Commit Graph

60 Commits

Author SHA1 Message Date
Milan Hanajik
d2b76cc58d Various bug fixe, ValveMove to flow repeted 1x, version 1.4.42 2015-05-21 16:39:18 +02:00
Milan Hanajik
8afd487e87 CycleBeginning form in DataEntry.Standard24 accepts <enter> and <+> keys. 2015-05-21 15:53:29 +02:00
Milan Hanajik
a1668dc5dd CycleEndForm in DataEntry.Standard can be disabled as well. 2015-05-21 12:51:23 +02:00
Milan Hanajik
4cdf471c68 CycleEndForm in DataEntry.Standard24 can be disabled. 2015-05-21 12:50:41 +02:00
Milan Hanajik
07bd998291 DataEntry.Standard24 Test-Start-End data entry form completed, version 1.4.39 2015-05-21 10:53:28 +02:00
Milan Hanajik
ca4a205fd4 DataEntry.Standard24.TestStartEndForm under construction. 2015-05-20 17:03:49 +02:00
Milan Hanajik
bd56ccb570 DataEntry.Standard24 component added 2015-05-19 20:02:09 +02:00
Milan Hanajik
c01657ec30 Enter can be used to move between fields in DataEntry.Standard TestStartEndForm. 2015-04-29 20:42:58 +02:00
Milan Hanajik
49e58ee789 Error limits for the exclamation mark in EntryForm.Standard TestStartEndForm doubled. 2015-04-29 20:12:43 +02:00
Milan Hanajik
f37cb57427 Bug fixes 2015-04-29 19:59:21 +02:00
Milan Hanajik
e124f3f406 DataEntry.Standard: Exclamation mark displayed when entering the end-state and volume is out of limit. 2015-04-29 19:03:00 +02:00
Milan Hanajik
eb7acef8ae DataEntry.Standard ... TestStartForm (start only) deleted. 2015-04-29 18:17:40 +02:00
Milan Hanajik
94f7298088 DataEntry.Standard TestStartEndForm bugfix. 2015-04-29 17:44:12 +02:00
Milan Hanajik
aac432eb4e DataEntry.Standard form for TestStartEnd. 2015-04-29 17:17:13 +02:00
Milan Hanajik
305bbe9c6c TestStartForm and TestEndForm are two separate forms. DataEntry.Standard.TestEndForm shows start states. 2015-04-29 15:33:49 +02:00
Milan Hanajik
b7bc5659e6 Order added to DataEntry.Combined. TODO: Process checkboxes. s/n history. 2015-04-28 19:19:25 +02:00
Milan Hanajik
d5102fafc7 Dialog size fix. Process tab page flow format fix (4 valid digits). TODO updated. 2015-04-28 19:18:03 +02:00
Milan Hanajik
64a7355e9a Support for units for volume in DataEntry.Combined 2015-04-28 16:39:59 +02:00
Milan Hanajik
cea32b7a59 Volume can be entered either in m3 or in liters in the DataEntry.Standard. 2015-04-28 16:38:37 +02:00
Milan Hanajik
dcfdb00c19 DataEntry.Standard entry form remembers serial numbers. These can be loaded from a drop-down., version = 1.3.19 2015-04-21 22:16:48 +02:00
Milan Hanajik
754bcd3dc6 Comet Ambient added, TODO: Implement the protocol. 2015-04-16 22:06:42 +02:00
Milan Hanajik
be78bb5ce0 Copyright message added to all cs-files 2015-04-15 20:32:56 +02:00
Milan Hanajik
854a2e90c1 Bux fixes: DataEntry.Standard form for fixed start method, modeless form closing. 2015-04-14 11:20:48 +02:00
Milan Hanajik
5822a073df Bug fix: Wrong component class name 2015-04-14 08:23:19 +02:00
Milan Hanajik
274ab79cb7 DataEntry.Standard supports IHasWMStatesForm interface. Fixed start method should work without register readers (test!). 2015-04-14 07:14:45 +02:00
Milan Hanajik
e222c8432d Tester added to Print Order dialog, used in printout. TODO: Chinese 2015-03-27 09:07:44 +01:00
Milan Hanajik
1c69e3e0b1 Cleanup in new forms - protocols deleted. 2015-03-26 17:19:54 +01:00
Milan Hanajik
8b77f4ce68 PrintOrderForm added, invoked from MainWnd menu, uses LocalSettings to store position, load history.
