Cause:
- GciBridge Factory used an incorrect namespace substring offset when generating the component class name.
- The generated value was `geComponents.GciBridge` instead of `BridgeComponents.GciBridge`.
- The invalid class name could prevent correct component registration and lookup.
Solution:
1. Corrected class name generation
- Changed the namespace substring offset from 12 to 8.
- GciBridge Factory now returns the correct `BridgeComponents.GciBridge` class name.
2. Restored component identification
- GciBridge can now be registered and resolved using the expected TBF component class name.
3. Increased revision
- Updated revision to 3.9.3145.108.