MagFlux equalize data format of streaming and response for:
- UniqueId as Hex-String with leading "0x", - SensorId as Decimal-String
This commit is contained in:
@@ -48,7 +48,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.DataPackages.MeasurementRecor
|
||||
.Append($"FlowRate [m³/h]: {FlowRateCmPh}").Append(StringDelimiter)
|
||||
.Append($"Status: 0x{StatusBits:X8}").Append(StringDelimiter)
|
||||
.Append($"UniqueId: {UniqueId}").Append(StringDelimiter)
|
||||
.Append($"SensorSN: {SensorId}").Append(StringDelimiter)
|
||||
.Append($"SensorId: {SensorId}").Append(StringDelimiter)
|
||||
.Append($"CRC: 0x{Crc:X4}").Append(StringDelimiter)
|
||||
.Append($"OverflowVolume [m³]: {OverflowVolumeCm}").Append(StringDelimiter)
|
||||
.Append($"OverflowTime [s]: {OverflowTimeS}").Append(StringDelimiter)
|
||||
|
||||
@@ -46,7 +46,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Wrapper to connect mag flux
|
||||
/// Wrapper to connect MagFlux
|
||||
/// </summary>
|
||||
/// <param name="portName"></param>
|
||||
/// <returns></returns>
|
||||
@@ -74,7 +74,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
|
||||
return retVal;
|
||||
}
|
||||
/// <summary>
|
||||
/// Wrapper to connect mag flux
|
||||
/// Wrapper to close the connection to the MagFlux
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
/// <remarks date="2023-Mai-04" author="T.Wiedebusch">
|
||||
@@ -87,7 +87,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
|
||||
return retVal;
|
||||
}
|
||||
/// <summary>
|
||||
/// Wrapper to connect mag flux
|
||||
/// Wrapper to connect MagFlux
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
/// <remarks date="2023-Mai-04" author="T.Wiedebusch">
|
||||
@@ -100,7 +100,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
|
||||
return retVal;
|
||||
}
|
||||
/// <summary>
|
||||
/// Wrapper to get FW version
|
||||
/// Wrapper to get FW version of MagFlux
|
||||
/// </summary>
|
||||
/// <param name="fwVersion"></param>
|
||||
/// <returns></returns>
|
||||
@@ -116,7 +116,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Wrapper to get FW GIT hash
|
||||
/// Wrapper to get FW GIT hash of MagFlux
|
||||
/// </summary>
|
||||
/// <param name="fwGitHash"></param>
|
||||
/// <returns></returns>
|
||||
|
||||
@@ -175,7 +175,9 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.StreamingProtocol
|
||||
|
||||
// adding the hex identifier, as this is not part of the string
|
||||
dataMagFluxRec.UniqueId = $"0x{fields[(Int32)ProtLsubString.UniqueId]}";
|
||||
dataMagFluxRec.SensorId = $"0x{fields[(Int32)ProtLsubString.SensorId]}";
|
||||
var decimalSensorId = UInt32.Parse(fields[(Int32)ProtLsubString.SensorId], NumberStyles.AllowHexSpecifier);
|
||||
|
||||
dataMagFluxRec.SensorId = decimalSensorId.ToString();
|
||||
}
|
||||
|
||||
/// field position in protocol 'l'
|
||||
|
||||
Reference in New Issue