tbf/TestBenchFramework/BenchControl/TestMethods/FlyingStartMassCollection/FlyingStartMassCollectionSeq.cs
2017-07-14 17:13:07 +02:00

1031 lines
51 KiB
C#

///
/// Copyright (c) 2013-2017 Sensus Metering Systems
///
using System;
using System.Collections.Generic;
using System.Text;
using log4net;
using TBF.BenchControl;
using TBF.Boxes;
using TBF.Resources;
using TBF.UiBridge;
namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
{
public class FlyingStartMassCollectionSeq : Sequences.SequenceBase
{
private static readonly ILog log = LogManager.GetLogger(typeof(FlyingStartMassCollectionSeq));
/// <summary>
/// Flying start mass collection method sequence
/// </summary>
/// <param name="test">Test entity</param>
/// <returns>
/// Event.Done . . . . . . . OK
/// Event.UiCmdStop . . . . Stopped by the user using the on-screen button STOP
/// Event.OpArgumentError . Target flow is out of range
/// Event.Error . . . . . . Unspecified error
/// </returns>
public IList<Event> Execute(Config.Entities.Test test, bool outerLoopMode, int outerLoopCounter,
Compound.CombinedTestParams compoundTestParams,
HeatMeters.TestParams heatMetersTestParams,
Config.Entities.DebugMode debugLevel)
{
IList<Event> e = new List<Event>(); /// Events from currently running operations
Event retVal = Event.Done;
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
if (debugLevel == Config.Entities.DebugMode.Simulate)
{
///
/// Test method simulation
///
TestProgressEventArgs.SetEstimatedTimes(new int[] { 0, 0, 0, 30, 0, 30, 0, 0 } );
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, Config.Entities.Progress.JustStarted));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, Config.Entities.Progress.FlowSetting));
if (compoundTestParams != null)
{
if (test.Name.ToLower().Contains("nok")) MakeSimulatedCompound(test.Name, 1, 1, 0, 4.7f, 0.9f);
else MakeSimulatedCompound(test.Name, 1, 1, 0, 0.7f, 1.0f);
}
else if (heatMetersTestParams != null)
{
MakeSimulatedHeatMeters(test.Name, 1, 1, 0, 1.5f, 1000000, heatMetersTestParams.ErrorLimitLo, heatMetersTestParams.ErrorLimitHi, heatMetersTestParams.EvaluateVolume);
}
else
{
float errorPctBase = -1.0f;
if (test.Name.ToLower().Contains("q3")) errorPctBase = -0.5f;
else if (test.Name.ToLower().Contains("q2")) errorPctBase = 0.5f;
else if (test.Name.ToLower().Contains("q1")) errorPctBase = -5.1f;
if (outerLoopMode)
{
MakeSimulated(test.Name, test.Repeats, outerLoopCounter, 0, errorPctBase + outerLoopCounter * 0.1f);
}
else
{
for (int i = 1; i <= test.Repeats; i++) MakeSimulated(test.Name, test.Repeats, i, 0, i * 0.1f);
}
}
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, Config.Entities.Progress.Completed));
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(test.Name, BatchRslts.GetTestRslt(Results.Utils.GetTestName(test.Name, 1, 1), 0)));
allResults.Info(TestResult2CsvLine(test.Name, 0)); /// Append the results to the CSV-file
for (int i = 0; i < Config.Data.WMsCount; i++)
{
TestMethods.iPerlCommunication.iPerlHead.IperlHead iPerl = ((sensPath.RegisterReaders != null) && (i < sensPath.RegisterReaders.Length))
? (sensPath.RegisterReaders[i] as TestMethods.iPerlCommunication.iPerlHead.IperlHead)
: null;
if (iPerl != null)
{
/// TODO: Reimplement
//iPerl.LastTestResult = meterRslt; /// Save this water meter test result to iPerl WM
iPerl.NominalTestFlowLph = 500.0 * (double)(test.Qfrom + test.Qto); /// Ave. + convert to liter/hour
}
}
//------------------------------------------------
Bridge.OnActivity(this, string.Format("{0} Simulation", test.Name));
//------------------------------------------------
State.Create(string.Format("{0}({1}) : Simulation", test.Method, test.Name))
.AddOperation(checkUiOp)
.EnterState();
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) retVal = Event.UiCmdStop;
/// Create a list with one item 'retVal' (default is Event.Done) and return it
