Commit Graph

339 Commits

Author SHA1 Message Date
Milan Hanajik
ec27a5843b TestMehods.GrabImage added, in construction, ver. 2.15.624 2017-07-24 22:14:27 +03:00
Milan Hanajik
8d249a96f4 Fixes in Buoyancy calculation, ver. 2.14.612 2017-07-20 19:54:33 +03:00
Milan Hanajik
9bf66f651a Buoyancy is 1.00103, not 1001.03 2017-07-19 07:53:52 +02:00
Milan Hanajik
77a6aff593 iPerl communication changes (completed as in branch 12 - Greece). 2017-07-18 08:43:16 +02:00
Milan Hanajik
bb962ad3b7 iPerl communication changes (in progress). 2017-07-14 17:13:07 +02:00
Milan Hanajik
00a2289e92 Evaluation of Results.Entities.TestRslt.TestDone, Results.Entities.Batch.Buoyancy() etc. fixed, ver. 2.14.599 2017-07-04 11:19:05 +02:00
Milan Hanajik
e71795bfe5 Masses, Buoyancy, Density corr. added to results, Buoyancy -> TestRslt, Dens.corr. -> Batch, MetrologyDlgDensityTab, etc. 2017-06-29 23:04:17 +02:00
Milan Hanajik
17f6f7c3be XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
Milan Hanajik
b1f1c6f932 TestMethods.Adjustment forms have the control box in the upper-right corner hidden. 2017-06-21 18:29:36 +02:00
Milan Hanajik
ddebe7f8d5 iPerlCommunication/iPerlEnums.cs (enum Q2CorrType) added 2017-06-15 19:08:26 +02:00
Milan Hanajik
6773624cb4 MySQL DB changes for IPERL : FWVersion and FlowMean added, no conflict with FlowMin. 2017-06-15 18:59:05 +02:00
Milan Hanajik
1bf118bdb9 Generic improvements 2017-06-15 18:58:51 +02:00
Milan Hanajik
d2b745dd8e Temperature Tup and Tdown can be checked in Adjustment, Endurance, FlyingStart, FlyingStartMassCollection and FixedStart methods, ver. 2.14.573 2017-06-08 16:55:24 +02:00
Milan Hanajik
db55f5b3fd DB entities, mappings and UI added for 'Control water temp.', 'Temp. lim. lo' and 'Temp. lim. hi'. 2017-06-08 16:06:48 +02:00
Milan Hanajik
f803d27882 More changes, bug fix in ResultsBrowser. 2017-06-08 10:40:52 +02:00
Milan Hanajik
21016a1500 iPerl and iPerlHead separated, iPerl removed (WaterMeter should be used instead). 2017-06-08 09:14:30 +02:00
Milan Hanajik
8a4ad1c2d4 (1) flow calculation for Start/Stop method fixed, (2) iPerl checks the new factor before writing 2017-06-07 16:22:18 +02:00
Milan Hanajik
8b195bd6a9 iPerl : signed/unsigned bug-fix : q2CorrRFlow, q2CorrLFlow 2017-06-01 12:39:59 +02:00
Milan Hanajik
be6240bf28 Automated renaming of paths and transitions, parts 2,3,4. 2017-05-29 15:15:03 +02:00
Milan Hanajik
294cc73e36 tstRslt.FlowMin evaluated, saved to Oracle DB only. 2017-05-25 14:06:05 +02:00
Milan Hanajik
3deb24f89a Automated renaming of paths and transition sequences, part 1. 2017-05-25 12:39:24 +02:00
Milan Hanajik
71613cba5d Q_ref_mean and many other result items added. 2017-05-19 11:25:24 +02:00
Milan Hanajik
6cace280c9 SequenceBase.LogProcessDataHeader() added. 2017-05-10 13:54:38 +02:00
Milan Hanajik
847a4d74d6 UpdateTempPressDensAmb(tstRslt) function added to SequenceBase, used by all sequences. 2017-05-10 10:43:33 +02:00
Milan Hanajik
ed83ae57c5 Progress bars are not displayed as 'completed' when a test was aborted. 2017-05-05 12:46:37 +02:00
Milan Hanajik
17c685148e (1) Flow selection in New Test Wizard extended, (2) MainSeq and BencControlPael modified, etc. 2017-05-03 22:24:25 +02:00
Milan Hanajik
