Milan Hanajik
c73cf7002f
Camera.Roi.MeasurementOp added, UDP listener added, PulsesPerLtr (and ProcedureParams) added, etc.
2017-01-16 13:49:29 +01:00
Milan Hanajik
89901c75f7
Revert "Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow."
...
This reverts commit be52e2df96 .
2016-12-16 13:07:54 +01:00
Milan Hanajik
be52e2df96
Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow.
2016-12-12 16:43:04 +01:00
Milan Hanajik
216e08d57c
Execute(...) arguments changed everywhere, repetitionNr usage depends on outerLoopMode, outerLoopCounter, ver. 2.12.412
2016-12-10 13:03:35 +01:00
Milan Hanajik
f3b178473c
Outer loop logic added, TODO: (1) Begin-block and End-block test methods, (2) support in test method sequences
2016-12-10 11:33:31 +01:00
Milan Hanajik
6df36659ab
Dummy.Balance component added
2016-12-09 12:13:59 +01:00
Milan Hanajik
98a773700e
Bug fix related to PressMtrDelta, ver. 2.12.386
2016-11-17 08:48:52 +01:00
Milan Hanajik
bab677c5c2
PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373
2016-10-18 19:14:01 +02:00
Milan Hanajik
d1fb0e0f0a
T warm/cold lo/hi renamed to T hi/lo min/max
2016-10-18 17:27:24 +02:00
Milan Hanajik
03c027ab33
LogProcessDataHeatMeters, ver. 2.11.371
2016-10-18 11:49:32 +02:00
Milan Hanajik
0fb3a74879
Feeding regulation valves functionality implemented, ver. 2.11.367
2016-10-13 16:08:29 +02:00
Milan Hanajik
45e0f50562
Elde.RegulValve supports 'ReTryCommands' parameter (default = false), ver. 2.11.365
2016-10-13 16:08:15 +02:00
Milan Hanajik
dddfc4bed5
Bug-fixes in FlyingStart and FlyingStartMassCollection heat meters, T ref warm and T ref cold statistics, ver. 2.10.362
2016-10-12 01:23:38 +02:00
Milan Hanajik
b3a2c3a0fc
FlyingStart, FlyingStartMassCollection and CombinedWithDetection methods support Simulation mode, ver. 2.10.360
2016-10-11 12:53:17 +02:00
Milan Hanajik
c84fd8089a
FlyingStart and FlyingStartMassCollection methods: 'Begin cycle' dialog closed before 'Heat meters prompt message' is displayed.
2016-10-11 09:10:33 +02:00
Milan Hanajik
5f21b5ab26
ErrorLimitHi, ErrorLimitLo, EvaluateVolume test parameters added to all heat meters methods.
2016-10-10 14:35:59 +02:00
Milan Hanajik
f8331c1c1c
Heat meters : Prompt message does not stop the sequence, disappears when conditions met, ver. 2.10.359
2016-10-10 14:23:20 +02:00
Milan Hanajik
3c15dbab9e
Bug fixes in heat meter testing using pulses, Flying start and Flying start mass collection methods, ver. 2.10.358
2016-10-10 11:35:45 +02:00
Milan Hanajik
438028506e
Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow)
2016-10-07 16:22:36 +02:00
Milan Hanajik
010afcd1e4
Temperatures are internally stored and processed in double variables (except of ambient temp.).
2016-10-07 15:41:27 +02:00
Milan Hanajik
7df9333fba
Statistics return doubles instead of float, casting is done just when writing to entities.
2016-10-07 14:46:14 +02:00
Milan Hanajik
4160420844
Masses are stored in double variables everywhere.
2016-10-07 14:06:54 +02:00
Milan Hanajik
c30f905893
SLM50 : Bugfix in energy calculation in FlyingStart and FlyingStartMassCollection methods, ver. 2.10.356
2016-10-07 10:09:38 +02:00
Milan Hanajik
c497c02ef9
Heat meters support for measurement with pulses, change in ResultsDB.MeterTestRslt, ver. 2.10.352
2016-10-06 10:11:13 +02:00
Milan Hanajik
c842c50361
Heat meters evaluation added to FlyingStartMassCollectionSeq and FlyingStartSeq, ver. 2.10.345
2016-08-24 18:30:00 +02:00
Milan Hanajik
53ead401d0
FixedStartMassCollection : Changes for heat metetrs
2016-08-19 15:37:16 +02:00
Milan Hanajik
0426d2510a
Energy and RefEnergy added to ResultsDB, First/Last/Min/Max of all three ambient values added to TestRslt, ver. 2.10.340
2016-08-19 15:37:00 +02:00
Milan Hanajik
83ddb7c8bf
Waiting loop for temperature stability check in heat meters tests.