IList<Event> retListSim = new List<Event>(1);
retListSim.Add(retVal);
return retListSim;
}
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse;
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
int repetitionNr = outerLoopMode ? outerLoopCounter : 1; /// First test: repetitionNr = 1
if (test.Volume > outPath.Scale.Capacity * Constants.TankFullFactor)
{
Bridge.OnError(this, Strings.Test_volume_exceeds_the_scale_capacity);
retVal = Event.UiCmdStop;
goto stopTestWOTransitionAfter;
}
//====================================
// Transition or SetRoute - Start
//====================================
switch (Transition(transitionBefore, TransitionContext.BeforeTest))
{
case Event.Error: { retVal = Event.Error; goto stopTest; }
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
}
//====================================
loop:
/// Start the test, initialize test results
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
TestStartTime = DateTime.Now;
TestProgressEventArgs.SetEstimatedTimes(new int[] { 1, 1, 1, 30, 0, Convert.ToInt32(test.TstTime) + 15, 0, 0 }); /// start, transition, flow detection, flow setting, aborted, test, transition, end
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
//------------------------------------------------
Bridge.OnActivity(this, Strings.Checking_tank_capacity);
//------------------------------------------------
bool drainTheTank = test.DoDraining;
if (!drainTheTank) /// If condition met => skip measuring and force emptying
{
///
/// Measure the weight and skip emptying if there is enough room in the tank
///
State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(outPath.Scale.ReadMassOp(ref Mass))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.BalanceDone));
double estimatedEndMass = Mass.Val + test.Volume;
if (estimatedEndMass >= outPath.Scale.Capacity * Constants.TankFullFactor)
{
drainTheTank = true;
}
}
///
if (drainTheTank)
{
#if BERLIN
switch (DrainTheTank(outPath.Scale.DrainValve, outPath.Scale))
{
case Event.Error: { retVal = Event.Error; goto stopTest; }
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
}
drainTheTank = false;
#else
State.Create(string.Format("{0}({1}) : Opening the emptying valve", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.SetValvesOp(outPath.Scale.DrainValve, null))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.ValvesSet));
#endif
}
///
/// Optionally display prompt to emerge temperature meters to appropriate baths for heat meters test
///
IOperation heatMetersPromptOp = null;
if (heatMetersTestParams != null && !string.IsNullOrEmpty(heatMetersTestParams.Prompt))
{
/// Make sure the CycleBeginForm is closed
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
heatMetersPromptOp = new Operations.MessageBoxOp(heatMetersTestParams.Prompt);
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Starting_the_pump);
//------------------------------------------------
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
int flowSetTime0 = StateMachine.Time;
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
///
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
.AddOperation(heatMetersPromptOp)
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
}
while (e.Contains(Event.ValvesBusy) /* || !e.Contains(Event.AllPositionsReached)*/);
if (test.TimePump2StartV > 0)
{
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.TimerExpired));
}
if (benchPath.StopBFValve != null)
{
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
}
while (!e.Contains(Event.ValvesSet));
}
if (test.TimeBeforeFlow > 0)
{
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.TimerExpired));
}
setting_flow:
//------------------------------------------------
Bridge.OnActivity(this, Strings.Setting_the_flow);
//------------------------------------------------
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, 990)) /// timeout = 16.5 min.
