672 lines
32 KiB
C#
672 lines
32 KiB
C#
///
|
|
/// Copyright (c) 2013-2017 Sensus Metering Systems
|
|
///
|
|
using System;
|
|
using System.Collections.Generic;
|
|
using System.Text;
|
|
using log4net;
|
|
using TBF.BenchControl;
|
|
using TBF.Boxes;
|
|
using TBF.Resources;
|
|
using TBF.UiBridge;
|
|
|
|
namespace TBF.BenchControl.TestMethods.FlyingStart
|
|
{
|
|
public class FlyingStartSeq : Sequences.SequenceBase
|
|
{
|
|
private static readonly ILog log = LogManager.GetLogger(typeof(FlyingStartSeq));
|
|
|
|
/// <summary>
|
|
/// Flying start mass collection method sequence
|
|
/// </summary>
|
|
/// <param name="test">Test entity</param>
|
|
/// <returns>
|
|
/// Event.Done . . . . . . . OK
|
|
/// Event.UiCmdStop . . . . Stopped by the user using the on-screen button STOP
|
|
/// Event.OpArgumentError . Target flow is out of range
|
|
/// Event.Error . . . . . . Unspecified error
|
|
/// </returns>
|
|
public IList<Event> Execute(Config.Entities.Test test, bool outerLoopMode, int outerLoopCounter,
|
|
Compound.TestParams compoundTestParams,
|
|
HeatMeters.TestParams heatMetersTestParams,
|
|
Config.Entities.DebugMode debugLevel)
|
|
{
|
|
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
|
Event retVal = Event.Done;
|
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
|
///
|
|
if (debugLevel == Config.Entities.DebugMode.Simulate)
|
|
{
|
|
///
|
|
/// Test method simulation
|
|
///
|
|
TestProgressEventArgs.SetEstimatedTimes(new int[] { 0, 0, 0, 30, 0, 30, 0, 0 });
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, Config.Entities.Progress.JustStarted));
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, Config.Entities.Progress.FlowSetting));
|
|
|
|
if (compoundTestParams != null)
|
|
{
|
|
if (test.Name.ToLower().Contains("nok")) MakeSimulatedCompound(test.Name, 1, 1, 0, 4.7f, 0.9f);
|
|
else MakeSimulatedCompound(test.Name, 1, 1, 0, 0.7f, 1.0f);
|
|
}
|
|
else if (heatMetersTestParams != null)
|
|
{
|
|
MakeSimulatedHeatMeters(test.Name, 1, 1, 0, 1.5f, 1000000, heatMetersTestParams.ErrorLimitLo, heatMetersTestParams.ErrorLimitHi, heatMetersTestParams.EvaluateVolume);
|
|
}
|
|
else if (test.Name.ToLower().Contains("q3")) MakeSimulated(test.Name, 1, 1, 0, -0.5f);
|
|
else if (test.Name.ToLower().Contains("q2")) MakeSimulated(test.Name, 1, 1, 0, 0.5f);
|
|
else if (test.Name.ToLower().Contains("q1")) MakeSimulated(test.Name, 1, 1, 0, -5.1f);
|
|
else MakeSimulated(test.Name, 1, 1, 0, 0.9f);
|
|
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, Config.Entities.Progress.Completed));
|
|
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(test.Name, BatchRslts.GetTestRslt(Results.Utils.GetTestName(test.Name, 1, 1), 0)));
|
|
allResults.Info(TestResult2CsvLine(test.Name, 0)); /// Append the results to the CSV-file
|
|
|
|
for (int i = 0; i < Config.Data.WMsCount; i++)
|
|
{
|
|
TestMethods.iPerlCommunication.iPerlHead.IperlHead iPerl = ((sensPath.RegisterReaders != null) && (i < sensPath.RegisterReaders.Length))
|
|
? (sensPath.RegisterReaders[i] as TestMethods.iPerlCommunication.iPerlHead.IperlHead)
|
|
: null;
|
|
if (iPerl != null)
|
|
{
|
|
/// TODO: Reimplement
|
|
