSSI_SEMI
, rssiHistory.Datum
SELECT settings.RadioAddress
, settings.Frequency
, settings.Nennweite
, settings.Baulaenge
, settings.PulseModule
, settings.DruckSensor
, rssiLimits.id AS LimitId
, rssiLimits.RSSI_PAM_Min
, rssiLimits.RSSI_PAM_Max
, rssiLimits.RSSI_SEMI_Min
, rssiLimits.RSSI_SEMI_Max
, rssiHistory.id AS RadioId
, rssiHistory.LimitId AS RadioLimitId
, rssiHistory.RSSI_PAM
, rssiHistory.RSSI_SEMI
, rssiHistory.Datum
FROM (SELECT DISTINCT TOP 1
gm.Adresse % 10000000000 AS RadioAddress
, ISNULL(idn.Nennweite, CAST(cms.Dn_RealSize AS INT)) AS Nennweite
, ISNULL(idn.Baulaenge, CAST(_baulaengen.Wert AS INT)) AS Baulaenge
, CASE WHEN _druckSensors.Charcode = 'X' THEN 0 ELSE 1 END AS DruckSensor
, CASE WHEN _frequencies.Charcode = 'A' THEN 868 WHEN _frequencies.Charcode = 'B' THEN 433 ELSE NULL END AS Frequency
, CASE WHEN _pulseModules.Charcode = 'X' THEN 0 ELSE 1 END AS PulseModule
FROM MapPcbIdToSerialNumber AS map
JOIN AuftragPositionSerienNr AS aps
ON map.MapPcbIdToSerialNumber_SerialNumber = aps.SerienNr
LEFT JOIN Genesis_Meter AS gm
ON aps.SerienNr = gm.Seriennummer
JOIN AlleAuftragPositionen AS aap
ON aps.AuftragNr = aap.AuftragNr
AND aps.PositionNr = aap.PositionNr
JOIN Identnr AS idn
ON aap.IdentNr = idn.IdentNr
JOIN AlleIdentNrVakoMerkmale AS _nennweiten
ON aap.IdentNr = _nennweiten.IdentNr
AND _nennweiten.Stelle = 4
JOIN CordonelMeterSizes AS cms
ON _nennweiten.Charcode = cms.Dn_VakoID
JOIN AlleIdentNrVakoMerkmale AS _baulaengen
ON aap.IdentNr = _baulaengen.IdentNr
AND _baulaengen.Stelle = 14
JOIN AlleIdentNrVakoMerkmale AS _druckSensors
ON aap.IdentNr = _druckSensors.IdentNr
AND _druckSensors.Stelle = 22
JOIN AlleIdentNrVakoMerkmale AS _frequencies
ON aap.IdentNr = _frequencies.IdentNr
AND _frequencies.Stelle = 43
JOIN AlleIdentNrVakoMerkmale AS _pulseModules
ON aap.IdentNr = _pulseModules.IdentNr
AND _pulseModules.Stelle = 91
WHERE map.MapPcbIdToSerialNumber_PcbId = @{0})
AS settings
LEFT JOIN Cordonel_Radio_RSSI_Limits AS rssiLimits
ON settings.Frequency = rssiLimits.Frequency
AND settings.Nennweite = rssiLimits.Nennweite
AND (settings.Baulaenge = rssiLimits.Baulaenge OR rssiLimits.Baulaenge = 0)
AND (settings.PulseModule = rssiLimits.Variant_o OR rssiLimits.Variant_o = 0)
AND (settings.DruckSensor = rssiLimits.Variant_p OR rssiLimits.Variant_p = 0)
LEFT JOIN Cordonel_Radio_RSSI_History AS rssiHistory
ON settings.RadioAddress = rssiHistory.RadioAdress
ORDER BY rssiHistory.Datum DESC";
gm.Adresse % 10000000000 AS RadioAddress
, ISNULL(idn.Nennweite, CAST(cms.Dn_RealSize AS INT)) AS Nennweite
, ISNULL(idn.Baulaenge, CAST(_baulaengen.Wert AS INT)) AS Baulaenge
, CASE WHEN _druckSensors.Charcode = 'X' THEN 0 ELSE 1 END AS DruckSensor
, CASE WHEN _frequencies.Charcode = 'A' THEN 868 WHEN _frequencies.Charcode = 'B' THEN 433 ELSE NULL END AS Frequency
, CASE WHEN _pulseModules.Charcode = 'X' THEN 0 ELSE 1 END AS PulseModule