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.RegulValveTimeOut))
{
Bridge.OnError(this, Strings.Timeout);
retVal = Event.Done;
goto stopTest;
}
if (e.Contains(Event.Next)) goto flow_set;
}
while (!e.Contains(Event.FlowReached));
flow_set:
int flowSetTime = StateMachine.Time - flowSetTime0;
double currentFlow = RefFlow.Val;
if (heatMetersTestParams != null && heatMetersPath != null)
{
//---------------------------------------------------
Bridge.OnActivity(this, Strings.Setting_temperature);
//---------------------------------------------------
int lastTimeSec = StateMachine.Time;
double Tw_last = 0;
double Tc_last = 0;
State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.Next)) goto temperature_set;
if (TempRefHi1.Val != 0 && TempRefHi2.Val != 0 && TempRefLo1.Val != 0 && TempRefLo2.Val != 0)
{
if (StateMachine.Time - lastTimeSec > 10 || StateMachine.Time - lastTimeSec < 0)
{
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
if (heatMetersTestParams.TempWarmLo <= Tw && Tw <= heatMetersTestParams.TempWarmHi &&
heatMetersTestParams.TempColdLo <= Tc && Tc <= heatMetersTestParams.TempColdHi &&
Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm &&
Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold &&
Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm &&
Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold)
{
goto temperature_set;
}
lastTimeSec = StateMachine.Time;
Tw_last = Tw;
Tc_last = Tc;
}
}
}
while (true);
}
else if (test.DoControlWaterTemp && benchPath.TempMtrUp != null && benchPath.TempMtrDown != null)
{
//---------------------------------------------------
Bridge.OnActivity(this, Strings.Setting_temperature);
//---------------------------------------------------
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.Next)) goto temperature_set;
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
{
goto temperature_set;
}
}
while (true);
}
temperature_set:
///
/// Prepare cameras, ROI-s and measurementOperations
///
/// Find successfully detected ROI-s
IList<GenericDevices.IRoi> rois = new List<GenericDevices.IRoi>();
foreach (var rr in sensPath.RegisterReaders)
{
GenericDevices.IRoi roi = rr as GenericDevices.IRoi;
if (roi != null && roi.Detected)
{
rois.Add(roi);
}
}
/// Find cameras
IList<GenericDevices.ICamera> cameras = new List<GenericDevices.ICamera>();
foreach (var roi in rois)
{
if (roi.Camera != null && !cameras.Contains(roi.Camera))
{
cameras.Add(roi.Camera);
roi.Camera.ClearRoiParams();
}
}
/// Register ROI-parameters to cameras
foreach (var roi in rois) roi.RegisterRoiToCamera();
/// Prepare measurementOperations
IList<IOperation> measureOperations = new List<IOperation>();
foreach (var camera in cameras) measureOperations.Add(camera.MeasurementOp());
if (drainTheTank)
{
//------------------------------------------------
Bridge.OnActivity(this, Strings.Closing_the_tank);
//------------------------------------------------
///
/// Make sure tank emptying completed
///
IList<IOperation> extraOps = new List<IOperation>();
if (heatMetersPath != null)
{
extraOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
extraOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
extraOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
extraOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
}
switch (DrainTheTank(outPath.Scale.DrainValve, outPath.Scale, extraOps))
{
case Event.Error: { retVal = Event.Error; goto stopTest; }
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
}
drainTheTank = false;
}
if (test.TimeFlow2Mass > 0)
{
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.TimerExpired));
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Measuring_the_weight);
//------------------------------------------------
LogProcessDataTestInfo(processDataLogger, test.Procedure.Name, test.Name);
if (heatMetersPath == null) LogProcessDataHeader(processDataLogger, "Start mass");
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(measureOperations)
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperation(outPath.Scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(processDataLoggingOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.BalanceDone));
