Milan Hanajik
|
8d249a96f4
|
Fixes in Buoyancy calculation, ver. 2.14.612
|
2017-07-20 19:54:33 +03:00 |
|
Milan Hanajik
|
77a6aff593
|
iPerl communication changes (completed as in branch 12 - Greece).
|
2017-07-18 08:43:16 +02:00 |
|
Milan Hanajik
|
bb962ad3b7
|
iPerl communication changes (in progress).
|
2017-07-14 17:13:07 +02:00 |
|
Milan Hanajik
|
00a2289e92
|
Evaluation of Results.Entities.TestRslt.TestDone, Results.Entities.Batch.Buoyancy() etc. fixed, ver. 2.14.599
|
2017-07-04 11:19:05 +02:00 |
|
Milan Hanajik
|
d2b745dd8e
|
Temperature Tup and Tdown can be checked in Adjustment, Endurance, FlyingStart, FlyingStartMassCollection and FixedStart methods, ver. 2.14.573
|
2017-06-08 16:55:24 +02:00 |
|
Milan Hanajik
|
21016a1500
|
iPerl and iPerlHead separated, iPerl removed (WaterMeter should be used instead).
|
2017-06-08 09:14:30 +02:00 |
|
Milan Hanajik
|
294cc73e36
|
tstRslt.FlowMin evaluated, saved to Oracle DB only.
|
2017-05-25 14:06:05 +02:00 |
|
Milan Hanajik
|
71613cba5d
|
Q_ref_mean and many other result items added.
|
2017-05-19 11:25:24 +02:00 |
|
Milan Hanajik
|
847a4d74d6
|
UpdateTempPressDensAmb(tstRslt) function added to SequenceBase, used by all sequences.
|
2017-05-10 10:43:33 +02:00 |
|
Milan Hanajik
|
ed83ae57c5
|
Progress bars are not displayed as 'completed' when a test was aborted.
|
2017-05-05 12:46:37 +02:00 |
|
Milan Hanajik
|
eafcf016f3
|
Setting regulation valves before flow setting disabled, caused porbles all the time, ver. 2.12 549
|
2017-04-24 11:58:57 +02:00 |
|
Milan Hanajik
|
05982cc2ff
|
Endurance test method sequence modified.
|
2017-04-24 09:44:11 +02:00 |
|
Milan Hanajik
|
d372a38e7d
|
Camera time read with each sample, calculation : VolumeStart, VolumeEnd, TimestampStart, TimestampEnd used, ver. 2.12.530
|
2017-04-07 11:29:35 +02:00 |
|
Milan Hanajik
|
44735260ce
|
CLP1611 Measurement done only on successfully detected ROI-s, ver. 2.12.530
|
2017-04-06 23:47:24 +02:00 |
|
Milan Hanajik
|
049bbc8655
|
DEWA Q2 correction modified, Results.Entities.WaterMeter columns added (iPerl only).
|
2017-03-31 14:17:18 +02:00 |
|
Milan Hanajik
|
d420128b4b
|
Draining modified, in BERLIN done always before flow setting, ver. 2.12.518
|
2017-03-28 23:54:52 +02:00 |
|
Milan Hanajik
|
8d4910fcb0
|
Symbols: introduced IPERL, ORACLE_DB, HEAT_METERS, TURA_IPERL, TURA_SPECIAL
abandoned IPERLST, IPERLSTSPECIAL, HEAT_METERS_SUPPORT
|
2017-02-14 13:42:22 +01:00 |
|
Milan Hanajik
|
38c199f6f9
|
Interfaces between Camera and Roi and sequences finalized, TODO: network communication, ver. 2.12.446
Sequences more robust for debugging, T and Pr-meters checked for null
|
2017-01-25 17:28:57 +01:00 |
|
Milan Hanajik
|
044e53f2b2
|
Changes under construction : ROI registration to Cameras, ver. 2.12.441
|
2017-01-24 12:34:52 +01:00 |
|
Milan Hanajik
|
2150ced11f
|
Propagation of ROI parameters between ROI-s and Cameras implemented, ver. 2.12.438
|
2017-01-22 20:40:12 +01:00 |
|
Milan Hanajik
|
6d45b2c878
|
RoiDetectionSeq modified, ready to be tested.
|
2017-01-16 15:51:34 +01:00 |
|
Milan Hanajik
|
c73cf7002f
|
Camera.Roi.MeasurementOp added, UDP listener added, PulsesPerLtr (and ProcedureParams) added, etc.
|
2017-01-16 13:49:29 +01:00 |
|
Milan Hanajik
|
89901c75f7
|
Revert "Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow."