2016-08-17 18:11:34 +02:00
Milan Hanajik
011219d491
Heat meters test parameters updated.
2016-08-17 16:32:07 +02:00
Milan Hanajik
d4b20876b2
All FixedStart, FlyingStart and FlyingStartMassCollection methods reorganised, common sequences used, ver. 2.9.337
2016-08-17 15:38:09 +02:00
Milan Hanajik
f7a7987831
Configs.NameOnly.TestMethodCfg[Ctrl] introduced and reused by Adjustment, FixedStartAdvanced, ...
...
... FixedStartCombinedMeters, FixedStartMassCollection, FlyingStart, FlyingStartMassCollection, ReferenceFlowMeterCalibration.
2016-08-15 10:14:14 +02:00
Milan Hanajik
8dae45e10e
IComponentCfg and IComponentFactory interfaces and all derived classes modified.
2016-08-05 14:32:36 +02:00
Milan Hanajik
111e3d8647
Minimum and maximum (reference) flow during a test calculated and saved to Results.Entities.TestRslt.
2016-08-02 14:48:18 +02:00
Milan Hanajik
fa2896d755
Enthalpy calculation (1st ver.), heat meters path modifications (incl. UI)
2016-07-07 16:02:57 +02:00
Milan Hanajik
0ac1fe2b4e
HeatMetersPath, UI, etc., HEAT_METERS_SUPPORT symbol introduced
...
ProcedureDlg modifications: (1) localization by TBF.Resources.Strings, (2) Heat meters support
FlyingStartMassCollection and CombinedMeters methods with similar sequences
2016-07-06 15:59:28 +02:00
Milan Hanajik
ac1bdbe476
Bug fix: Updating water meter results in case of a test with parts, copes also with single meters/multiple lines.
2016-06-30 14:03:51 +02:00
Milan Hanajik
799fda63e9
Bug fix : Updating water meters results in case of test with 'parts'.
2016-06-30 12:55:35 +02:00
Milan Hanajik
1337fff2dc
Fixed: (1) STOP button does not function in FlyingStart and FlyingStartMassCollection methods, (2) Results.Entities.WaterMeterData.Equals(.)
2016-06-15 17:04:25 +02:00
Milan Hanajik
9a725de4a9
Stable mass measurement rewritten, it can use immediate measurement, DB change, ver.2.5.265.
2016-04-14 17:03:33 +02:00
Milan Hanajik
e037720115
iPerlST: Logging of a STOP command via UI.
2016-04-14 09:16:20 +02:00
Milan Hanajik
f901367817
iPerl ST component, symbol IPERLST_SPECIAL, etc. added to the project, ver. 2.4.260.
2016-04-07 15:37:49 +02:00
Milan Hanajik
b006e36d52
Stop Backflow Valve added, used in FlyingStartMassCollection method, ver.2.4.248.
2016-03-18 10:36:33 +08:00
Milan Hanajik
2392bfa2a7
FlyingStartCollectionMethod timing modified, start valve used, ver.2.3.245.
2016-03-17 13:02:25 +08:00
Milan Hanajik
b86ca9fac8
Active FM pump is switched off in 'default action' after test (not when transition sequences are used), ver.2.3.242.
2016-03-15 19:29:47 +08:00
Milan Hanajik
4ab889b43e
Publish, Evaluate test parameters of the Flying start mass collection method excluded.
2016-02-19 10:43:42 +01:00
Milan Hanajik
4b1a684d69
2Hz correction related changes: iPerlCommunication: 'Reset 2Hz correction', 'Write 2Hz correction' + OraDB changes.
2016-02-16 14:44:10 +01:00
Milan Hanajik
462ed568de
Bug fixes: (1) simulation, (2) when BenchInfo==null, (3) ProcessData.RefPulses updated, (4) ProcessTabPages, etc.
2016-02-15 22:48:44 +01:00
Milan Hanajik
edc4d59f90
Process data screen update when test completed, version 2.1.213.
2016-02-13 19:28:33 +01:00
Milan Hanajik
6a159f773e
WMPulses[], WMRefPulses[], WMTimes[] removed from SequenceBase, operations, etc., clean-up.
2016-02-13 17:39:38 +01:00
Milan Hanajik
3946d26cb4
IRegisterReader extended, ReadReferenceForRegisterOp removed, ReadRegisteOp integrated into RegisterReader class, ProcessTabPages updated.
2016-02-13 15:02:10 +01:00