Milan Hanajik
c005a5cb26
Solves issue with an opened CycleBeginForm after abort and re-selection in Israel:
...
- CloseCycleBeginForm() -> WaitBeginFormClosed()
- CloseBeginForm() added to SequenceBase(forced dialog close)
- CloseModellFormHandler added to UiBridge.Bridge
2015-03-01 11:13:26 +01:00
Milan Hanajik
82a72670a6
Remaining time displayed for all tests
2015-02-21 20:03:33 +01:00
Milan Hanajik
0c9408ff64
More configuration checks when starting a test
2015-02-02 23:18:28 +01:00
Milan Hanajik
9bd5fba6dc
(1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
...
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik
e1756f692c
Confirmed results to SummaryResults.txt logger
2015-02-02 11:38:42 +01:00
Milan Hanajik
56a9a7cf1b
Test results are written into database after confirming with END
2015-02-02 00:08:47 +01:00
Milan Hanajik
ce6214f631
Zapne pumpu pred vypustanim aj pri ostatnych metodach
2015-02-01 19:30:00 +01:00
Milan Hanajik
85bb34030a
Bugfix in Fixed start method when configuration is NOK, no Dummy RR-s
...
Bugfix in FIxed start method Entry form when config.is NOK, WM-s are missing
2015-01-27 23:00:42 +01:00
Milan Hanajik
5cf5fe5eba
CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change)
2015-01-25 08:11:40 +01:00
Milan Hanajik
d3532a2796
PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
...
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
bb31cdae56
Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results
2015-01-15 06:34:36 +01:00
Milan Hanajik
9c1db2778e
Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page
2015-01-15 03:16:14 +01:00
Milan Hanajik
34dc592e59
Timeout while setting the water flow handled correctly: message displayed, test aborted
2015-01-12 05:56:19 +01:00
Milan Hanajik
de90a4638a
Prepared: PID coefficient of the output path is ready to be used,
...
and not the regul.valve parameter. See // TODO PID: ... in source code.
Database: 'PidCoef' float should be added to 'OutputPath' after col.'FlowMeter'
2015-01-03 21:17:11 +01:00
Milan Hanajik
930db8c379
- many process tab page improvements
...
- program start and state changes logging improved
- IDC100 measurement related changes: reference pulses in RegisterReader
- etc
2014-10-02 20:56:24 +02:00
Milan Hanajik
1c34946a6b
Bugs in sequences fixed: Missing CheckUiOp
2014-09-26 17:48:55 +02:00
Milan Hanajik
2f6f24e281
As sent to ST for the last test on Fuzhou300 system
...
- new component with VZ15 and modified position of VZ13
- fixed start method evaluation OK
- handling of entry forms cleaned-up
2014-09-23 13:16:59 +02:00
Milan Hanajik
b1f7730b96
- FixedStartMassCollection method ready to be tested
...
- FlyingStart method (without mass collection) flow corrections fixed
- DataEntry/WMStates data entry forms added (used by FixedStartMassCollection method)
- minor changes
2014-09-16 21:05:54 +02:00
Milan Hanajik
54ef1e1216
- added BenchControl/Operations/ProcessDataLoggingOp.cs (forgotten in previous commits)
...
- fixed a bug in displayng results and progress controls when two tests had the same name
- some work on data entry forms for FixedStartMassCollection method - not finished yet
2014-09-16 16:09:07 +02:00
Milan Hanajik
a79be1e07a
- bug fixed when component (class) in the DB does not exist in the code
...
- preparing FixedStartMassCollection sequence
2014-09-16 12:04:08 +02:00
Milan Hanajik
a919a3e9d6
- FLyngStart sequence (without balances) tested -> OK, Todo: use
...
corrections
- totalPulses calculated correctly in case of I11+I12 (use of two flowmeters)
2014-09-12 07:18:24 +02:00
Milan Hanajik
fcfdfeca41
- COmponent properties 'Position' --> 'Idx0' or 'Idx1'
...
- process data logging, RegulVal position logging
- changes for I11+I12, NOK yet
2014-09-10 12:05:49 +02:00
Milan Hanajik
d0ebb62ab3
- Component update (temp.)
...
- Process data logging, first trial
2014-09-09 16:18:23 +02:00
Milan Hanajik
354c13853f
All PumpsWithFM are controlled when opening pumps at the test start
2014-09-09 09:14:47 +02:00
Milan Hanajik
6eee83042b
PmpWithFM and Transition sequences functionality implemented
2014-09-08 13:16:31 +02:00
Milan Hanajik
f01a0d84fe
Folder with files for FixedStartMassCollection (copy of FlyingStart..) added to project, builds OK
2014-09-05 09:06:23 +02:00