tbf/TestBenchFramework/BenchControl
2017-05-25 14:06:05 +02:00
..
Ambient MettlerToledo.all and Ambient.Comet : Fixed bugs in serial port handling when closing the program, ver. 2.12.467 2017-02-16 09:55:49 +01:00
BenchInfo IComponentCfg and IComponentFactory interfaces and all derived classes modified. 2016-08-05 14:32:36 +02:00
Configs/NameOnly Minor fixes, ver. 2.12.433 2016-12-29 12:29:37 +01:00
Danfoss/VLT2800 ulong --> UInt128 in all 'route' related variables, ver. 2.12.419 2016-12-12 17:39:12 +01:00
DataEntry 'X' button disabled on all DataEntry forms. 2017-04-28 13:04:09 +02:00
DB/SensusOracle DEWA Q2 correction modified, Results.Entities.WaterMeter columns added (iPerl only). 2017-03-31 14:17:18 +02:00
Dummy Draining modified, in BERLIN done always before flow setting, ver. 2.12.518 2017-03-28 23:54:52 +02:00
Elde PETERBURG_200 if/elif/endif-s fixed. 2017-05-16 13:14:44 +02:00
Generic DeviceTest program functional, runs operation Modbus.PressureMeter.Meret.ReadPressureOp(...) 2016-10-18 11:30:02 +02:00
GenericDevices Camera time read with each sample, calculation : VolumeStart, VolumeEnd, TimestampStart, TimestampEnd used, ver. 2.12.530 2017-04-07 11:29:35 +02:00
Keithley Keithley.Multimeter_2010_RS232.Multimeter shut-down bug fix, ver. 2.12.536 2017-04-10 15:06:56 +02:00
MettlerToledo TankDraining sequence conditions added (MettlerToledo scales). 2017-05-05 14:18:49 +02:00
Modbus ProcedureParams initialization/constructors modified. ProcedureParamsBase modified. 2017-05-01 16:03:45 +02:00
Network ProcedureParams initialization/constructors modified. ProcedureParamsBase modified. 2017-05-01 16:03:45 +02:00
Operations More CoverTest, avoid interference with DataEntry forms, 'bypass' logging. 2017-05-05 22:25:45 +02:00
Output On screen results use new style of configuration, part 2: ResultsConfigCtrl added. 2017-05-24 11:35:34 +02:00
ResultsPrinters Old style ResultsPrinters.Basic removed. 2017-05-19 11:25:44 +02:00
Sequences Q_ref_mean and many other result items added. 2017-05-19 11:25:24 +02:00
TestMethods tstRslt.FlowMin evaluated, saved to Oracle DB only. 2017-05-25 14:06:05 +02:00
WaterMeters ProcedureParams initialization/constructors modified. ProcedureParamsBase modified. 2017-05-01 16:03:45 +02:00
BenchPath.cs PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373 2016-10-18 19:14:01 +02:00
CfgChangeArgs.cs
CmdResponseArgs.cs
ComponentBase.cs
ComponentCfgBase.cs
Constants.cs
Current.cs
Events.cs 'Custom'/'Oprav DEWY' button added to BenchControlPanel, MainSeq changes 2017-04-12 17:59:48 +02:00
FeedingPath.cs IRegulValve change, regulation valves support Category, Category saved in settings, used in Feeding Paths UI, not used in tests yet, ver. 2.11.364 2016-10-12 15:47:45 +02:00
Formulas.cs Temperatures are internally stored and processed in double variables (except of ambient temp.). 2016-10-07 15:41:27 +02:00
HeatMetersPath.cs HeatMetersPath modifications, DB change. 2016-08-17 10:32:03 +02:00
IOperation.cs
MetersPath.cs Qfrom, Qto removed from MetersPath, ver. 2.9.326 2016-07-11 10:20:50 +02:00
OutputPath.cs Drain valve removed from Output path, outPath.Scale.DrainValve used instead of outPath.DrainValve, wait for Event. BalanceDone before 2nd mass measurement in FlyingStartMassCollection, ver. 2.12.519 2017-03-29 09:22:39 +02:00
ProcedureParamsBase.cs ProcedureParams initialization/constructors modified. ProcedureParamsBase modified. 2017-05-01 16:03:45 +02:00
State.cs Drain valves are specified as component parameters, tank draining on startup fixed, WaitTankEmptyOp, basic TankDraining management, etc, ver. 2.12.517 2017-03-28 12:50:09 +02:00
StateMachine.cs SLM_PT150, PETERBURG_50, PETERBURG_200 symbols, components added, ver. 2.13.557 2017-05-11 16:41:03 +02:00
TbfComponents.cs Old style ResultsPrinters.Basic removed. 2017-05-19 11:25:44 +02:00
TestBenchSim.cs Symbols: introduced IPERL, ORACLE_DB, HEAT_METERS, TURA_IPERL, TURA_SPECIAL 2017-02-14 13:42:22 +01:00
TestParamsBase.cs
Transition.cs