//iPerl.LastTestResult = meterRslt; /// Save this water meter test result to iPerl WM
|
|
iPerl.NominalTestFlowLph = 500.0 * (double)(test.Qfrom + test.Qto); /// Ave. + convert to liter/hour
|
|
}
|
|
}
|
|
|
|
//------------------------------------------------------------------
|
|
Bridge.OnActivity(this, string.Format("{0} simulation", test.Name));
|
|
//------------------------------------------------------------------
|
|
|
|
State.Create(string.Format("{0}({1}) : Simulating {0}", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.EnterState();
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
|
|
if (TestAndLogUiCmdStop(test, e)) retVal = Event.UiCmdStop;
|
|
|
|
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
|
IList<Event> retListSim = new List<Event>(1);
|
|
retListSim.Add(retVal);
|
|
return retListSim;
|
|
}
|
|
|
|
|
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
|
|
|
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
|
|
|
/// Notes:
|
|
/// float timeHr = volumeLtr / (1000.0f * targetFlow);
|
|
/// float timeSec = 3600.0f * timeHr;
|
|
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
|
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
|
|
|
int repetitionNr = outerLoopMode ? outerLoopCounter : 1; /// First test: repetitionNr=1
|
|
|
|
//====================================
|
|
// Transition or SetRoute - Start
|
|
//====================================
|
|
switch (Transition(transitionBefore, TransitionContext.BeforeTest))
|
|
{
|
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
|
}
|
|
|
|
//====================================
|
|
loop:
|
|
/// Start the test, initialize test results
|
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
|
TestStartTime = DateTime.Now;
|
|
TestProgressEventArgs.SetEstimatedTimes(new int[] { 1, 1, 1, 30, 0, Convert.ToInt32(test.TstTime) + 15, 0, 0 });
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
|
|
|
|
|
///
|
|
/// Optionally display prompt to emerge temperature meters to appropriate baths for heat meters test
|
|
///
|
|
IOperation heatMetersPromptOp = null;
|
|
if (heatMetersTestParams != null && !string.IsNullOrEmpty(heatMetersTestParams.Prompt))
|
|
{
|
|
/// Make sure the CycleBeginForm is closed
|
|
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
|
|
|
heatMetersPromptOp = new Operations.MessageBoxOp(heatMetersTestParams.Prompt);
|
|
}
|
|
|
|
//------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Starting_the_pump);
|
|
//------------------------------------------------
|
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
|
///
|
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
|
|
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
|
.AddOperation(heatMetersPromptOp)
|
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
|
.EnterState();
|
|
do
|
|
{
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
|
}
|
|
while (e.Contains(Event.ValvesBusy) /* || !e.Contains(Event.AllPositionsReached)*/);
|
|
|
|
//------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
|
//------------------------------------------------
|
|
int flowSetTime0 = StateMachine.Time;
|
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, 990)) /// timeout = 16.5 min.