TODO: Complete printing
2015-03-26 17:19:27 +01:00
Milan Hanajik
847862a554 Purchase order history in Local settings 2015-03-26 06:38:03 +01:00
Milan Hanajik
0323efe57c PurchaseOrder handling in database and entry forms. DB table TestResult changed.
IHasCycleBeginForm and IHasCycleEndForm changed, values now available directly from forms, not only from Watermeters.
2015-03-26 05:53:15 +01:00
Milan Hanajik
4342e7a8b2 Bug fixes in Entry Forms 2015-03-25 07:56:55 +01:00
Milan Hanajik
1e63ded8e1 MetersKind.Standard in TBF/Entities/Enums.cs reverted to MetersKind.Single 2015-03-25 05:35:05 +01:00
Milan Hanajik
7dce565e4f MetersKind.Single in TBF/Entities/Enuns.cs renamed to MetersKind.Standard 2015-03-25 02:31:28 +01:00
Milan Hanajik
d1e9537610 DataEntry.Standard (with checkBoxes) and DataEntry.Combined entry forms added.
IWaterMeter.Disabled supported.
2015-03-24 10:09:47 +01:00
Milan Hanajik
9e28856229 Bug fixes in modeless data entry forms. 2015-03-08 09:05:40 +01:00
Milan Hanajik
c005a5cb26 Solves issue with an opened CycleBeginForm after abort and re-selection in Israel:
- CloseCycleBeginForm() -> WaitBeginFormClosed()
- CloseBeginForm() added to SequenceBase(forced dialog close)
- CloseModellFormHandler added to UiBridge.Bridge
2015-03-01 11:13:26 +01:00
Milan Hanajik
8009774c20 Bugfixes: FM pumps % interpretation after adding a pump, Tabs order in entry forms 2015-02-01 11:04:05 +01:00
Milan Hanajik
508f47cb6b Adjustment test method ready for tests 2015-01-28 18:18:46 +01:00
Milan Hanajik
85bb34030a Bugfix in Fixed start method when configuration is NOK, no Dummy RR-s
Bugfix in FIxed start method Entry form when config.is NOK, WM-s are missing
2015-01-27 23:00:42 +01:00
Milan Hanajik
11bdb1b2f1 Bugfix in MainSeq (opening EntryForm instead of closing) 2015-01-15 05:03:46 +01:00
Milan Hanajik
1c3c90e171 CombinedMeters and CombinedWithDetection support SupressTrils bool parameter
Warnings 'Unreachable code' supressed in DataEntries
2015-01-14 05:33:51 +01:00
Milan Hanajik
00b937553c Localization via strings table added to DataEntry.Munich3 (accepts 6 single WM-s) 2015-01-13 09:12:40 +01:00
Milan Hanajik
1f489a481c Entry form DataEntry.Munich modified so that it accepts up to 3 combined WM-s 2015-01-13 08:46:32 +01:00
Milan Hanajik
b79ae4b1aa PumpTandem component added (to be completed), fixes in component config edit controls 2015-01-11 05:06:18 +01:00
Milan Hanajik
0160dc965d - RegulValve ADC Open/Close values calibration implemented
- 'More' button added to ComponentCfgCtrl-s
- Dataflow from ComponentParametersDlg to components: CfgChangeHandler
- Dataflow from components to ComponentParametersDlg: CmdResponseHandler
- Detection of parameter changes and appropriate MesssageBox display:
  1.warning message when component configuration change requires program restart
  2.confirmation message box when any configuration changes would be lost
2015-01-03 14:45:58 +01:00
Milan Hanajik
f2005bbf56 Boilerplate code reduced from factories, GetComponent() and GetControl() added to cfg-s 2015-01-02 19:14:19 +01:00
Milan Hanajik
94de991bf6 Everything works OK after serious changes:
- all components, componentCfg-s and parameter providers use base classes
 - less boilerplate code, simpler access to test/procedure parameters from code
 - CreateTestParams(test), CreateProcedureParams(procedure) methods added
 - TestBenchSim class is made static, it is not inheritted by any device anymore
2015-01-02 12:51:27 +01:00
Milan Hanajik
42c2f88597 Minor and style changes 2014-12-30 00:17:45 +01:00
Milan Hanajik
0ac7ba05d6 Methods CreateDbEntity and CreateFromDbEntity moved from XyzCfg to ComponentCfgBase, factories modified accordingly. 2014-12-29 18:33:27 +01:00
Milan Hanajik
2f6f24e281 As sent to ST for the last test on Fuzhou300 system
- new component with VZ15 and modified position of VZ13
- fixed start method evaluation OK
- handling of entry forms cleaned-up
2014-09-23 13:16:59 +02:00