tbf/TBF/UI/Bench/Uncertainties/UncertaintiesDlg.cs

322 lines
14 KiB
C#

///
/// Copyright (c) 2019-2023 Sensus Slovensko a.s.
///
using System;
using System.Collections.Generic;
using System.Windows.Forms;
using NHibernate;
using log4net;
using Config.Entities;
using TBF.Rig;
using TBF.Resources;
using TBF.UI.Shared;
namespace TBF.UI.Bench.Uncertainties
{
public partial class UncertaintiesDlg : Form, IParentOfListViewEx
{
static readonly ILog log = LogManager.GetLogger(typeof(UncertaintiesDlg));
public ISession Session;
public IList<Component> cmpntEntities;
public UncertaintiesDlg()
{
InitializeComponent();
/// Open a database session
try { Session = TBF.DB.ConfigDBSessionFactory.OpenSession(); }
catch (Exception e)
{
MessageBox.Show(Strings.Cannot_connect_to_the_database + Environment.NewLine + e.Message,
Strings.Error, MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
}
/// SharedDlgButtons configuration
sharedButtons.ParentForm = this;
#if KEMPNO_50
sharedButtons.RequiredGroupMembership = new Common.GID[] { Common.GID.MetrologicalAuthority };
#else
sharedButtons.RequiredGroupMembership = new Common.GID[] { Common.GID.Metrologists };
#endif
sharedButtons.OptionalButtons = SharedButtons.Buttons.Add | SharedButtons.Buttons.Remove;
sharedButtons.Unlocked += unlockButton_Click;
sharedButtons.OKClicked += okButton_Click;
sharedButtons.CancelClicked += cancelButton_Click;
sharedButtons.AddClicked += addButton_Click;
sharedButtons.RemoveClicked += removeButton_Click;
}
private void UncertaintiesDlg_Load(object sender, EventArgs e)
{
LoadUISettings();
Text = Strings.Uncertainty;
int fixedCount = 0;
int balancesCount = 0;
int levelMetersCount = 0;
int divertersCount = 0;
int flowMetersCount = 0;
int pressMetersCount = 0;
int tempMetersCount = 0;
int evaporationsCount = 0;
cmpntEntities = (Session == null) ? new List<Component>() : Session.QueryOver<Component>()
.OrderBy(x => x. ItemNr).Asc
.List();
foreach (var cmpnt in cmpntEntities)
{
Rig.Generic.IComponentFactory factory = TbfComponents.CmpntFactoryFromClassName(cmpnt.ClassName);
/// Tab-page density
if (factory is Rig.DataContainers.Density.ComponentFactory)
{
fixedCount++;
TabPage tabPage = new TabPage(" " + Strings.Density + " ");
UncertntDlgDensityTab uiControl = new UncertntDlgDensityTab();
uiControl.MeterEntity = cmpnt;
uiControl.DensityCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.DataContainers.Density.ComponentCfg;
uiControl.Dock = DockStyle.Fill;
tabPage.Tag = uiControl;
tabPage.Controls.Add(uiControl);
uncertaintiesTabControl.TabPages.Add(tabPage);
}
/// Tab-pages for scales
if (factory is Rig.MettlerToledo.Standard.BalanceFactory ||
factory is Rig.MettlerToledo.Standard.BalanceOldFactory ||
factory is Rig.MettlerToledo.Standard.BalanceNewFactory ||
factory is Rig.MettlerToledo.Multi.BalanceFactory)
{
balancesCount++;
TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
UncertntDlgScaleTab uiControl = new UncertntDlgScaleTab();
uiControl.MeterEntity = cmpnt;
uiControl.ScaleCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.GenericDevices.IScaleCfg;
uiControl.Dock = DockStyle.Fill;
tabPage.Tag = uiControl;
tabPage.Controls.Add(uiControl);
uncertaintiesTabControl.TabPages.Add(tabPage);
}
///// Tab-pages for flowmeters
//if (factory is Rig.Elde.FlowMeter.FlowMeterFactory)
//{
// Rig.Elde.FlowMeter.FlowMeterCfg flowMeterCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.Elde.FlowMeter.FlowMeterCfg;
// for (int r = 0; r <= 5; r++)
// {
// if (flowMeterCfg.RangeEnabled(r))
// {
// flowMetersCount++;
// TabPage tabPage = new TabPage(string.Format(((r == 0) ? " {0} " : " {0} r{1} "), cmpnt.Name, r));
// MetrologyDlgFlowMeterTab uiControl = new MetrologyDlgFlowMeterTab(r);
// uiControl.MeterEntity = cmpnt;
// uiControl.CalibInfoCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.GenericDevices.ICalibRangesCfg;
// uiControl.Dock = DockStyle.Fill;
// tabPage.Tag = uiControl;
// tabPage.Controls.Add(uiControl);