FROM MapPcbIdToSerialNumber AS map
JOIN AuftragPositionSerienNr AS aps
ON map.MapPcbIdToSerialNumber_SerialNumber = aps.SerienNr
LEFT JOIN Genesis_Meter AS gm
ON aps.SerienNr = gm.Seriennummer
JOIN AlleAuftragPositionen AS aap
ON aps.AuftragNr = aap.AuftragNr
AND aps.PositionNr = aap.PositionNr
JOIN Identnr AS idn
ON aap.IdentNr = idn.IdentNr
JOIN AlleIdentNrVakoMerkmale AS _nennweiten
ON aap.IdentNr = _nennweiten.IdentNr
AND _nennweiten.Stelle = 4
JOIN CordonelMeterSizes AS cms
ON _nennweiten.Charcode = cms.Dn_VakoID
JOIN AlleIdentNrVakoMerkmale AS _baulaengen
ON aap.IdentNr = _baulaengen.IdentNr
AND _baulaengen.Stelle = 14
JOIN AlleIdentNrVakoMerkmale AS _druckSensors
ON aap.IdentNr = _druckSensors.IdentNr
AND _druckSensors.Stelle = 22
JOIN AlleIdentNrVakoMerkmale AS _frequencies
ON aap.IdentNr = _frequencies.IdentNr
AND _frequencies.Stelle = 43
JOIN AlleIdentNrVakoMerkmale AS _pulseModules
ON aap.IdentNr = _pulseModules.IdentNr
AND _pulseModules.Stelle = 91
WHERE map.MapPcbIdToSerialNumber_PcbId = @{0})
AS settings
JOIN Cordonel_Radio_RSSI_History AS rssiHistory --> RadioLimitId
ON settings.RadioAddress = rssiHistory.RadioAdress
JOIN Cordonel_Radio_RSSI_Limits AS rssiLimits --> LimitId
ON rssiHistory.LimitId = rssiLimits.id
-- AND rssiLimits.Baulaenge = settings.Baulaenge
-- AND rssiLimits.Frequency = settings.Frequency
-- AND rssiLimits.Nennweite = settings.Nennweite
-- AND rssiLimits.Variant_o = settings.PulseModule
-- AND rssiLimits.Variant_p = settings.DruckSensor
ORDER BY rssiHistory.id DESC";
}
}
@@ -50,26 +50,117 @@
#region Virtual methods used from the Sentinel and Unit Testing
internal virtual IEnumerable<CordonelProductionData> GetProductionData(int pcbId)
=> this.SqlConnection
.CreateCommand(string.Format(ALL_PRODUCTION_DATA_BY_PCB, nameof(pcbId)))
{
var map = this.SqlConnection
.CreateCommand($@"
SELECT DISTINCT
cap.CordonelAssignedPicking_FertigungsAuftragsNr
, map.MapPcbIdToSerialNumber_SerialNumber
, map.MapPcbIdToSerialNumber_PcbId
FROM MapPcbIdToSerialNumber AS map
LEFT JOIN Cordonel_AssignedPicking AS cap
ON map.MapPcbIdToSerialNumber_PcbId = cap.CordonelAssignedPicking_PcbId
WHERE map.MapPcbIdToSerialNumber_PcbId = @{nameof(pcbId)}
AND map.MapPcbIdToSerialNumber_Deleted = 0
AND cap.CordonelAssignedPicking_IsDeleted = 0")
.SetParameter(nameof(pcbId), pcbId)
.ExecuteReader(x => new CordonelProductionData
.ExecuteReader(x => new
{
AuftragNr = x.GetValue<int>(0),
PositionNr = x.GetValue<int>(1),
FertigungsauftragNr = x.GetValue<int>(2),
IdentNr = x.GetValue<int>(3),
RegionSizeKey = x.GetValue<string>(4),
MeterSizeName = x.GetValue<string>(5),
MeterSizeValue = x.GetValue<byte>(6),
KundeneigeneSerienNr = x.GetValue<string>(7),
SerienNr = x.GetValue<int>(8),
PcbId = x.GetValue<int>(9),
Address = x.GetValue<ulong>(10),
PruefgangNr = x.GetValue<int>(11),