fa57c51786 ProcedureParams initialization/constructors modified. ProcedureParamsBase modified. 2017-05-01 16:03:45 +02:00
Milan Hanajik
59392d8bdc MakeSimulated fixed when there are multiple test repetitions, ver. 2.12.555 2017-05-01 10:28:43 +02:00
Milan Hanajik
a773e42fca iPerl type checked after reading Calibration structure. 2017-04-28 12:59:02 +02:00
Milan Hanajik
eafcf016f3 Setting regulation valves before flow setting disabled, caused porbles all the time, ver. 2.12 549 2017-04-24 11:58:57 +02:00
Milan Hanajik
05982cc2ff Endurance test method sequence modified. 2017-04-24 09:44:11 +02:00
Milan Hanajik
796d9fa554 Camera.Display.DisplayForm modifications 2017-04-09 14:10:49 +02:00
Milan Hanajik
d372a38e7d Camera time read with each sample, calculation : VolumeStart, VolumeEnd, TimestampStart, TimestampEnd used, ver. 2.12.530 2017-04-07 11:29:35 +02:00
Milan Hanajik
fc26b95bdb RoiCfg.SaveImages introduced, Program.ImagesDir introduced - directory cleaned or created on program startup. 2017-04-06 23:49:51 +02:00
Milan Hanajik
44735260ce CLP1611 Measurement done only on successfully detected ROI-s, ver. 2.12.530 2017-04-06 23:47:24 +02:00
Milan Hanajik
6aa3cd96a6 RoiDetection : Changes while testing, ver. 2.12.528 2017-04-06 18:00:33 +02:00
Milan Hanajik
e1eb582804 RoiDetection : Images/cameras for retry of ROI Detection can be selected, ver. 2.12.527 2017-04-06 16:54:27 +02:00
Milan Hanajik
0ad4847972 Network.Camera.Display and ICameraDisplay added, ver. 2.12.526 2017-04-06 15:17:56 +02:00
Milan Hanajik
323f2ede25 RoiDetectionOp modified : File transfer correctly initiated. 2017-04-06 10:27:21 +02:00
Milan Hanajik
464dfc6dd1 FlyingStartMassCollection : 'Next' button can be used to stop the test. 2017-04-05 22:01:21 +02:00
Milan Hanajik
049bbc8655 DEWA Q2 correction modified, Results.Entities.WaterMeter columns added (iPerl only). 2017-03-31 14:17:18 +02:00
Milan Hanajik
5f2da63339 Drain valve removed from Output path, outPath.Scale.DrainValve used instead of outPath.DrainValve, wait for Event. BalanceDone before 2nd mass measurement in FlyingStartMassCollection, ver. 2.12.519 2017-03-29 09:22:39 +02:00
Milan Hanajik
d420128b4b Draining modified, in BERLIN done always before flow setting, ver. 2.12.518 2017-03-28 23:54:52 +02:00
Milan Hanajik
3c4fe34c1d Test_volume_exceeds_the_scale_capacity situation handled correctly, no Error state. 2017-03-27 14:08:53 +02:00
Milan Hanajik
8d4af6f347 Bug in iPerl IRegisterReader usage by FlyingStartMassCollectionSeq fixed, ver. 2.12.501 2017-03-20 17:44:28 +01:00
Milan Hanajik
cd50494141 TestMethods.iPerlCommunication.iPerlCommunicationForm.WriteQ2CorrectionAlt() added. 2017-03-19 22:03:31 +01:00
Milan Hanajik
e245ec80c6 Many changes, Config depends on Users, not vice versa. 2017-03-16 21:53:12 +01:00
Milan Hanajik
0d2099af10 IRegisterReader includes BeginWMState and EndWMState (both double). DataEnty.WMStartState and WMEndState are also double. 2017-03-10 14:31:08 +01:00
Milan Hanajik
87bc0131cf Tests when test volume exceeds the tank capacity cannot be executed, an error message appears. 2017-03-10 13:10:57 +01:00
Milan Hanajik
fa5b427d4d Simulated mode for FixedStartMassCollection method, Bug fix in DataEntry.Standard6.TestStartEndForm, ver. 2.12.485 2017-03-07 19:00:36 +01:00