|
|
.AddOperation(heatMetersPromptOp)
|
|
.EnterState();
|
|
do
|
|
{
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
|
|
if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; }
|
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
if (e.Contains(Event.RegulValveTimeOut))
|
|
{
|
|
Bridge.OnError(this, Strings.Timeout);
|
|
retVal = Event.Done;
|
|
goto stopTest;
|
|
}
|
|
if (e.Contains(Event.Next)) goto flow_set;
|
|
}
|
|
while (!e.Contains(Event.FlowReached));
|
|
|
|
flow_set:
|
|
|
|
int flowSetTime = StateMachine.Time - flowSetTime0;
|
|
double currentFlow = RefFlow.Val;
|
|
|
|
if (heatMetersTestParams != null && heatMetersPath != null)
|
|
{
|
|
//---------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Setting_temperature);
|
|
//---------------------------------------------------
|
|
|
|
int lastTimeSec = StateMachine.Time;
|
|
double Tw_last = 0;
|
|
double Tc_last = 0;
|
|
|
|
State.Create(string.Format("{0}({1}) : Checking if the temperature is stable", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
.AddOperation(heatMetersPromptOp)
|
|
.EnterState();
|
|
do
|
|
{
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
if (e.Contains(Event.Next)) goto temperature_set;
|
|
|
|
if (TempRefHi1.Val != 0 && TempRefHi2.Val != 0 && TempRefLo1.Val != 0 && TempRefLo2.Val != 0)
|
|
{
|
|
if (StateMachine.Time - lastTimeSec > 10 || StateMachine.Time - lastTimeSec < 0)
|
|
{
|
|
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
|
|
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
|
|
if (heatMetersTestParams.TempWarmLo <= Tw && Tw <= heatMetersTestParams.TempWarmHi &&
|
|
heatMetersTestParams.TempColdLo <= Tc && Tc <= heatMetersTestParams.TempColdHi &&
|
|
Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm &&
|
|
Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold &&
|
|
Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm &&
|
|
Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold)
|
|
{
|
|
goto temperature_set;
|
|
}
|
|
|
|
lastTimeSec = StateMachine.Time;
|
|
Tw_last = Tw;
|
|
Tc_last = Tc;
|
|
}
|
|
}
|
|
}
|
|
while (true);
|
|
}
|
|
else if (test.DoControlWaterTemp && benchPath.TempMtrUp != null && benchPath.TempMtrDown != null)
|
|
{
|
|
//---------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Setting_temperature);
|
|
//---------------------------------------------------
|
|
|
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
|
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
.EnterState();
|
|
do
|
|
{
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
if (e.Contains(Event.Next)) goto temperature_set;
|
|
|
|
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
|
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
|
{
|
|
goto temperature_set;
|
|
}
|
|
}
|
|
while (true);
|
|
}
|
|
|
|
temperature_set:
|
|
|
|
|
|
///
|
|
/// Prepare cameras, ROI-s and measurementOperations
|
|
///
|
|
|
|
/// Find ROI-s
|
|
IList<GenericDevices.IRoi> rois = new List<GenericDevices.IRoi>();
|
|
foreach (var rr in sensPath.RegisterReaders)
|
|
{
|
|
GenericDevices.IRoi roi = rr as GenericDevices.IRoi;
|
|
if (roi != null && roi.Detected)
|
|
{
|
|
rois.Add(roi);
|
|
}
|
|
}
|
|
|
|
/// Find cameras
|
|
IList<GenericDevices.ICamera> cameras = new List<GenericDevices.ICamera>();
|
|
foreach (var roi in rois)
|
|
{
|
|
if (roi.Camera != null && !cameras.Contains(roi.Camera))
|
|
{
|
|
roi.Camera.ClearRoiParams();
|
|
cameras.Add(roi.Camera);
|
|
}
|
|
}
|
|
|
|
/// Register ROI-parameters to cameras