StatusFertigung = x.GetValue<int>(12),
EncryptionKeyKind = x.GetValue<CordonelEncryptionKeyKind>(13)
FertigungsauftragNr = x.GetValue<int>(0),
SerienNr = x.GetValue<int>(1),
PcbId = x.GetValue<int>(2),
});
var productionDataList = new List<CordonelProductionData>();
foreach (var item in map)
{
var productionData = this.SqlConnection
.CreateCommand($@"
SELECT TOP 1
aps.AuftragNr
, aps.PositionNr
, aps.SerienNr
, aps.KundeneigeneSerienNr
, aps.StatusFertigung
, aps.Pruefgangnr
, aap.FertigungsauftragNr
, aap.IdentNr
, gm.Adresse % 10000000000
, reg.Charcode
, ms.Dn_Name
, ms.Dn_InternalId
, CASE WHEN fs.Charcode = 'X'
THEN 'None'
WHEN fs.Charcode = '1'
THEN 'Standard'
WHEN fs.Charcode = '2'
THEN 'Random'
WHEN fs.Charcode = '3'
THEN 'CSD'
END AS EncryptionKeyKind
FROM AuftragPositionSerienNr AS aps
LEFT JOIN AlleAuftragPositionen AS aap
ON aps.AuftragNr = aap.AuftragNr
AND aps.PositionNr = aap.PositionNr
LEFT JOIN Genesis_Meter AS gm
ON aps.SerienNr = gm.Seriennummer
LEFT JOIN AlleIdentNrVakoMerkmale AS reg
ON aap.IdentNr = reg.IdentNr
AND reg.Stelle = 4
AND reg.Laenge = 2
LEFT JOIN CordonelMeterSizes AS ms
ON reg.Charcode = ms.Dn_VakoID
LEFT JOIN AlleIdentNrVakoMerkmale AS fs
ON aap.IdentNr = fs.IdentNr
AND fs.Stelle = 46
AND fs.Laenge = 1
WHERE aps.SerienNr = @{nameof(item.SerienNr)}
ORDER BY aps.Pruefgangnr DESC")
.SetParameter(nameof(item.SerienNr), item.SerienNr)
.FirstOrDefault(x => new CordonelProductionData
{
PcbId = item.PcbId,
AuftragNr = x.GetValue<int>(0),
PositionNr = x.GetValue<int>(1),
SerienNr = x.GetValue<int>(2),
KundeneigeneSerienNr = x.GetValue<string>(3),
StatusFertigung = x.GetValue<StatusFertigung>(4),
PruefgangNr = x.GetValue<int>(5),
FertigungsauftragNr = x.GetValue<int>(6),
IdentNr = x.GetValue<int>(7),
Address = x.GetValue<ulong>(8),
RegionSizeKey = x.GetValue<string>(9),
MeterSizeName = x.GetValue<string>(10),
MeterSizeValue = x.GetValue<byte>(11),
EncryptionKeyKind = x.GetValue<CordonelEncryptionKeyKind>(12)
});
productionDataList.Add(productionData);
}
return productionDataList;
//return this.SqlConnection
// .CreateCommand(string.Format(ALL_PRODUCTION_DATA_BY_PCB, nameof(pcbId)))
// .SetParameter(nameof(pcbId), pcbId)
// .ExecuteReader(x => new CordonelProductionData
// {
// AuftragNr = x.GetValue<int>(0),
// PositionNr = x.GetValue<int>(1),
// FertigungsauftragNr = x.GetValue<int>(2),
// IdentNr = x.GetValue<int>(3),
// RegionSizeKey = x.GetValue<string>(4),
// MeterSizeName = x.GetValue<string>(5),
// MeterSizeValue = x.GetValue<byte>(6),
// KundeneigeneSerienNr = x.GetValue<string>(7),
// SerienNr = x.GetValue<int>(8),
// PcbId = x.GetValue<int>(9),
// Address = x.GetValue<ulong>(10),
// PruefgangNr = x.GetValue<int>(11),
// StatusFertigung = x.GetValue<StatusFertigung>(12),
// EncryptionKeyKind = x.GetValue<CordonelEncryptionKeyKind>(13)
// });
}
internal virtual EOLProgressModel GetEOLProgressModel(int pcbId)