log.WarnFormat("Start mass = {0}kg", StartMass);
Mass.Val = StartMass.Val;
if (heatMetersPath == null) LogProcessDataHeader(processDataLogger, "Measurement");
else LogProcessDataHeaderHeatMeters(processDataLogger, "Measurement");
//------------------------------------------------
Bridge.OnActivity(this, Strings.Test_in_progress);
//------------------------------------------------
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(measureOperations)
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(processDataLoggingOp)
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
test.Qfrom, test.Qto, totalPulses, (float)test.TolerRed))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.MeasurementStarted));
foreach (var rr in sensPath.RegisterReaders)
{
if (rr is TestMethods.iPerlCommunication.iPerlHead.IperlHead)
{
(rr as TestMethods.iPerlCommunication.iPerlHead.IperlHead).TestName = test.Name;
}
}
/// Measurement loop - preparation
readRegistersOp = new Operations.ReadMoreRegistersOp(sensPath.RegisterReaders);
int estimtdEndTime = StateMachine.Time + (int)test.TstTime;
ClearAllStatistics(StateMachine.Time);
/// Measurement loop - begin
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(measureOperations)
.AddOperation(readRegistersOp)
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(outPath.Scale.ReadMassOp(ref Mass))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
: null)
.AddOperation(cBrd.QueryMeasurementEndOp())
.AddOperation(processDataLoggingOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
if (e.Contains(Event.MeasurementCompleted)) goto test_completed;
//------------------------------------------------
int remainingTime = Math.Max(estimtdEndTime - StateMachine.Time, 0);
if (remainingTime > 60)
{
Bridge.OnActivity(this, string.Format("{0} ... {1} {2} {3} {4}", Strings.Test_in_progress, remainingTime / 60, "min", remainingTime % 60, Strings.sec));
}
else
{
Bridge.OnActivity(this, string.Format("{0} ... {1} s", Strings.Test_in_progress, remainingTime));
}
//------------------------------------------------
RefFreq.Val = cBrd.ReferenceFreq;
RefFlow.Val = cBrd.ReferenceFlow;
UpdateAllStatistics(StateMachine.Time);
if (heatMetersTestParams != null)
{
if (lastEnergyUpdateTime == 0)
{
lastEnergyUpdateTime = StateMachine.Time;
}
else
{
//double deltaTime = (double)(StateMachine.Time - lastEnergyUpdateTime);
double T_in = (TempRefHi1.Val + TempRefHi2.Val) / 2; /// [°C]
double T_out = (TempRefLo1.Val + TempRefLo2.Val) / 2; /// [°C]
double deltaVolume = LtrPerRefPulse * RefPulsesDelta; /// [l]
double deltaEnergy = (0.001 * deltaVolume) * (T_in - T_out) * Formulas.HeatCoefficientWater(16, T_in, T_out, heatMetersTestParams.FlowMeasuredAtHiTempPipe); /// [J] = [m3] * [K] * [J/(m3 K)]
Energy.Update(deltaEnergy);
VolumeForEnergy.Update(deltaVolume);
lastEnergyUpdateTime = StateMachine.Time;
}
}
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
}
while (!e.Contains(Event.Next)); /// 'Next' button can be used in Debug version
/// Measurement loop - end
test_completed:
///
/// Water is stopped immediately after the test and before the 2nd mass measurement in case;
/// - no 'transition sequence after test' is used
/// - this is the last (or the only) test repetition or test is a part of an 'outer loop'
///
if (transitionAfter == null && (outerLoopMode || repetitionNr == test.Repeats))
{
switch (Transition(transitionAfter, TransitionContext.AfterTest))
{
case Event.Error: { retVal = Event.Error; goto stopTest; }
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
}
}
//------------------------------------------------
Bridge.OnActivity(this, Strings.Measuring_the_weight);
//------------------------------------------------
State.Create(string.Format("{0}({1}) : Waiting before the 2nd mass measurement", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperation(outPath.Scale.ReadMassOp(ref Mass))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(processDataLoggingOp)
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.TimerExpired) || !e.Contains(Event.BalanceDone));
