Files
marekf f3ed301419 <Fix>: Disable heat meter support for water meter Release builds, increase revision to 3.9.3147.130
Cause:

- Release builds enabled HEAT_METERS and requested heat meter fields from water meter configuration databases.
- Selecting a procedure failed when the Test table did not contain the HeatMetersPath column.

Solution:

1. Align Release configurations for water meters
   - Remove HEAT_METERS from the Release constants in TBF, Config and Results.
   - Exclude heat meter functionality and its conditional database mappings without modifying the database.

2. Validation
   - Config and Results Release builds passed.
   - Full TBF Release build remains blocked by external RFID/NFC dependency and GCI runtime-copy errors.

3. Increased revision
   - Updated AssemblyVersion and AssemblyFileVersion from 3.9.3147.129 to 3.9.3147.130.
2026-10-30 10:17:32 +01:00
..