=> this.EOLProgress.Read(pcbId);
@@ -113,10 +204,11 @@
FileName = reader.GetValue<string>(15),
});
internal virtual IEnumerable<CordonelAppVeriosnCrc> GetLatestAppsWithVersions(int pcbId)
internal virtual IEnumerable<CordonelAppVeriosnCrc> GetLatestAppsWithVersions(int pcbId, string fwVersion, bool isSpecial)
=> this.SqlConnection
.CreateCommand(string.Format(LATEST_APPS_VERSIONS_CRC_BY_PCB, nameof(pcbId)))
.CreateCommand(string.Format(LATEST_APPS_VERSIONS_CRC_BY_PCB, nameof(pcbId), nameof(fwVersion)))
.SetParameter(nameof(pcbId), pcbId)
.SetParameter(nameof(fwVersion), fwVersion)
.ExecuteReader(reader => new CordonelAppVeriosnCrc
{
AppsPcbId = reader.GetValue<int>(0),
@@ -46,21 +46,21 @@
try
{
// Data loading
this.TryGetUniqueProductionData(pcbId, out var productionData); // Tested
this.TryGetEOLProgressModel(pcbId, out var eolProgress); // Tested
this.TryGetCordonelRequirements(pcbId, out var requirements); // Tested
this.TryGetProgrammingParameters(pcbId, out var parameters);
this.TryGetCordonelAppsAndRegisterValues(pcbId, out var apps); // Tested
this.TryGetCordonelAppsAndFWVersionValues(pcbId, requirements.FwVersion, out var appsVersionsCrcs); // Tested
this.TryGetCordonelMetrologyValues(pcbId, requirements.SkipCalibration, out var metrologyValues); // Tested
this.TryGetCordonelRadioDefaults(pcbId, requirements.SkipRadioCheck, out var rssiValues); // Tested
this.TryGetPasswordFileContent(pcbId, out var passwordFile);
this.TryGetUniqueProductionData(pcbId, out var productionData);
this.TryGetEOLProgressModel(pcbId, out var eolProgress);
this.TryGetCordonelRequirements(pcbId, out var requirements);
this.TryGetProgrammingParameters(pcbId, out var parameters); // slow
this.TryGetCordonelAppsAndRegisterValues(pcbId, out var apps); // slow
this.TryGetCordonelAppsAndFWVersionValues(pcbId, requirements, out var appsVersionsCrcs); // slow
this.TryGetCordonelMetrologyValues(pcbId, requirements.SkipCalibration, out var metrologyValues); // very slow
this.TryGetCordonelRadioDefaults(pcbId, requirements.SkipRadioCheck, out var rssiValues);
this.TryGetPasswordFileContent(pcbId, out var passwordFile); // ~ slow
// Data comparison
this.TryCompareRequirementsIdAndVersion(eolProgress, requirements); // Tested
this.TryCompareRequirementsIdAndVersion(eolProgress, requirements);
this.TryCompareAllPcbIds(pcbId, productionData, requirements, apps, eolProgress, metrologyValues);
this.TryCompareProductionOrderNumber(productionData, requirements, eolProgress);
this.TryCompareRegionSizeKey(productionData, requirements, eolProgress); // Tested
this.TryCompareRegionSizeKey(productionData, requirements, eolProgress);
this.TryCompareMeterSize(productionData, requirements, eolProgress, apps, metrologyValues);
this.TryCompareLUTCRCVersion(requirements, eolProgress, apps);