if (heatMetersPath == null) LogProcessDataHeader(processDataLogger, "End mass");
else LogProcessDataHeaderHeatMeters(processDataLogger, "End mass");
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperation(outPath.Scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(processDataLoggingOp)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.BalanceDone));
///
log.WarnFormat("End mass = {0}kg", EndMass);
TestEndTime = DateTime.Now;
//------------------------------------------------
Bridge.OnActivity(this, Strings.Test_completed);
//------------------------------------------------
/// Make sure the CycleBeginForm is closed so that water meter data (s/n) can be copied into results
if (heatMetersPromptOp == null)
{
if (UIFlowControl.Stop == WaitBeginFormClosed()) goto stopTest;
}
///
/// Populate TestResult data entity with data
///
Results.Entities.TestRslt tstRslt = BatchRslts.GetTestRslt(testName, test.Part);
if (tstRslt != null)
{
UpdateTempPressDensAmb(tstRslt);
/// Main results
tstRslt.StartTime = TestStartTime;
tstRslt.EndTime = TestEndTime;
tstRslt.FlowSetTime = flowSetTime;
tstRslt.TestTime = cBrd.TTime; /// [s] measurement time
tstRslt.PulsesMaster = Convert.ToDouble(cBrd.EtPulses(0)); /// Pulses of the master flow meter (test total)
tstRslt.MassStartRaw = StartMass.Val;
tstRslt.MassStart = Formulas.CorrectedValue(tstRslt.MassStartRaw, outPath.Scale.Corrections);
tstRslt.MassEndRaw = EndMass.Val;
tstRslt.MassEnd = Formulas.CorrectedValue(tstRslt.MassEndRaw, outPath.Scale.Corrections);
tstRslt.FlowMass = 3600.0 * (tstRslt.MassEnd - tstRslt.MassStart) / tstRslt.TestTime; /// [kg/h]
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
tstRslt.Buoyancy = TBF.BenchControl.Formulas.Buoyancy();
tstRslt.VolumeCTV = tstRslt.Buoyancy * (tstRslt.MassEnd - tstRslt.MassStart) / tstRslt.DensityOut; /// [l] 1000.0f is because density is in [kg/m3]
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
tstRslt.ConstMaster = LtrPerRefPulse * tstRslt.VolumeCTV / tstRslt.VolumeMaster; /// Corrected master pulses per liter
tstRslt.ErrorMaster = Formulas.ErrorFromVolumes(tstRslt.VolumeMaster, tstRslt.VolumeCTV);
tstRslt.FlowMean = (float)RefFlowStat.Average;
tstRslt.FlowMin = (float)RefFlowStat.Min;
tstRslt.FlowMax = (float)RefFlowStat.Max;
if (compoundTestParams != null)
{
///
/// Compound meters
///
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
{
if (test.Part != 0 && test.Part != Utils.PartNr(i + 1, BatchRslts.Batch.Compound)) continue;
Results.Entities.MeterTestRslt mainMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.CompoundMain);
Results.Entities.MeterTestRslt auxMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.CompoundAux);
for (int isAux = 0; isAux <= 1; isAux++) /// 0=main, 1=aux
{
GenericDevices.IRegisterReader regReader = sensPath.RegisterReaders[2 * i + isAux];
Results.Entities.MeterTestRslt meterRslt = (isAux == 0) ? mainMeterRslt : auxMeterRslt;
if (meterRslt != null && regReader != null)
{
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
/// Optionally supress pulses from the large water meter
meterRslt.PulsesMeter = (isAux == 0 && compoundTestParams.SupressTrills) ? 0 : Convert.ToDouble(regReader.WMPulses);
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
meterRslt.TestTime = tstRslt.TestTime;
meterRslt.VolumeStart = 0;
meterRslt.VolumeEnd = 0;
meterRslt.VolumeRef = tstRslt.VolumeCTV;
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
if (meterRslt.PulsesMaster != 0)
{
meterRslt.VolumeMeter *= (tstRslt.PulsesMaster / meterRslt.PulsesMaster);
}
meterRslt.Error = Formulas.ErrorFromVolumes(meterRslt.VolumeMeter, tstRslt.VolumeCTV); /// Main/Aux meter error is not usedfor evaluation
}
}
Results.Entities.MeterTestRslt compoundMeterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Compound);
if (compoundMeterRslt != null && mainMeterRslt != null && auxMeterRslt != null)
{
compoundMeterRslt.VolumeRef = tstRslt.VolumeCTV;
compoundMeterRslt.VolumeMeter = mainMeterRslt.VolumeMeter + auxMeterRslt.VolumeMeter;
compoundMeterRslt.PulsesMaster = tstRslt.PulsesMaster;
compoundMeterRslt.TestTime = tstRslt.TestTime;
