Milan Hanajik
|
3fb487b67b
|
(1) E9,E10,E15,E16 implemented, (2)Zapiska: Each WM is in one table row, (3) TableRowNr,TableColumnNr,WMRemark added to RsltItems
|
2017-09-25 22:25:09 +02:00 |
|
Milan Hanajik
|
62ceb13385
|
FlowStart and FlowEnd saved into TestRslt at the end of each test.
|
2017-09-13 15:48:31 +02:00 |
|
Milan Hanajik
|
d5904fe9fa
|
ErrorFlags implementation completed. TODO: E9, E10, E11, E12, E15, E16. Ver. 2.16.643
|
2017-08-21 12:36:37 +02:00 |
|
Milan Hanajik
|
20d8fbc389
|
ErrorFlags component added, Results.Entities.TestRslt upgraded to DB v.2.16, ErrorFlags and ErrorFlagsMd added, used in test methods, ver. 2.16.642
|
2017-08-20 09:54:42 +02:00 |
|
Milan Hanajik
|
8ed99092ff
|
Bug fixes in FixedStartMassCollectionSeq, cosmetical changes in DataEntry.StandardCamera, ver. 2.15.634
|
2017-07-28 17:21:30 +03:00 |
|
Milan Hanajik
|
527da6bcc5
|
DataEntry.StandardCamera, Camera.RoiForFixedStart and FixedStartMassCollectionSeq changes, etc, ver. 2.15.632
|
2017-07-28 11:14:20 +03:00 |
|
Milan Hanajik
|
8d623ae8fa
|
FirstStartMassCollectionSeq changes in progress
|
2017-07-27 16:38:46 +03:00 |
|
Milan Hanajik
|
3a38ca6b61
|
bool UsesCameras() added to IDataEntry and DataEntry components, DataEntry.StandardCamera added.
|
2017-07-27 16:37:58 +03:00 |
|
Milan Hanajik
|
8d249a96f4
|
Fixes in Buoyancy calculation, ver. 2.14.612
|
2017-07-20 19:54:33 +03:00 |
|
Milan Hanajik
|
9bf66f651a
|
Buoyancy is 1.00103, not 1001.03
|
2017-07-19 07:53:52 +02:00 |
|
Milan Hanajik
|
00a2289e92
|
Evaluation of Results.Entities.TestRslt.TestDone, Results.Entities.Batch.Buoyancy() etc. fixed, ver. 2.14.599
|
2017-07-04 11:19:05 +02:00 |
|
Milan Hanajik
|
e71795bfe5
|
Masses, Buoyancy, Density corr. added to results, Buoyancy -> TestRslt, Dens.corr. -> Batch, MetrologyDlgDensityTab, etc.
|
2017-06-29 23:04:17 +02:00 |
|
Milan Hanajik
|
d2b745dd8e
|
Temperature Tup and Tdown can be checked in Adjustment, Endurance, FlyingStart, FlyingStartMassCollection and FixedStart methods, ver. 2.14.573
|
2017-06-08 16:55:24 +02:00 |
|
Milan Hanajik
|
db55f5b3fd
|
DB entities, mappings and UI added for 'Control water temp.', 'Temp. lim. lo' and 'Temp. lim. hi'.
|
2017-06-08 16:06:48 +02:00 |
|
Milan Hanajik
|
8a4ad1c2d4
|
(1) flow calculation for Start/Stop method fixed, (2) iPerl checks the new factor before writing
|
2017-06-07 16:22:18 +02:00 |
|
Milan Hanajik
|
294cc73e36
|
tstRslt.FlowMin evaluated, saved to Oracle DB only.
|
2017-05-25 14:06:05 +02:00 |
|
Milan Hanajik
|
71613cba5d
|
Q_ref_mean and many other result items added.
|
2017-05-19 11:25:24 +02:00 |
|
Milan Hanajik
|
6cace280c9
|
SequenceBase.LogProcessDataHeader() added.
|
2017-05-10 13:54:38 +02:00 |
|
Milan Hanajik
|
847a4d74d6
|
UpdateTempPressDensAmb(tstRslt) function added to SequenceBase, used by all sequences.
|
2017-05-10 10:43:33 +02:00 |
|
Milan Hanajik
|
ed83ae57c5
|
Progress bars are not displayed as 'completed' when a test was aborted.
|
2017-05-05 12:46:37 +02:00 |
|
Milan Hanajik
|
eafcf016f3
|
Setting regulation valves before flow setting disabled, caused porbles all the time, ver. 2.12 549
|
2017-04-24 11:58:57 +02:00 |
|
Milan Hanajik
|
05982cc2ff
|
Endurance test method sequence modified.
|
2017-04-24 09:44:11 +02:00 |
|
Milan Hanajik
|
44735260ce
|
CLP1611 Measurement done only on successfully detected ROI-s, ver. 2.12.530
|
2017-04-06 23:47:24 +02:00 |
|
Milan Hanajik
|
5f2da63339
|
Drain valve removed from Output path, outPath.Scale.DrainValve used instead of outPath.DrainValve, wait for Event. BalanceDone before 2nd mass measurement in FlyingStartMassCollection, ver. 2.12.519
|
2017-03-29 09:22:39 +02:00 |
|
Milan Hanajik
|
d420128b4b
|
Draining modified, in BERLIN done always before flow setting, ver. 2.12.518
|
2017-03-28 23:54:52 +02:00 |
|
Milan Hanajik
|
0d2099af10
|
IRegisterReader includes BeginWMState and EndWMState (both double). DataEnty.WMStartState and WMEndState are also double.