this.TryCompareAppsAndFWVersion(requirements, eolProgress, apps, appsVersionsCrcs);
@@ -287,26 +287,29 @@
}
var utcNow = DateTime.UtcNow;
var utcMonth = utcNow.Month;
var kitronProductionDate = utcNow.AddSeconds(-exceededLifeTime_seconds);
var kitronMonth = kitronProductionDate.Month;
var year = utcNow.Year;
var days = 0;
var kitronDateUtc = utcNow.AddSeconds(-exceededLifeTime_seconds);
var kitronTotalDays = (utcNow - kitronDateUtc).TotalDays;
var kitronMonths = 0;
for (var month = kitronMonth; month < utcMonth; month++)
while (true)
{
days += DateTime.DaysInMonth(year, month);
year = utcNow.AddMonths(1).Year;
var daysInMonth = DateTime.DaysInMonth(kitronDateUtc.Year, kitronDateUtc.Month);
kitronTotalDays -= daysInMonth;
if (kitronTotalDays < 0)
{
break;
}
kitronMonths++;
}
var storageMonths = (utcMonth - kitronMonth + 1.0) / days * 100;
if (storageMonths > requirements.MaxStorageMonths)
if (kitronMonths > requirements.MaxStorageMonths)
{
this.ThrowSentinelException(
nameof(Apps.POWERMON)
, nameof(POWERMON.TotalUsedSeconds)
, kitronProductionDate
, kitronDateUtc
, ">"
, nameof(CordonelRequirements)
, nameof(CordonelRequirements.MaxStorageMonths)
@@ -415,7 +418,8 @@
var genesisFlowApp = apps[Apps.GENESISFLOW];
var lookupFileCrcReg = genesisFlowApp[GENESISFLOW.LookupFileCrc];
var lookUpFileCrcValue = lookupFileCrcReg.GetValue<ushort>();
var appLutCrcName = $"0x{lookUpFileCrcValue:X2}";
var lookUpFileCrcBytes = BitConverter.GetBytes(lookUpFileCrcValue);
var appLutCrcName = $"0x{lookUpFileCrcBytes[1]:X2}{lookUpFileCrcBytes[0]:X2}";
if (requirements.LutCrc != eolProgress.ProductionStatusLutCrc)
{
@@ -502,7 +506,7 @@
return;
}
if (productionData.StatusFertigung != 30)
if (productionData.StatusFertigung != StatusFertigung.OK)
{
this.ThrowSentinelException(nameof(TryGetUniqueProductionData), $"{nameof(productionData.StatusFertigung)} != 30");
}
@@ -692,16 +696,16 @@
, nameof(CordonelRSSIValues.RadioCheckId)
, rssiValues.RadioCheckId);
}
else if (rssiValues.LimitId != rssiValues.RadioLimitId)
{
this.ThrowSentinelException(
nameof(CordonelRSSIValues)
, nameof(CordonelRSSIValues.LimitId)
, rssiValues.LimitId
, nameof(CordonelRSSIValues)
, nameof(CordonelRSSIValues.RadioLimitId)
, rssiValues.RadioLimitId);
}
//else if (rssiValues.LimitId != rssiValues.RadioLimitId)
//{
// this.ThrowSentinelException(
// nameof(CordonelRSSIValues)
// , nameof(CordonelRSSIValues.LimitId)
// , rssiValues.LimitId
// , nameof(CordonelRSSIValues)
// , nameof(CordonelRSSIValues.RadioLimitId)
// , rssiValues.RadioLimitId);
//}
else if (rssiValues.RSSI_PAM_Min > rssiValues.RSSI_PAM || rssiValues.RSSI_PAM > rssiValues.RSSI_PAM_Max)
{
this.ThrowSentinelException($"{nameof(CordonelRSSIValues)}.{nameof(rssiValues.RSSI_PAM)}({rssiValues.RSSI_PAM}) ist auserhalb der bereich: {rssiValues.RSSI_PAM} <= x <= {rssiValues.RSSI_PAM_Max}");
@@ -844,7 +848,9 @@