compoundMeterRslt.Error = Formulas.ErrorFromVolumes(compoundMeterRslt.VolumeMeter, compoundMeterRslt.VolumeRef);
compoundMeterRslt.Passed = (compoundMeterRslt.Error >= test.ErrLimLo + test.Uncertainty)
&& (compoundMeterRslt.Error <= test.ErrLimHi - test.Uncertainty);
mainMeterRslt.Passed = auxMeterRslt.Passed = compoundMeterRslt.Passed;
mainMeterRslt.TestDone = auxMeterRslt.TestDone = compoundMeterRslt.TestDone = true;
tstRslt.TestDone = true;
}
}
}
else if (heatMetersTestParams != null)
{
///
/// Heat meters
///
tstRslt.RefEnergy = Energy.Sum * tstRslt.VolumeCTV / VolumeForEnergy.Sum; /// [J] = [J] * [l] / [l]
tstRslt.Custom1 = (float)TempRefHiStat.Average;
tstRslt.Custom2 = (float)TempRefHiStat.First;
tstRslt.Custom3 = (float)TempRefHiStat.Last;
tstRslt.Custom4 = (float)TempRefHiStat.Min;
tstRslt.Custom5 = (float)TempRefHiStat.Max;
tstRslt.Custom6 = (float)TempRefLoStat.Average;
tstRslt.Custom7 = (float)TempRefLoStat.First;
tstRslt.Custom8 = (float)TempRefLoStat.Last;
tstRslt.Custom9 = (float)TempRefLoStat.Min;
tstRslt.Custom10 = (float)TempRefLoStat.Max;
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
{
if (test.Part != 0 && test.Part != Utils.PartNr(i + 1, BatchRslts.Batch.Compound)) continue;
Results.Entities.MeterTestRslt volumeRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterVolume);
Results.Entities.MeterTestRslt energyRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterEnergy);
BenchControl.GenericDevices.IRegisterReader volumeRegReader =
(sensPath.RegisterReaders.Length > 2 * i) ? sensPath.RegisterReaders[2 * i] : null;
BenchControl.GenericDevices.IRegisterReader energyRegReader =
(sensPath.RegisterReaders.Length > 2 * i + 1) ? sensPath.RegisterReaders[2 * i + 1] : null;
if (volumeRslt != null && volumeRegReader != null)
{
volumeRslt.PulsesPerLiter = volumeRegReader.PulsesPerLtr; /// [l ^ -1]
volumeRslt.PulsesMeter = Convert.ToDouble(volumeRegReader.WMPulses);
volumeRslt.PulsesMaster = Convert.ToDouble(volumeRegReader.WMRefPulses);
volumeRslt.VolumeStart = 0;
volumeRslt.VolumeEnd = 0;
volumeRslt.VolumeMeter = volumeRslt.PulsesMeter * volumeRegReader.LtrsPerPulse; /// [l]
volumeRslt.VolumeRef = volumeRslt.PulsesMaster * tstRslt.ConstMaster; /// [l]
volumeRslt.TestTime = tstRslt.TestTime; /// [s]
volumeRslt.Error = Formulas.ErrorFromVolumes(volumeRslt.VolumeMeter, volumeRslt.VolumeRef);
volumeRslt.Passed = !heatMetersTestParams.EvaluateVolume ||
((volumeRslt.Error >= test.ErrLimLo + test.Uncertainty) &&
(volumeRslt.Error <= test.ErrLimHi - test.Uncertainty));
volumeRslt.TestDone = true;
tstRslt.TestDone = true;
}
if (energyRslt != null && energyRegReader != null)
{
energyRslt.PulsesPerLiter = energyRegReader.PulsesPerLtr; /// [kWh ^ -1]
energyRslt.PulsesMeter = Convert.ToDouble(energyRegReader.WMPulses);
energyRslt.PulsesMaster = Convert.ToDouble(energyRegReader.WMRefPulses);
energyRslt.VolumeStart = 0;
energyRslt.VolumeEnd = 0;
energyRslt.VolumeRef = tstRslt.RefEnergy * (energyRslt.PulsesMaster / tstRslt.PulsesMaster); /// [J]
energyRslt.VolumeMeter = energyRslt.PulsesMeter * Config.Units.ConvertFrom(Config.Unit.kWh, energyRegReader.LtrsPerPulse); /// [J]
energyRslt.TestTime = tstRslt.TestTime; /// [s]
energyRslt.Error = Formulas.ErrorFromVolumes(energyRslt.VolumeMeter, energyRslt.VolumeRef);
energyRslt.Passed = (energyRslt.Error >= heatMetersTestParams.ErrorLimitLo)
&& (energyRslt.Error <= heatMetersTestParams.ErrorLimitHi);
energyRslt.TestDone = true;
tstRslt.TestDone = true;
}
}
}
else
{
///
/// Single meters
///
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
{
if (test.Part != 0 && test.Part != Utils.PartNr(i + 1, BatchRslts.Batch.Compound)) continue;
/// MetersKind.Single meters
Results.Entities.MeterTestRslt meterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Single);
GenericDevices.IRegisterReader regReader = sensPath.RegisterReaders[i];
TestMethods.iPerlCommunication.iPerlHead.IperlHead iPerl = regReader as TestMethods.iPerlCommunication.iPerlHead.IperlHead;
GenericDevices.IRoi cameraRoi = regReader as GenericDevices.IRoi;
if (meterRslt != null && regReader != null)
{