|
2017-03-10 14:31:08 +01:00 |
|
Milan Hanajik
|
87bc0131cf
|
Tests when test volume exceeds the tank capacity cannot be executed, an error message appears.
|
2017-03-10 13:10:57 +01:00 |
|
Milan Hanajik
|
fa5b427d4d
|
Simulated mode for FixedStartMassCollection method, Bug fix in DataEntry.Standard6.TestStartEndForm, ver. 2.12.485
|
2017-03-07 19:00:36 +01:00 |
|
Milan Hanajik
|
3fd56531da
|
(1) Genesis component upgraded, (2) FixedStartMassCollectionSeq : Opening start/stop valve in 2nd repetition fixed, ver. 2.12.453
|
2017-02-06 17:44:13 +01:00 |
|
Milan Hanajik
|
38c199f6f9
|
Interfaces between Camera and Roi and sequences finalized, TODO: network communication, ver. 2.12.446
Sequences more robust for debugging, T and Pr-meters checked for null
|
2017-01-25 17:28:57 +01:00 |
|
Milan Hanajik
|
044e53f2b2
|
Changes under construction : ROI registration to Cameras, ver. 2.12.441
|
2017-01-24 12:34:52 +01:00 |
|
Milan Hanajik
|
2150ced11f
|
Propagation of ROI parameters between ROI-s and Cameras implemented, ver. 2.12.438
|
2017-01-22 20:40:12 +01:00 |
|
Milan Hanajik
|
6d45b2c878
|
RoiDetectionSeq modified, ready to be tested.
|
2017-01-16 15:51:34 +01:00 |
|
Milan Hanajik
|
c73cf7002f
|
Camera.Roi.MeasurementOp added, UDP listener added, PulsesPerLtr (and ProcedureParams) added, etc.
|
2017-01-16 13:49:29 +01:00 |
|
Milan Hanajik
|
89901c75f7
|
Revert "Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow."
This reverts commit be52e2df96.
|
2016-12-16 13:07:54 +01:00 |
|
Milan Hanajik
|
be52e2df96
|
Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow.
|
2016-12-12 16:43:04 +01:00 |
|
Milan Hanajik
|
216e08d57c
|
Execute(...) arguments changed everywhere, repetitionNr usage depends on outerLoopMode, outerLoopCounter, ver. 2.12.412
|
2016-12-10 13:03:35 +01:00 |
|
Milan Hanajik
|
98a773700e
|
Bug fix related to PressMtrDelta, ver. 2.12.386
|
2016-11-17 08:48:52 +01:00 |
|
Milan Hanajik
|
52d0c1907f
|
DataEntry.HeatMeters6 and FixedStartMassCollectionSeq bug fixes, ver. 2.12.380
|
2016-10-28 18:45:43 +02:00 |
|
Milan Hanajik
|
bab677c5c2
|
PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373
|
2016-10-18 19:14:01 +02:00 |
|
Milan Hanajik
|
03c027ab33
|
LogProcessDataHeatMeters, ver. 2.11.371
|
2016-10-18 11:49:32 +02:00 |
|
Milan Hanajik
|
0fb3a74879
|
Feeding regulation valves functionality implemented, ver. 2.11.367
|
2016-10-13 16:08:29 +02:00 |
|
Milan Hanajik
|
dddfc4bed5
|
Bug-fixes in FlyingStart and FlyingStartMassCollection heat meters, T ref warm and T ref cold statistics, ver. 2.10.362
|
2016-10-12 01:23:38 +02:00 |
|
Milan Hanajik
|
5f21b5ab26
|
ErrorLimitHi, ErrorLimitLo, EvaluateVolume test parameters added to all heat meters methods.
|
2016-10-10 14:35:59 +02:00 |
|
Milan Hanajik
|
f8331c1c1c
|
Heat meters : Prompt message does not stop the sequence, disappears when conditions met, ver. 2.10.359
|
2016-10-10 14:23:20 +02:00 |
|
Milan Hanajik
|
438028506e
|
Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow)
|
2016-10-07 16:22:36 +02:00 |
|
Milan Hanajik
|
010afcd1e4
|
Temperatures are internally stored and processed in double variables (except of ambient temp.).
|
2016-10-07 15:41:27 +02:00 |
|
Milan Hanajik
|
7df9333fba
|
Statistics return doubles instead of float, casting is done just when writing to entities.
|
2016-10-07 14:46:14 +02:00 |
|
Milan Hanajik
|
4160420844
|
Masses are stored in double variables everywhere.
|
2016-10-07 14:06:54 +02:00 |
|
Milan Hanajik
|
c497c02ef9
|
Heat meters support for measurement with pulses, change in ResultsDB.MeterTestRslt, ver. 2.10.352
|
2016-10-06 10:11:13 +02:00 |
|