Commit Graph
16 Commits
Author SHA1 Message Date
Milan Hanajik be78bb5ce0 Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
Milan Hanajik cd1b449585 Metler-Toledo bug fix: When the scale was overloaded, it stopped measuring. 2015-03-25 15:07:39 +01:00
Milan Hanajik a26c90f217 Mass values are printed out using format specified by Balance component parameters 2015-03-25 10:01:37 +01:00
Milan Hanajik b79ae4b1aa PumpTandem component added (to be completed), fixes in component config edit controls 2015-01-11 05:06:18 +01:00
Milan Hanajik 0160dc965d - RegulValve ADC Open/Close values calibration implemented
- 'More' button added to ComponentCfgCtrl-s
- Dataflow from ComponentParametersDlg to components: CfgChangeHandler
- Dataflow from components to ComponentParametersDlg: CmdResponseHandler
- Detection of parameter changes and appropriate MesssageBox display:
  1.warning message when component configuration change requires program restart
  2.confirmation message box when any configuration changes would be lost
2015-01-03 14:45:58 +01:00
Milan Hanajik f2005bbf56 Boilerplate code reduced from factories, GetComponent() and GetControl() added to cfg-s 2015-01-02 19:14:19 +01:00
Milan Hanajik 94de991bf6 Everything works OK after serious changes:
- all components, componentCfg-s and parameter providers use base classes
 - less boilerplate code, simpler access to test/procedure parameters from code
 - CreateTestParams(test), CreateProcedureParams(procedure) methods added
 - TestBenchSim class is made static, it is not inheritted by any device anymore
2015-01-02 12:51:27 +01:00
Milan Hanajik 0ac7ba05d6 Methods CreateDbEntity and CreateFromDbEntity moved from XyzCfg to ComponentCfgBase, factories modified accordingly. 2014-12-29 18:33:27 +01:00
Milan Hanajik ea6c9818cf - Tank emptying remaining time indication
- Bug fixed: When copying a procwdure ItemId was not correctly set, remained 0
- Always create a message log when device initialization is completed successfully
2014-12-10 22:39:53 +01:00
Milan Hanajik 415adba8cf - Tank emptying on start-up implemented, EmptyTimeSec parameter added to Balances
- added events Event.TimerBusy, Event.ValvesBusy, etc.
- fixed bug in SetValvesOp
- preparing a virtual bench drawing on the Process screen - partly done
2014-12-10 12:37:05 +01:00
Milan Hanajik c0d81297f5 Balance empty mass is configurable 2014-09-08 15:39:33 +02:00
Milan Hanajik 74a6800f9e Changes done on Fuzhou300 system:
- ControlComDev.SetFMFreq() modifications (array size)
- StatusP and Route logging
- StatusP bit assignments: bit3 -> bit5
- MettlerToledo logging
2014-09-05 22:14:12 +02:00
Milan Hanajik d177a4f892 - Fixed bugs in (simultaneous) tank emptying 2014-08-11 21:19:47 +02:00
Milan Hanajik fd2db3e229 As sent to Munich 2014-08-01 08:36:17 +02:00
Milan Hanajik 66feec63de Koncim: IBox, etc. 2014-07-31 17:04:09 +02:00
Milan Hanajik 175a92f633 Initial commit almost identical to SVN-repo rev.340 2014-07-28 09:56:40 +02:00