Cause:
- Closing TBF did not release meter sessions created through the GCI GUI.
- Laatzen keep-session threads could keep the process alive after the main window closed, preventing TBF from starting again.
- A meter disposal failure could interrupt cleanup of the remaining slots and workers.
Solution:
1. Release GCI resources on application exit
- Dispose GCI diagnostic windows and cancel preadjustment.
- Clean meter sessions and slot workers even when the bench was never started.
- Log cleanup failures without skipping other bridge components.
2. Improve cleanup resilience
- Continue disposing remaining meters if one fails.
- Release workers and clear slot references even when meter disposal reports an error.
- Dispose meters outside the batch lock to allow status callbacks during cleanup.
3. Clean resources owned by the standalone GCI view
- Release its API meter sessions when the view is disposed.
4. Increased revision
- Updated AssemblyVersion and AssemblyFileVersion from 3.9.3147.136 to 3.9.3147.137.