|
|
foreach (var roi in rois) roi.RegisterRoiToCamera();
|
|
|
|
/// Prepare measurementOperations
|
|
IList<IOperation> measureOperations = new List<IOperation>();
|
|
foreach (var camera in cameras) measureOperations.Add(camera.MeasurementOp());
|
|
|
|
|
|
|
|
//------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
|
//------------------------------------------------
|
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(measureOperations)
|
|
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
|
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
|
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
|
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
.AddOperation((StateMachine.Ambient != null)
|
|
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
.AddOperation(processDataLoggingOp)
|
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro,
|
|
test.Qfrom, test.Qto, totalPulses, (float)test.TolerRed))
|
|
.EnterState();
|
|
do
|
|
{
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
}
|
|
while (!e.Contains(Event.MeasurementStarted));
|
|
|
|
|
|
foreach (var rr in sensPath.RegisterReaders)
|
|
{
|
|
if (rr is TestMethods.iPerlCommunication.iPerlHead.IperlHead)
|
|
{
|
|
(rr as TestMethods.iPerlCommunication.iPerlHead.IperlHead).TestName = test.Name;
|
|
}
|
|
}
|
|
|
|
|
|
/// Measurement loop - preparation
|
|
readRegistersOp = new Operations.ReadMoreRegistersOp(sensPath.RegisterReaders);
|
|
queryEnd1 = cBrd.QueryMeasurementEndOp();
|
|
|
|
int estimtdEndTime = StateMachine.Time + (int)test.TstTime;
|
|
ClearAllStatistics(StateMachine.Time);
|
|
|
|
/// Measurement loop - begin
|
|
State.Create("Read water meters")
|
|
.AddOperation(checkUiOp)
|
|
.AddOperations(measureOperations)
|
|
.AddOperation(readRegistersOp)
|
|
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
|
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
|
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
|
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
.AddOperation((StateMachine.Ambient != null)
|
|
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
|
|
: null)
|
|
.AddOperation(queryEnd1)
|
|
.AddOperation(processDataLoggingOp)
|
|
.EnterState();
|
|
do
|
|
{
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
|
if (e.Contains(Event.MeasurementCompleted)) goto test_completed;
|
|
|
|
//------------------------------------------------
|
|
int remainingTime = Math.Max(estimtdEndTime - StateMachine.Time, 0);
|
|
if (remainingTime > 60)
|
|
{
|
|
Bridge.OnActivity(this, string.Format("{0} ... {1} {2} {3} {4}", Strings.Test_in_progress, remainingTime / 60, "min", remainingTime % 60, Strings.sec));
|
|
}
|
|
else
|
|
{
|
|
Bridge.OnActivity(this, string.Format("{0} ... {1} s", Strings.Test_in_progress, remainingTime));
|
|
}
|
|
//------------------------------------------------
|
|
|
|
RefFreq.Val = cBrd.ReferenceFreq;
|
|
RefFlow.Val = cBrd.ReferenceFlow;
|
|
|
|
UpdateAllStatistics(StateMachine.Time);
|
|
|
|
if (heatMetersTestParams != null)
|
|
{
|
|
if (lastEnergyUpdateTime == 0)
|
|
{
|
|
lastEnergyUpdateTime = StateMachine.Time;
|
|
}
|
|
else
|
|
{
|
|
//double deltaTime = (double)(StateMachine.Time - lastEnergyUpdateTime);
|
|
double T_in = (TempRefHi1.Val + TempRefHi2.Val) / 2; /// [°C]
|
|
double T_out = (TempRefLo1.Val + TempRefLo2.Val) / 2; /// [°C]
|
|
double deltaVolume = LtrPerRefPulse * RefPulsesDelta; /// [l]
|
|
