Files
tbf/TBF/Rig/RegisterReaders/GenesisRegReader/implementations/Enums.cs
T
michal 7e3df77b5b Refactor GenesisSmartReader processing logic and tests for robust handling:
- Replace property getters with concise expressions in `GenesisSmartReader`.
- Implement FIFO and concurrent producer-consumer unit tests for `ProcessingLoop`.
- Add startup flush mechanism for improved input handling on initialization.
- Refactor processing loop with structured start/stop tasks and cancellation tokens.
- Fix thread-safety issues and enhance logic in `Stop` and `StopDataStreamProcessing`.
- Add internal visibility for tests in `TBFTests` via `InternalsVisibleTo`.
- Update assembly version to `3.9.3038.1`.
2026-04-07 10:42:27 +02:00

122 lines
3.2 KiB
C#

///
/// Copyright (c) 2015-2017 Sensus Metering Systems
///
using System.ComponentModel;
namespace TBF.Rig.RegisterReaders.GenesisRegReader.implementations
{
public enum MessageID
{
Calibration = 0x00, /// Access to stCalibration
Configuration = 0x01, /// Access to stConfig
Status = 0x02, /// Access to stStaus, read only
Power = 0x03, /// Access to stPower, containing power info from both processors
LCD = 0x04, /// Access to stLCD
EventData = 0x05, /// NOT USED
IntervalData = 0x06, /// NOT USED
Diagnostics = 0x07, /// Access tostMetroDiagArray, read onl
MetrologyMemory = 0x08, /// Memory block access, read only
Error_LongAck = 0x09, /// Error message
Command = 0x0A, /// Command to execute, with no arguments
Parameterizing = 0x0B, /// Parameterizing message is used in MCI-SPI interface only
Error_ShortAck = 0x0C, /// Short acknowledge message is used in MCI-SPI interface only
ChanelAlive = 0x0D, /// Channel alive message is used in MCI-SPI interface only
RadioPassthrough = 0x0E, /// RFID <-> Metrology <-> Radio passthrough message
ASICRegisterReadTest = 0x0F, /// ASIC Register read test
IMIDebugMessagesAccess = 0x10, /// IMI debug messages read test
ProductionChecksumsRead = 0x11, /// Production checksum read: Calibration (1 byte), Configuration (2 bytes), spare (4 bytes)
HardwareParametersTest = 0x12, /// Hardware Parameters Testing: User configurable fixed field drive time (1 byte)
/// <summary>
/// Notes:
/// 1. Short Ack message contains 1-byte error code and all the fields (Offset, Payload length, payload and password) will not be present.
/// 2. Channel Alive message does not contain the fields (Offset, Payload length, payload and password).
/// 3. Except the above two special messages, rest all the messages in the above table will follow the message format mentioned in sections 3.1 and 3.2.
/// </summary>
Count /// Number of MessageID-s
}
public enum MeterType : byte
{
DN15 = 0,
CoaxManifold = 1,
DN20 = 2,
DN25 = 3,
DN26 = 4, /// DN25*
DN32 = 5,
DN40 = 6,
AutoDetect,
Count /// Number of meter types
}
public enum VolumeUnits : byte
{
m3 = 0,
UK_gallon = 1,
US_gallon = 2,
Count /// Number of volume units
}
public enum FlowArrow : byte
{
No = 0,
Right = 1,
Left = 2,
Count /// Number of flow arrows
}
public enum MeterSealed : byte
{
InProduction = 0x00,
OutOfProduction = 0xA5,
Sealed = 0x5A,
}
public enum MeterState : byte
{
None = 0,
Idle = 1,
Active = 2,
Test = 3,
EndOfLife = 4,
Count /// Number of meter states
}
public enum FlowState : byte
{
No = 0,
Reverse = 1,
Forward = 2,
EmptyPipe = 3,
Count /// Number of flow states
}
// public enum OptoTelegramFlags : byte
// {
// OK = 0,
// OK_TestStart,
// OK_TestEnd,
// InvalidTelegram, /// Wrong telegram format of checksum error
// SyncError,
// }
public enum OptoState
{
Read,
Flush,
}
public enum DataStreamState
{
Flush = 0,
ProcessAndSave,
CalculateStoredData,
}
public enum CommunicationInterface
{
[Description("RFID")]RFID,
[Description("NFC")]NFC
}
}