Cause: - Live diagnostics required logging from multiple applications without blocking TBF. - Shared nlog.config files caused configuration conflicts. - The original viewer lacked configurable colors and practical log controls. - Inconsistent diagnostic deployment caused log transfer failures and locked shared DLLs during builds. Solution: 1. Added universal diagnostic transport - Added AppDiagnostic.Logging with an NLog target and named-pipe communication. - Added background buffering and automatic reconnection. - Registered the diagnostic connector programmatically. 2. Separated diagnostic window lifecycle - Run AppDiagnostic as an independent process. - Activate the existing window on repeated launches. - Keep TBF running when the diagnostic window closes. 3. Corrected diagnostic deployment - Copy the complete diagnostic output into a dedicated AppDiagnostic subdirectory during build. - Overwrite existing deployment files to prevent inconsistent versions. - Validate and launch the executable from that subdirectory with an explicit working directory. 4. Improved the log viewer - Added configurable substring colors with a palette and live preview. - Added text, level and application filters. - Added line wrapping, clipboard actions and log export. - Added Pause/Resume, Refresh, Clear, auto-scroll and Always on top. - Added connection and log counters. - Persist color rules between sessions. 5. Removed legacy dependencies - Replaced LiveLogCache with structured diagnostic storage. - Removed AppDiagnostic dependencies on log4net and SharedComponents. Validation: - Confirmed successful log transfer when launching AppDiagnostic from TBF.
41 lines
1.3 KiB
C#
41 lines
1.3 KiB
C#
using System;
|
|
using System.Collections.Generic;
|
|
using System.Linq;
|
|
using System.Threading;
|
|
using System.Threading.Tasks;
|
|
using System.Windows.Forms;
|
|
|
|
namespace AppDiagnostic
|
|
{
|
|
internal static class Program
|
|
{
|
|
/// <summary>
|
|
/// The main entry point for the application.
|
|
/// </summary>
|
|
[STAThread]
|
|
static void Main()
|
|
{
|
|
bool isFirstInstance;
|
|
|
|
using (var instanceMutex = new Mutex(true, "Sensus.AppDiagnostic.SingleInstance", out isFirstInstance))
|
|
using (var activationEvent = new EventWaitHandle(false, EventResetMode.AutoReset, "Sensus.AppDiagnostic.Activate"))
|
|
{
|
|
if (!isFirstInstance)
|
|
{
|
|
activationEvent.Set();
|
|
return;
|
|
}
|
|
|
|
Application.EnableVisualStyles();
|
|
Application.SetCompatibleTextRenderingDefault(false);
|
|
|
|
using (var diagnosticServer = new DiagnosticPipeServer(DiagnosticLogStore.Instance.Add))
|
|
{
|
|
diagnosticServer.Start();
|
|
Application.Run(new MainForm(() => diagnosticServer.ConnectedClientCount, () => activationEvent.WaitOne(0)));
|
|
}
|
|
}
|
|
}
|
|
}
|
|
}
|