double deltaEnergy = (0.001 * deltaVolume) * (T_in - T_out) * Formulas.HeatCoefficientWater(16, T_in, T_out, heatMetersTestParams.FlowMeasuredAtHiTempPipe); /// [J] = [m3] * [K] * [J/(m3 K)]
|
|
Energy.Update(deltaEnergy);
|
|
VolumeForEnergy.Update(deltaVolume);
|
|
lastEnergyUpdateTime = StateMachine.Time;
|
|
}
|
|
}
|
|
|
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
|
}
|
|
while (true);
|
|
/// Measurement loop - end
|
|
|
|
test_completed:
|
|
|
|
//------------------------------------------------
|
|
Bridge.OnActivity(this, Strings.Test_completed);
|
|
//------------------------------------------------
|
|
|
|
TestEndTime = DateTime.Now;
|
|
|
|
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
|
|
if (heatMetersPromptOp == null)
|
|
{
|
|
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
|
|
}
|
|
|
|
///
|
|
/// Populate TestResult data entity with data
|
|
///
|
|
Results.Entities.TestRslt tstRslt = BatchRslts.GetTestRslt(testName, test.Part);
|
|
|
|
if (tstRslt != null)
|
|
{
|
|
UpdateTempPressDensAmb(tstRslt);
|
|
|
|
/// Main results
|
|
tstRslt.StartTime = TestStartTime;
|
|
tstRslt.EndTime = TestEndTime;
|
|
tstRslt.FlowSetTime = flowSetTime;
|
|
tstRslt.TestTime = cBrd.TTime; /// [s] measurement time
|
|
tstRslt.PulsesMaster = Convert.ToDouble(cBrd.EtPulses(0)); /// Pulses of the master flow meter (test total)
|
|
tstRslt.MassStartRaw = 0;
|
|
tstRslt.MassStart = 0;
|
|
tstRslt.MassEndRaw = 0;
|
|
tstRslt.MassEnd = 0;
|
|
tstRslt.FlowMass = 0; /// [kg/h]
|
|
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
|
|
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
|
tstRslt.ConstMaster = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume); /// Corrected master pulses per liter
|
|
tstRslt.VolumeCTV = tstRslt.ConstMaster * tstRslt.PulsesMaster; /// [l] 1000.0f is because density is in [kg/m3]
|
|
tstRslt.ErrorMaster = 0.0; /// Cannot be determined without a mass measurement
|
|
|
|
tstRslt.FlowMean = (float)RefFlowStat.Average;
|
|
tstRslt.FlowMin = (float)RefFlowStat.Min;
|
|
tstRslt.FlowMax = (float)RefFlowStat.Max;
|
|
|
|
if (compoundTestParams != null)
|
|
{
|
|
///
|
|
/// Compound meters
|
|
///
|
|
/// TODO
|
|
}
|
|
else if (heatMetersTestParams != null)
|
|
{
|
|
///
|
|
/// Heat meters
|
|
///
|
|
tstRslt.RefEnergy = Energy.Sum * tstRslt.VolumeCTV / VolumeForEnergy.Sum; /// [J] = [J] * [l] / [l]
|
|
|
|
tstRslt.Custom1 = (float)TempRefHiStat.Average;
|
|
tstRslt.Custom2 = (float)TempRefHiStat.First;
|
|
tstRslt.Custom3 = (float)TempRefHiStat.Last;
|
|
tstRslt.Custom4 = (float)TempRefHiStat.Min;
|
|
tstRslt.Custom5 = (float)TempRefHiStat.Max;
|
|
tstRslt.Custom6 = (float)TempRefLoStat.Average;
|
|
tstRslt.Custom7 = (float)TempRefLoStat.First;
|
|
tstRslt.Custom8 = (float)TempRefLoStat.Last;
|
|
tstRslt.Custom9 = (float)TempRefLoStat.Min;
|
|
tstRslt.Custom10 = (float)TempRefLoStat.Max;
|
|
|
|
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
|
|
{
|
|
if (test.Part != 0 && test.Part != Utils.PartNr(i + 1, BatchRslts.Batch.Compound)) continue;
|
|
|
|
Results.Entities.MeterTestRslt volumeRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterVolume);
|
|
Results.Entities.MeterTestRslt energyRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterEnergy);
|
|
|
|
BenchControl.GenericDevices.IRegisterReader volumeRegReader =
|
|
(sensPath.RegisterReaders.Length > 2 * i) ? sensPath.RegisterReaders[2 * i] : null;
|
|
|
|
BenchControl.GenericDevices.IRegisterReader energyRegReader =
|
|
(sensPath.RegisterReaders.Length > 2 * i + 1) ? sensPath.RegisterReaders[2 * i + 1] : null;
|
|
