tbf/TestBenchFramework/BenchControl
2017-09-28 17:11:41 +02:00
..
Ambient XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
BenchInfo XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
Configs/NameOnly XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
Danfoss/VLT2800 XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
DataEntry Bug fixes in FixedStartMassCollectionSeq, cosmetical changes in DataEntry.StandardCamera, ver. 2.15.634 2017-07-28 17:21:30 +03:00
DB/SensusOracle (1) LU-logging changes, (2) Oracle DB changes for Greece - saving average results from multiple tests. 2017-07-14 16:31:05 +02:00
Dummy All scales support GetSerNumOp (however some return null). Reading S/N of all scales on program startup, ver. 2.14.588 2017-06-26 13:22:36 +02:00
Elde Measurement of valve open/close time required for E11, E12 evaluation. DiverterStart/DiverterEnd is float in sec., ver. 2.17.677 2017-09-28 12:54:16 +02:00
Generic DeviceTest program functional, runs operation Modbus.PressureMeter.Meret.ReadPressureOp(...) 2016-10-18 11:30:02 +02:00
GenericDevices Measurement of valve open/close time required for E11, E12 evaluation. DiverterStart/DiverterEnd is float in sec., ver. 2.17.677 2017-09-28 12:54:16 +02:00
Keithley XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
MettlerToledo Draining can be stopped by drain buttons, not by STOP button. 2017-07-19 16:38:46 +03:00
Modbus Modbus.CometAmbient component implemented (Comet and Easytherms are connected to the same Modbus), ver. 2.17.678 2017-09-28 15:24:10 +02:00
Network Network.Camera.Display extended to 12 images. 2017-09-28 00:07:42 +02:00
Operations BenchControlPanel supports Drain buttons highlighting (3 states). 2017-07-19 08:00:51 +02:00
Output (1) Zapiska bottom columns fixed, (2) unused WM-s disabled after reloading results, (3) Passed_seals_count, Diverter_start/end_time added, ver. 2.17.675 2017-09-28 09:39:58 +02:00
ResultsPrinters XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
Sequences (1) Zapiska bottom columns fixed, (2) unused WM-s disabled after reloading results, (3) Passed_seals_count, Diverter_start/end_time added, ver. 2.17.675 2017-09-28 09:39:58 +02:00
TestMethods Diverter and start/stop valve switch time logging in ms, ver. 2.17.679 2017-09-28 17:11:41 +02:00
Various/ErrorFlags Measurement of valve open/close time required for E11, E12 evaluation. DiverterStart/DiverterEnd is float in sec., ver. 2.17.677 2017-09-28 12:54:16 +02:00
WaterMeters Something 2017-07-14 17:13:01 +02:00
BenchPath.cs PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373 2016-10-18 19:14:01 +02:00
CfgChangeArgs.cs Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
CmdResponseArgs.cs Config change handler for Diverter, it should be possible to calibrate the analog input. 2015-06-12 16:39:57 +02:00
ComponentBase.cs 'Config', 'Results' projects added, includes iPerl opto logging bug-fixes, builds OK, cannot open DB, version 2.0.158. 2015-12-05 14:18:36 +01:00
ComponentCfgBase.cs XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
Constants.cs (1) TankFullFactor -> 0.95, (2) bit80 calculation for PETERSBURG_200, ver. 2.15.626 2017-07-25 10:06:31 +03:00
Events.cs ErrorFlags component added, Results.Entities.TestRslt upgraded to DB v.2.16, ErrorFlags and ErrorFlagsMd added, used in test methods, ver. 2.16.642 2017-08-20 09:54:42 +02:00
FeedingPath.cs IRegulValve change, regulation valves support Category, Category saved in settings, used in Feeding Paths UI, not used in tests yet, ver. 2.11.364 2016-10-12 15:47:45 +02:00
Formulas.cs Buoyancy is 1.00103, not 1001.03 2017-07-19 07:53:52 +02:00
HeatMetersPath.cs HeatMetersPath modifications, DB change. 2016-08-17 10:32:03 +02:00
IOperation.cs Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
MetersPath.cs Qfrom, Qto removed from MetersPath, ver. 2.9.326 2016-07-11 10:20:50 +02:00
OutputPath.cs Drain valve removed from Output path, outPath.Scale.DrainValve used instead of outPath.DrainValve, wait for Event. BalanceDone before 2nd mass measurement in FlyingStartMassCollection, ver. 2.12.519 2017-03-29 09:22:39 +02:00
ProcedureParamsBase.cs XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
State.cs Drain valves are specified as component parameters, tank draining on startup fixed, WaitTankEmptyOp, basic TankDraining management, etc, ver. 2.12.517 2017-03-28 12:50:09 +02:00
StateMachine.cs Graphs changes in progress 2017-09-21 16:44:15 +02:00
TbfComponents.cs Modbus.CometAmbient component implemented (Comet and Easytherms are connected to the same Modbus), ver. 2.17.678 2017-09-28 15:24:10 +02:00
TestBenchSim.cs Symbols: introduced IPERL, ORACLE_DB, HEAT_METERS, TURA_IPERL, TURA_SPECIAL 2017-02-14 13:42:22 +01:00
TestParamsBase.cs XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
Transition.cs Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00