this.ThrowSentinelException(nameof(TryGetCordonelAppsAndRegisterValues), $"{nameof(CordonelAppsDictionary)} ist erforderlich");
}
var registerHistoryValues = this.cordonelDbContext.GetLatestRegistersWithValues(pcbId);
var registerHistoryValues = this.cordonelDbContext
.GetLatestRegistersWithValues(pcbId)
.ToArray();
if (registerHistoryValues is null)
{
@@ -861,10 +867,13 @@
}
}
internal void TryGetCordonelAppsAndFWVersionValues(int pcbId, string version, out CordonelAppVeriosnCrc[] appsVersionsCrc)
internal void TryGetCordonelAppsAndFWVersionValues(int pcbId, CordonelRequirements requirements, out CordonelAppVeriosnCrc[] appsVersionsCrc)
{
var fwVersion = requirements?.FwVersion;
var isSpecial = requirements?.IsSpecialActive == true && requirements?.IsSpecialApproved == true;
appsVersionsCrc = this.cordonelDbContext
?.GetLatestAppsWithVersions(pcbId)
?.GetLatestAppsWithVersions(pcbId, fwVersion, isSpecial)
?.ToArray();
if (appsVersionsCrc is null)
@@ -882,7 +891,7 @@
metrologyValues = this.meterProcessState?.GetLatestGenesisFlowValues(pcbId);
//TODO: Sentinel: load values from independent source (this.cordonelDbContext?.GetLatestGenesisFlowValues(pcbId));
if (metrologyValues is null)
if (metrologyValues is null && skipMetrology != true)
{
this.ThrowSentinelException(nameof(TryGetCordonelMetrologyValues), $"{nameof(CordonelMetrologyValues)} für PcbId: {pcbId} nicht verfügbar");
}
@@ -977,9 +986,11 @@
"GENESISFLOW_TriggerActive", // Does NOT respond
"SENSUSRADIO_CurrentLoopMax", // Does NOT respond
"SENSUSRADIO_CurrentLoopSource", // Does NOT respond
"SENSUSRADIO_CustomerText" // Does NOT respond
"SENSUSRADIO_CustomerText", // Does NOT respond
"CUSTOMER_AlarmEnableMask", // 2025-02-13 FW (R1.3.10, R1.4.15) issue
"CUSTOMER_AlarmVisualMask", // 2025-02-13 FW (R1.3.10, R1.4.15) issue
};
var results = this.meterProcessState
.GetCordonelProgrammingParameters(pcbId)
.OrderBy(x => x.Source);
@@ -471,7 +471,8 @@
<Error Condition="!Exists('..\packages\Microsoft.Bcl.Build.1.0.21\build\Microsoft.Bcl.Build.targets')" Text="$([System.String]::Format('$(ErrorText)', '..\packages\Microsoft.Bcl.Build.1.0.21\build\Microsoft.Bcl.Build.targets'))" />
</Target>
<PropertyGroup>
<PreBuildEvent>$(SolutionDir)RoutesBuilder\bin\Debug\RoutesBuilder.exe</PreBuildEvent>
<PreBuildEvent>
</PreBuildEvent>
</PropertyGroup>
<PropertyGroup>
<PostBuildEvent>del "$(TargetDir)*.pdb"
+1 -1
View File
@@ -12,7 +12,7 @@
var prefixes = new StringBuilder();
var solutionDirectory = new DirectoryInfo(@"..\..\..\").FullName;
var laaProductionWeb = Path.Combine(solutionDirectory, @"LaaProductionWeb\LaaProductionWeb");
var laaProductionWeb = Path.Combine(solutionDirectory, @"LaaProductionWeb");
var appInfrastructure = Path.Combine(laaProductionWeb, "App_Infrastructure");
var apiControllers = new DirectoryInfo(Path.Combine(laaProductionWeb, "API"));
var controllers = apiControllers