// metrologyTabControl.TabPages.Add(tabPage);
// }
// }
//}
/// Tab-pages for pressure meters
if (factory is Rig.Elde.PressureMeter.PressureMeterFactory ||
factory is Rig.Elde.PressureMeterInternal.PressureMeterFactory ||
factory is Rig.Modbus.PressureMeter.Meret.Factory)
{
pressMetersCount++;
TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
UncertntDlgPressMeterTab uiControl = new UncertntDlgPressMeterTab();
uiControl.MeterEntity = cmpnt;
uiControl.Dock = DockStyle.Fill;
tabPage.Tag = uiControl;
tabPage.Controls.Add(uiControl);
uncertaintiesTabControl.TabPages.Add(tabPage);
}
/// Tab-pages for temperature meters (incl. platinum temp. meter with Keithley)
if (factory is Rig.Elde.TempMeter.TempMeterFactory ||
factory is Rig.Elde.TempMeterInternal.TempMeterFactory ||
factory is Rig.Keithley.TempMeter.Factory)
{
tempMetersCount++;
TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
UncertntDlgTempMeterTab uiControl = new UncertntDlgTempMeterTab();
uiControl.MeterEntity = cmpnt;
uiControl.Dock = DockStyle.Fill;
tabPage.Tag = uiControl;
tabPage.Controls.Add(uiControl);
uncertaintiesTabControl.TabPages.Add(tabPage);
}
///// Tab-pages for diverters
//if (factory is Rig.Elde.Diverter.DiverterFactory)
//{
// divertersCount++;
// TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
// MetrologyDlgDiverterTab uiControl = new MetrologyDlgDiverterTab();
// uiControl.MeterEntity = cmpnt;
// uiControl.CalibInfoCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.GenericDevices.ICalibInfoCfg;
// uiControl.Dock = DockStyle.Fill;
// tabPage.Tag = uiControl;
// tabPage.Controls.Add(uiControl);
// metrologyTabControl.TabPages.Add(tabPage);
//}
///// Tab-pages for level meters inside water tanks
//if (factory is Rig.Hart.Nivotrack.Factory)
//{
// levelMetersCount++;
// TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
// MetrologyDlgLevelMeterTab uiControl = new MetrologyDlgLevelMeterTab();
// uiControl.MeterEntity = cmpnt;
// uiControl.CalibInfoCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.GenericDevices.ICalibInfoCfg;
// uiControl.Dock = DockStyle.Fill;
// tabPage.Tag = uiControl;
// tabPage.Controls.Add(uiControl);
// metrologyTabControl.TabPages.Add(tabPage);
//}
///// Tab-pages for water tank evaporation rates
//if (factory is Rig.Various.Evaporation.Factory)
//{
// evaporationsCount++;
// TabPage tabPage = new TabPage(" " + cmpnt.Name + " ");
// MetrologyDlgEvaporationTab uiControl = new MetrologyDlgEvaporationTab();
// uiControl.MeterEntity = cmpnt;
// uiControl.CalibInfoCfg = factory.CmpntCfgFromCmpntEntity(cmpnt) as Rig.GenericDevices.ICalibInfoCfg;
// uiControl.Dock = DockStyle.Fill;
// tabPage.Tag = uiControl;
// tabPage.Controls.Add(uiControl);
// metrologyTabControl.TabPages.Add(tabPage);
//}
}
}
private void unlockButton_Click(object sender, EventArgs e)
{
foreach (TabPage tabPage in uncertaintiesTabControl.TabPages)
{
(tabPage.Tag as IUncetaintiesDlgTab).Unlock();
}
}
private void okButton_Click(object sender, EventArgs e)
{
using (ITransaction transaction = Session.BeginTransaction())
{
try
{
foreach (TabPage tabPage in uncertaintiesTabControl.TabPages)
{
IUncetaintiesDlgTab tab = tabPage.Tag as IUncetaintiesDlgTab;
if (tab != null)
{
tab.OkBtnClicked();
Session.SaveOrUpdate(tab.MeterEntity);
foreach (var entity in tab.ToBeRemoved) Session.Delete(entity);
}
}
transaction.Commit();
Session.Flush();
}
catch (Exception exc)
{
transaction.Rollback();
log.ErrorFormat("Cannot save changes to DB: {0}", exc.Message);
MessageBox.Show(Strings.Cannot_save_changes, Strings.Error, MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
}
}
SaveUISettings();
DialogResult = DialogResult.OK;
Close();
}
private void cancelButton_Click(object sender, EventArgs e)
{
foreach (TabPage tabPage in uncertaintiesTabControl.TabPages)
{
(tabPage.Tag as IUncetaintiesDlgTab).CancelBtnClicked();
}
SaveUISettings();
DialogResult = DialogResult.Cancel;
Close();
}
private void SaveUISettings()
{
/// Obtain UncertaintyDlg dimensions, etc.
