Milan Hanajik
be78bb5ce0
Copyright message added to all cs-files
2015-04-15 20:32:56 +02:00
Milan Hanajik
0323efe57c
PurchaseOrder handling in database and entry forms. DB table TestResult changed.
...
IHasCycleBeginForm and IHasCycleEndForm changed, values now available directly from forms, not only from Watermeters.
2015-03-26 05:53:15 +01:00
Milan Hanajik
23d5e6d19d
Disabled watermeters will not appear in results (screen, ResultsPrinters.Basic and ResultsWriters.Basic).
...
Updating Disabled (default = false) is provided by DataEntry.Standard when entering serial numbers.
2015-03-25 03:57:46 +01:00
Milan Hanajik
9bd5fba6dc
(1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
...
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik
c3f64215f1
ProtocolTitle added to 'Procedure' and 'TestResult'. ResultsWriter-Basic rewritten
2015-01-25 23:43:17 +01:00
Milan Hanajik
5cf5fe5eba
CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change)
2015-01-25 08:11:40 +01:00
Milan Hanajik
ad665e5f0b
Combined meters measurement corrections, Q_rise and Q_fall in results
2015-01-17 08:57:50 +01:00
Milan Hanajik
d3532a2796
PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
...
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
766a3cb2b2
Column Message added to transition steps, DB format changed, not displayed during purging yet
2015-01-11 09:06:54 +01:00
Milan Hanajik
580d4330e3
- PidCoef from OutputPath used in flow control, PidCoef regulValve parameter abandoned
...
- Part field (int) added to Test and TestResult, shown and processed in UI in ProcedureDlg
2015-01-04 23:21:12 +01:00
Milan Hanajik
de90a4638a
Prepared: PID coefficient of the output path is ready to be used,
...
and not the regul.valve parameter. See // TODO PID: ... in source code.
Database: 'PidCoef' float should be added to 'OutputPath' after col.'FlowMeter'
2015-01-03 21:17:11 +01:00
Milan Hanajik
6d6b322fb5
Process screen and Procedure (dlg, DB) changes to suport combined meters, virtual bench.
...
TODO: Visualize changes of pump/valve, diverter, tank
2014-12-12 12:13:43 +01:00
Milan Hanajik
1afd6870c3
Time2MassMsrmt implemented, database tables Test and TestResult changed
2014-12-11 08:49:07 +01:00
Milan Hanajik
26620f1fd1
First unfinished version with VirtualBenchSequences, requires DB upgrade
2014-09-26 15:01:46 +02:00
Milan Hanajik
2f6f24e281
As sent to ST for the last test on Fuzhou300 system
...
- new component with VZ15 and modified position of VZ13
- fixed start method evaluation OK
- handling of entry forms cleaned-up
2014-09-23 13:16:59 +02:00
Milan Hanajik
54ef1e1216
- added BenchControl/Operations/ProcessDataLoggingOp.cs (forgotten in previous commits)
...
- fixed a bug in displayng results and progress controls when two tests had the same name
- some work on data entry forms for FixedStartMassCollection method - not finished yet
2014-09-16 16:09:07 +02:00
Milan Hanajik
d98762aaf8
Transition sequences with PumpsFM[%] are OK in UI and in DB, not yet in the control code
2014-09-07 17:01:30 +02:00
Milan Hanajik
8ff05bcccf
- StartValve added to OutputPath
...
- bug fixed in MeterTestResultMap: 'EndState' was not mapped into the database
2014-09-03 16:55:09 +02:00
Milan Hanajik
8c83965315
ProcedureName added to TestResults entity, Basic writer changes
2014-07-29 15:06:29 +02:00
Milan Hanajik
175a92f633
Initial commit almost identical to SVN-repo rev.340
2014-07-28 09:56:40 +02:00