|
|
if (volumeRslt != null && volumeRegReader != null)
|
|
{
|
|
volumeRslt.PulsesPerLiter = volumeRegReader.PulsesPerLtr; /// [l ^ -1]
|
|
volumeRslt.PulsesMeter = Convert.ToDouble(volumeRegReader.WMPulses);
|
|
volumeRslt.PulsesMaster = Convert.ToDouble(volumeRegReader.WMRefPulses);
|
|
volumeRslt.VolumeStart = 0;
|
|
volumeRslt.VolumeEnd = 0;
|
|
volumeRslt.VolumeMeter = volumeRslt.PulsesMeter * volumeRegReader.LtrsPerPulse; /// [l]
|
|
volumeRslt.VolumeRef = volumeRslt.PulsesMaster * tstRslt.ConstMaster; /// [l]
|
|
volumeRslt.TestTime = tstRslt.TestTime; /// [s]
|
|
|
|
volumeRslt.Error = Formulas.ErrorFromVolumes(volumeRslt.VolumeMeter, volumeRslt.VolumeRef);
|
|
volumeRslt.Passed = !heatMetersTestParams.EvaluateVolume ||
|
|
((volumeRslt.Error >= test.ErrLimLo + test.Uncertainty) &&
|
|
(volumeRslt.Error <= test.ErrLimHi - test.Uncertainty));
|
|
volumeRslt.TestDone = true;
|
|
tstRslt.TestDone = true;
|
|
}
|
|
|
|
if (energyRslt != null && energyRegReader != null)
|
|
{
|
|
energyRslt.PulsesPerLiter = energyRegReader.PulsesPerLtr; /// [kWh ^ -1]
|
|
energyRslt.PulsesMeter = Convert.ToDouble(energyRegReader.WMPulses);
|
|
energyRslt.PulsesMaster = Convert.ToDouble(energyRegReader.WMRefPulses);
|
|
energyRslt.VolumeStart = 0;
|
|
energyRslt.VolumeEnd = 0;
|
|
energyRslt.VolumeRef = tstRslt.RefEnergy * (energyRslt.PulsesMaster / tstRslt.PulsesMaster); /// [J]
|
|
energyRslt.VolumeMeter = energyRslt.PulsesMeter * Config.Units.ConvertFrom(Config.Unit.kWh, energyRegReader.LtrsPerPulse); /// [J]
|
|
energyRslt.TestTime = tstRslt.TestTime; /// [s]
|
|
|
|
energyRslt.Error = Formulas.ErrorFromVolumes(energyRslt.VolumeMeter, energyRslt.VolumeRef);
|
|
energyRslt.Passed = (energyRslt.Error >= heatMetersTestParams.ErrorLimitLo)
|
|
&& (energyRslt.Error <= heatMetersTestParams.ErrorLimitHi);
|
|
energyRslt.TestDone = true;
|
|
tstRslt.TestDone = true;
|
|
}
|
|
}
|
|
}
|
|
else
|
|
{
|
|
///
|
|
/// Single meters
|
|
///
|
|
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
|
|
{
|
|
if (test.Part != 0 && test.Part != Utils.PartNr(i + 1, BatchRslts.Batch.Compound)) continue;
|
|
|
|
Results.Entities.MeterTestRslt meterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Single);
|
|
GenericDevices.IRegisterReader regReader = sensPath.RegisterReaders[i];
|
|
TestMethods.iPerlCommunication.iPerlHead.IperlHead iPerl = regReader as TestMethods.iPerlCommunication.iPerlHead.IperlHead;
|
|
GenericDevices.IRoi cameraRoi = regReader as GenericDevices.IRoi;
|
|
|
|
if (meterRslt != null && regReader != null)
|
|
{
|
|
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
|
|
meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses);
|
|
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
|
|
|
|
if (iPerl != null)
|
|
{
|
|
meterRslt.TimestampStart = iPerl.TimestampSecStart;
|
|
meterRslt.TimestampEnd = iPerl.NoSamples ? (iPerl.TimestampSecStart + tstRslt.TestTime) : iPerl.TimestampSecEnd;
|
|
meterRslt.TestTime = iPerl.NoSamples ? tstRslt.TestTime : (meterRslt.TimestampEnd - meterRslt.TimestampStart);
|
|
meterRslt.VolumeStart = iPerl.VolumeLtrStart; /// liter
|
|
meterRslt.VolumeEnd = iPerl.VolumeLtrEnd; /// liter
|
|
meterRslt.VolumeMeter = Math.Abs(iPerl.VolumeLtrEnd - iPerl.VolumeLtrStart);
|
|
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
|
|
iPerl.VolumeLtrRef = meterRslt.VolumeRef;
|
|
}
|
|
else if (cameraRoi != null)
|
|
{
|
|
meterRslt.TimestampStart = cameraRoi.TimestampStart; /// second
|
|
meterRslt.TimestampEnd = cameraRoi.TimestampEnd; /// second