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses);
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
if (iPerl != null)
{
meterRslt.TimestampStart = iPerl.TimestampSecStart;
meterRslt.TimestampEnd = iPerl.NoSamples ? (iPerl.TimestampSecStart + tstRslt.TestTime) : iPerl.TimestampSecEnd;
meterRslt.TestTime = iPerl.NoSamples ? tstRslt.TestTime : (meterRslt.TimestampEnd - meterRslt.TimestampStart);
meterRslt.VolumeStart = iPerl.VolumeLtrStart; /// liter
meterRslt.VolumeEnd = iPerl.VolumeLtrEnd; /// liter
meterRslt.VolumeMeter = Math.Abs(iPerl.VolumeLtrEnd - iPerl.VolumeLtrStart);
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
iPerl.VolumeLtrRef = meterRslt.VolumeRef;
#if IPERL
meterRslt.WaterMeter.CalibFactor = (iPerl.CalibrationStruct != null) ? iPerl.CalibrationStruct.Calibration : 0;
meterRslt.WaterMeter.Q2Correction = iPerl.Q2Correction;
meterRslt.WaterMeter.Q2CorrRFlow = iPerl.Q2CorrRFlow;
meterRslt.WaterMeter.Q2CorrLFlow = iPerl.Q2CorrLFlow;
#endif
iPerl.LastTestResult2 = iPerl.LastTestResult; /// Save shift previous test result
iPerl.LastTestResult = meterRslt; /// Save this test result
iPerl.NominalTestFlow = 500.0 * (test.Qfrom + test.Qto); /// Ave. + convert to liter/hour
}
else if (cameraRoi != null)
{
meterRslt.TimestampStart = cameraRoi.TimestampStart; /// second
meterRslt.TimestampEnd = cameraRoi.TimestampEnd; /// second
meterRslt.TestTime = cameraRoi.TimestampEnd - cameraRoi.TimestampStart; /// second
meterRslt.VolumeStart = cameraRoi.VolumeStart; /// liter
meterRslt.VolumeEnd = cameraRoi.VolumeEnd; /// liter
meterRslt.VolumeMeter = cameraRoi.VolumeEnd - cameraRoi.VolumeStart; /// liter
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
}
else
{
meterRslt.TestTime = tstRslt.TestTime; /// TODO: Malo by sa citat z dosky
meterRslt.VolumeStart = 0; /// liter
meterRslt.VolumeEnd = 0; /// liter
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
meterRslt.VolumeRef = meterRslt.PulsesMaster * tstRslt.ConstMaster; /// liter
}
meterRslt.Error = Formulas.ErrorFromVolumes(meterRslt.VolumeMeter, meterRslt.VolumeRef);
meterRslt.Passed = (meterRslt.Error >= test.ErrLimLo + test.Uncertainty)
&& (meterRslt.Error <= test.ErrLimHi - test.Uncertainty);
meterRslt.TestDone = true;
tstRslt.TestDone = true;
}
}
}
tstRslt.Components = Results.Entities.Components.UpdateList(BatchRslts.ComponentsList,
new Results.Entities.Components((BenchInfo != null) ? BenchInfo.TestBenchId : 1,
(BenchInfo != null) ? BenchInfo.TestBenchName : "testbench",
inPath.Pump != null ? inPath.Pump.Name : string.Empty,
outPath.FlowMeter != null ? outPath.FlowMeter.Name : string.Empty,
outPath.Scale != null ? outPath.Scale.Name : string.Empty,
outPath.RegulValve != null ? outPath.RegulValve.Name : string.Empty,
outPath.Diverter != null ? outPath.Diverter.Name : string.Empty));
/// Update results
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(testName, tstRslt));
}
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.TransitionAfter));
/// Append the results to the CSV-file
allResults.Info(TestResult2CsvLine(testName, test.Part));
if (!outerLoopMode && (++repetitionNr <= test.Repeats))
{
goto loop;
}
stopTest:
///----------------------///
/// Quit this sequence ///
///----------------------///
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(cBrd.StopPreviousOp())
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.PreviousStopped));
/// Transition sequence at the end of test
/// Prevent overwriting 'retVal' in case it was set to non-default value earlier
switch (Transition(transitionAfter, (retVal == Event.Done) ? TransitionContext.AfterTest : TransitionContext.Stop))
{
case Event.Error: { if (retVal == Event.Done) retVal = Event.Error; break; }
case Event.UiCmdStop: { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
}
stopTestWOTransitionAfter:
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr,
(retVal == Event.Done) ? Config.Entities.Progress.Completed : Config.Entities.Progress.Aborted));
/// Create a list with one item 'retVal' (default is Event.Done) and return it
IList<Event> retList = new List<Event>(1);
retList.Add(retVal);
return retList;
}
}
}