/// /// Copyright (c) 2017 Sensus Metering Systems /// using System; using System.Collections.Generic; using log4net; using TBF.Boxes; namespace TBF.BenchControl.Elde.RegulValveCoax { public class RegulValve : ComponentBase, GenericDevices.IRegulValve { private static readonly ILog log = LogManager.GetLogger(typeof(RegulValve)); public override string ToString() { return string.Format("RegulValve({0})", Cfg.ToString(1)); } public readonly RegulValveCfg RegulValveCfg; IDictionary dict; public IDictionary Dict { get { return dict; } } public readonly ControlBoardDev ControlBoard; public ValveCategory Category { get { return RegulValveCfg.Category; } } public int Idx1 { get { return RegulValveCfg.Idx1; } } /// 1..7 public int StableTime { get { return RegulValveCfg.StableTime; } } /// 0=200ms, step=50ms, max. 1500ms (max.26) public int FlowStableSec { get { return RegulValveCfg.FlowStableSec; } } /// 0..60 sec /// public bool IsCoax { get { return true; } } /// public float Position { get { return ControlBoard.RValvePosition(Idx1); } } public RegulValve() { } public RegulValve(Generic.IComponentCfg cfg, IList components) : base(cfg) { RegulValveCfg = cfg as RegulValveCfg; ControlBoard = (ControlBoardDev)TbfComponents.FindComponent(cfg.ParentName, components); if (ControlBoard == null) throw new Exception("Cannot find " + Name + " parent"); this.dict = new Dictionary(); log.Debug(this.ToString()); } /// /// Operation to set the water flow within tolerances /// Events: Event.None, Event.FlowReached, Event.FlowTimeOut /// /// Flowmeter component /// Lower limit of the required flow [m3/h] /// Higher limit of the required flow [m3/h] /// PID coefficient (float) /// Measured flow [m3/h] /// Timeout in [s] /// SetFlowOp instance public IOperation SetFlowOp(GenericDevices.IFlowMeter flowMeter, float requiredFlowLo, float requiredFlowHi, float pidCoef, DoubleBox measuredFlow, int timeout) { return new SetFlowOp(ControlBoard, this, flowMeter, requiredFlowLo, requiredFlowHi, pidCoef, measuredFlow, RegulValveCfg.ReTryCommands, timeout); } /// /// Operation to set the water flow within tolerances. Leave the measurement running. /// Events: Event.None, Event.FlowReached, Event.FlowTimeOut /// /// Flowmeter component /// Lower limit of the required flow [m3/h] /// Higher limit of the required flow [m3/h] /// Measured flow [m3/h] /// Timeout in [s] /// SetFlowOp instance public IOperation SetFlowAndMeasureOp(GenericDevices.IFlowMeter flowMeter, float requiredFlowLo, float requiredFlowHi, float pidCoef, DoubleBox measuredFlow, int timeout, float filterConstant) { return new SetFlowOp(ControlBoard, this, flowMeter, requiredFlowLo, requiredFlowHi, pidCoef, measuredFlow, RegulValveCfg.ReTryCommands, timeout, true); } /// /// Operation to set the regulation valve to a required position /// Events: Event.None /// /// Lower limit of the required valve position in [%] /// Higher limit of the required valve position in [%] /// SetPositionOp instance public IOperation SetRegulValvePositionOp(float pctLo, float pctHi, int timeoutMs) { return new SetRegulValvePositionOp(ControlBoard, this, pctLo, pctHi, timeoutMs); } public IOperation ChangeRegulValvePositionOp(float timePulseSec) { return new ChangeRegulValvePositionOp(ControlBoard, this, timePulseSec); } } }