|
|
meterRslt.TestTime = cameraRoi.TimestampEnd - cameraRoi.TimestampStart; /// second
|
|
|
|
meterRslt.VolumeStart = cameraRoi.VolumeStart; /// liter
|
|
meterRslt.VolumeEnd = cameraRoi.VolumeEnd; /// liter
|
|
meterRslt.VolumeMeter = cameraRoi.VolumeEnd - cameraRoi.VolumeStart; /// liter
|
|
|
|
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
|
|
}
|
|
else
|
|
{
|
|
meterRslt.TestTime = tstRslt.TestTime; /// TODO: Malo by sa citat z dosky
|
|
meterRslt.VolumeStart = 0;
|
|
meterRslt.VolumeEnd = 0;
|
|
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
|
|
meterRslt.VolumeRef = meterRslt.PulsesMaster * tstRslt.ConstMaster; /// liter
|
|
}
|
|
|
|
meterRslt.Error = Formulas.ErrorFromVolumes(meterRslt.VolumeMeter, meterRslt.VolumeRef);
|
|
meterRslt.Passed = (meterRslt.Error >= test.ErrLimLo + test.Uncertainty)
|
|
&& (meterRslt.Error <= test.ErrLimHi - test.Uncertainty);
|
|
meterRslt.TestDone = true;
|
|
tstRslt.TestDone = true;
|
|
|
|
if (iPerl != null)
|
|
{
|
|
iPerl.LastTestResult2 = iPerl.LastTestResult; /// Save shift previous test result
|
|
iPerl.LastTestResult = meterRslt; /// Save this test result
|
|
iPerl.NominalTestFlowLph = 500.0 * (test.Qfrom + test.Qto); /// Ave. + convert to liter/hour
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
tstRslt.Components = Results.Entities.Components
|
|
.UpdateList(BatchRslts.ComponentsList,
|
|
new Results.Entities.Components((BenchInfo != null) ? BenchInfo.TestBenchId : 1,
|
|
(BenchInfo != null) ? BenchInfo.TestBenchName : "testbench",
|
|
inPath.Pump != null ? inPath.Pump.Name : string.Empty,
|
|
outPath.FlowMeter != null ? outPath.FlowMeter.Name : string.Empty,
|
|
outPath.Scale != null ? outPath.Scale.Name : string.Empty,
|
|
outPath.RegulValve != null ? outPath.RegulValve.Name : string.Empty,
|
|
outPath.Diverter != null ? outPath.Diverter.Name : string.Empty));
|
|
|
|
/// Update results
|
|
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(testName, tstRslt));
|
|
}
|
|
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.TransitionAfter));
|
|
|
|
/// Append the results to the CSV-file
|
|
allResults.Info(TestResult2CsvLine(testName, test.Part));
|
|
|
|
if (!outerLoopMode && (++repetitionNr <= test.Repeats))
|
|
{
|
|
goto loop;
|
|
}
|
|
|
|
|
|
stopTest:
|
|
|
|
///----------------------///
|
|
/// Quit this sequence ///
|
|
///----------------------///
|
|
|
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
|
.AddOperation(checkUiOp)
|
|
.AddOperation(cBrd.StopPreviousOp())
|
|
.EnterState();
|
|
do
|
|
{
|
|
e = StateMachine.WaitRunDevsRunOps();
|
|
if (TestAndLogUiCmdStop(test, e)) { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
|
|
}
|
|
while (!e.Contains(Event.PreviousStopped));
|
|
|
|
/// Transition sequence at the end of test
|
|
/// Prevent overwriting 'retVal' in case it was set to non-default value earlier
|
|
switch (Transition(transitionAfter, (retVal == Event.Done) ? TransitionContext.AfterTest : TransitionContext.Stop))
|
|
{
|
|
case Event.Error: { if (retVal == Event.Done) retVal = Event.Error; break; }
|
|
case Event.UiCmdStop: { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
|
|
}
|
|
|
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr,
|
|
(retVal == Event.Done) ? Config.Entities.Progress.Completed : Config.Entities.Progress.Aborted));
|
|
|
|
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
|
IList<Event> retList = new List<Event>(1);
|
|
retList.Add(retVal);
|
|
return retList;
|
|
}
|
|
}
|
|
}
|