This reverts commit be52e2df96.
|
2016-12-16 13:07:54 +01:00 |
|
Milan Hanajik
|
be52e2df96
|
Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow.
|
2016-12-12 16:43:04 +01:00 |
|
Milan Hanajik
|
216e08d57c
|
Execute(...) arguments changed everywhere, repetitionNr usage depends on outerLoopMode, outerLoopCounter, ver. 2.12.412
|
2016-12-10 13:03:35 +01:00 |
|
Milan Hanajik
|
98a773700e
|
Bug fix related to PressMtrDelta, ver. 2.12.386
|
2016-11-17 08:48:52 +01:00 |
|
Milan Hanajik
|
bab677c5c2
|
PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373
|
2016-10-18 19:14:01 +02:00 |
|
Milan Hanajik
|
03c027ab33
|
LogProcessDataHeatMeters, ver. 2.11.371
|
2016-10-18 11:49:32 +02:00 |
|
Milan Hanajik
|
0fb3a74879
|
Feeding regulation valves functionality implemented, ver. 2.11.367
|
2016-10-13 16:08:29 +02:00 |
|
Milan Hanajik
|
dddfc4bed5
|
Bug-fixes in FlyingStart and FlyingStartMassCollection heat meters, T ref warm and T ref cold statistics, ver. 2.10.362
|
2016-10-12 01:23:38 +02:00 |
|
Milan Hanajik
|
b3a2c3a0fc
|
FlyingStart, FlyingStartMassCollection and CombinedWithDetection methods support Simulation mode, ver. 2.10.360
|
2016-10-11 12:53:17 +02:00 |
|
Milan Hanajik
|
c84fd8089a
|
FlyingStart and FlyingStartMassCollection methods: 'Begin cycle' dialog closed before 'Heat meters prompt message' is displayed.
|
2016-10-11 09:10:33 +02:00 |
|
Milan Hanajik
|
5f21b5ab26
|
ErrorLimitHi, ErrorLimitLo, EvaluateVolume test parameters added to all heat meters methods.
|
2016-10-10 14:35:59 +02:00 |
|
Milan Hanajik
|
f8331c1c1c
|
Heat meters : Prompt message does not stop the sequence, disappears when conditions met, ver. 2.10.359
|
2016-10-10 14:23:20 +02:00 |
|
Milan Hanajik
|
3c15dbab9e
|
Bug fixes in heat meter testing using pulses, Flying start and Flying start mass collection methods, ver. 2.10.358
|
2016-10-10 11:35:45 +02:00 |
|
Milan Hanajik
|
438028506e
|
Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow)
|
2016-10-07 16:22:36 +02:00 |
|
Milan Hanajik
|
010afcd1e4
|
Temperatures are internally stored and processed in double variables (except of ambient temp.).
|
2016-10-07 15:41:27 +02:00 |
|
Milan Hanajik
|
7df9333fba
|
Statistics return doubles instead of float, casting is done just when writing to entities.
|
2016-10-07 14:46:14 +02:00 |
|
Milan Hanajik
|
c30f905893
|
SLM50 : Bugfix in energy calculation in FlyingStart and FlyingStartMassCollection methods, ver. 2.10.356
|
2016-10-07 10:09:38 +02:00 |
|
Milan Hanajik
|
c497c02ef9
|
Heat meters support for measurement with pulses, change in ResultsDB.MeterTestRslt, ver. 2.10.352
|
2016-10-06 10:11:13 +02:00 |
|
Milan Hanajik
|
c842c50361
|
Heat meters evaluation added to FlyingStartMassCollectionSeq and FlyingStartSeq, ver. 2.10.345
|
2016-08-24 18:30:00 +02:00 |
|
Milan Hanajik
|
0426d2510a
|
Energy and RefEnergy added to ResultsDB, First/Last/Min/Max of all three ambient values added to TestRslt, ver. 2.10.340
|
2016-08-19 15:37:00 +02:00 |
|
Milan Hanajik
|
83ddb7c8bf
|
Waiting loop for temperature stability check in heat meters tests.
|
2016-08-17 18:11:34 +02:00 |
|
Milan Hanajik
|
d4b20876b2
|
All FixedStart, FlyingStart and FlyingStartMassCollection methods reorganised, common sequences used, ver. 2.9.337
|
2016-08-17 15:38:09 +02:00 |
|
Milan Hanajik
|
111e3d8647
|
Minimum and maximum (reference) flow during a test calculated and saved to Results.Entities.TestRslt.
|
2016-08-02 14:48:18 +02:00 |
|
Milan Hanajik
|
ac1bdbe476
|
Bug fix: Updating water meter results in case of a test with parts, copes also with single meters/multiple lines.
|
2016-06-30 14:03:51 +02:00 |
|
Milan Hanajik
|
799fda63e9
|
Bug fix : Updating water meters results in case of test with 'parts'.
|
2016-06-30 12:55:35 +02:00 |
|
Milan Hanajik
|
1337fff2dc
|
Fixed: (1) STOP button does not function in FlyingStart and FlyingStartMassCollection methods, (2) Results.Entities.WaterMeterData.Equals(.)
|
2016-06-15 17:04:25 +02:00 |
|
Milan Hanajik
|
291bb72cf5
|
iPerlCommunicationForm resized depending on the number of iPerl-s, gray color, ver.2.5.273
|
2016-04-23 14:32:15 +02:00 |
|
Milan Hanajik
|
e037720115
|
iPerlST: Logging of a STOP command via UI.
|
2016-04-14 09:16:20 +02:00 |
|