Milan Hanajik d3532a2796 PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik b79ae4b1aa PumpTandem component added (to be completed), fixes in component config edit controls 2015-01-11 05:06:18 +01:00
Milan Hanajik de90a4638a Prepared: PID coefficient of the output path is ready to be used,
and not the regul.valve parameter. See  // TODO PID: ...  in source code.
 Database: 'PidCoef' float should be added to 'OutputPath' after col.'FlowMeter'
2015-01-03 21:17:11 +01:00
Milan Hanajik 94de991bf6 Everything works OK after serious changes:
- all components, componentCfg-s and parameter providers use base classes
 - less boilerplate code, simpler access to test/procedure parameters from code
 - CreateTestParams(test), CreateProcedureParams(procedure) methods added
 - TestBenchSim class is made static, it is not inheritted by any device anymore
2015-01-02 12:51:27 +01:00
Milan Hanajik 415adba8cf - Tank emptying on start-up implemented, EmptyTimeSec parameter added to Balances
- added events Event.TimerBusy, Event.ValvesBusy, etc.
- fixed bug in SetValvesOp
- preparing a virtual bench drawing on the Process screen - partly done
2014-12-10 12:37:05 +01:00
Milan Hanajik 2f6f24e281 As sent to ST for the last test on Fuzhou300 system
- new component with VZ15 and modified position of VZ13
- fixed start method evaluation OK
- handling of entry forms cleaned-up
2014-09-23 13:16:59 +02:00
Milan Hanajik b1f7730b96 - FixedStartMassCollection method ready to be tested
- FlyingStart method (without mass collection) flow corrections fixed
- DataEntry/WMStates data entry forms added (used by FixedStartMassCollection method)
- minor changes
2014-09-16 21:05:54 +02:00
Milan Hanajik 54ef1e1216 - added BenchControl/Operations/ProcessDataLoggingOp.cs (forgotten in previous commits)
- fixed a bug in displayng results and progress controls when two tests had the same name
- some work on data entry forms for FixedStartMassCollection method - not finished yet
2014-09-16 16:09:07 +02:00
Milan Hanajik 3559ab0ab3 - Elde.FlowMeterCouple component added
- LtrPerPulse and LtrPerPulseCorrected property/function added to IFlowMeter and flowmeters
2014-09-10 13:43:33 +02:00
Milan Hanajik fcfdfeca41 - COmponent properties 'Position' --> 'Idx0' or 'Idx1'
- process data logging, RegulVal position logging
- changes for I11+I12, NOK yet
2014-09-10 12:05:49 +02:00
Milan Hanajik c0d81297f5 Balance empty mass is configurable 2014-09-08 15:39:33 +02:00
Milan Hanajik 6eee83042b PmpWithFM and Transition sequences functionality implemented 2014-09-08 13:16:31 +02:00
Milan Hanajik b8faca784e - ReferenceFlowmeterCalibration method and sequence (ready for tests)
- FlyingStart method and sequence files prepared for implementation (copies of FlyingStartMassCollection)
2014-09-06 17:34:26 +02:00
Milan Hanajik 87f42ba291 Delay added to IValve and Pumps, no delay functionality yet 2014-09-06 08:10:08 +02:00
Milan Hanajik 08468e60d6 - reconfigured to use Munich component and 5 watermeters
- valve categories used in paths, Category property added to IValve
2014-09-02 18:10:16 +02:00
Milan Hanajik 66feec63de Koncim: IBox, etc. 2014-07-31 17:04:09 +02:00
Milan Hanajik 9a9a09f16d TolerRed parameter premenovany a pouzity ako Filter 2014-07-31 00:50:42 +02:00
Milan Hanajik 805e66d537 EndState added to MeterTestResult, UpdateTestResults added to EntryForms and IDataEntry 2014-07-28 23:12:43 +02:00
Milan Hanajik 16228800d4 Implemented an entry form for three single watermeters (for Munich) 2014-07-28 22:13:30 +02:00
Milan Hanajik 175a92f633 Initial commit almost identical to SVN-repo rev.340 2014-07-28 09:56:40 +02:00