bool isMaximized = (WindowState == FormWindowState.Maximized);
int left = (WindowState == FormWindowState.Normal) ? Location.X : RestoreBounds.Left;
int top = (WindowState == FormWindowState.Normal) ? Location.Y : RestoreBounds.Top;
int width = (WindowState == FormWindowState.Normal) ? Size.Width : RestoreBounds.Width;
int height = (WindowState == FormWindowState.Normal) ? Size.Height : RestoreBounds.Height;
LocalSettings ls = Program.LocalSettings;
if (ls != null && (ls.UncertaintyDlgMaximized != isMaximized ||
ls.UncertaintyDlgLeft != left ||
ls.UncertaintyDlgTop != top ||
ls.UncertaintyDlgWidth != width ||
ls.UncertaintyDlgHeight != height))
{
/// At least one UncertaintyDlg dimension differs => Update local settings and save them
ls.UncertaintyDlgMaximized = isMaximized;
ls.UncertaintyDlgLeft = left;
ls.UncertaintyDlgTop = top;
ls.UncertaintyDlgWidth = width;
ls.UncertaintyDlgHeight = height;
ls.Save();
}
}
private void LoadUISettings()
{
TBF.LocalSettings ls = Program.LocalSettings;
WindowState = (ls.UncertaintyDlgMaximized ? FormWindowState.Maximized : FormWindowState.Normal);
Width = (ls.UncertaintyDlgWidth > 0) ? ls.UncertaintyDlgWidth : 900;
Height = (ls.UncertaintyDlgHeight > 0) ? ls.UncertaintyDlgHeight : 500;
Left = (ls.UncertaintyDlgLeft != 0) ? ls.UncertaintyDlgLeft : 200;
Top = (ls.UncertaintyDlgTop != 0) ? ls.UncertaintyDlgTop : 100;
}
private void addButton_Click(object sender, EventArgs e)
{
(uncertaintiesTabControl.SelectedTab.Tag as IUncetaintiesDlgTab).AddOne();
}
private void removeButton_Click(object sender, EventArgs e)
{
(uncertaintiesTabControl.SelectedTab.Tag as IUncetaintiesDlgTab).RemoveSelected();
}
public void UpdateButtonStates(SharedButtons.SelectedItemPos selectedItemPos)
{
if (selectedItemPos == SharedButtons.SelectedItemPos.None)
{
sharedButtons.DisableButtons(SharedButtons.Buttons.Remove);
}
else
{
sharedButtons.EnableButtons(SharedButtons.Buttons.Remove);
}
}
private void metrologyTabControl_SelectedIndexChanged(object sender, EventArgs e)
{
sharedButtons.DisableButtons(SharedButtons.Buttons.Remove);
}
private void UncertaintiesDlg_FormClosing(object sender, FormClosingEventArgs e)
{
if (Users.CurrentUser.Restore(this)) Program.MainWnd.UpdateUser();
if (Session != null && Session.IsOpen) Session.Close();
}
}
}