Commit Graph

20 Commits

Author SHA1 Message Date
Milan Hanajik
9bd5fba6dc (1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik
e1756f692c Confirmed results to SummaryResults.txt logger 2015-02-02 11:38:42 +01:00
Milan Hanajik
56a9a7cf1b Test results are written into database after confirming with END 2015-02-02 00:08:47 +01:00
Milan Hanajik
ce6214f631 Zapne pumpu pred vypustanim aj pri ostatnych metodach 2015-02-01 19:30:00 +01:00
Milan Hanajik
5cf5fe5eba CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change) 2015-01-25 08:11:40 +01:00
Milan Hanajik
d3532a2796 PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
bb31cdae56 Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results 2015-01-15 06:34:36 +01:00
Milan Hanajik
9c1db2778e Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page 2015-01-15 03:16:14 +01:00
Milan Hanajik
34dc592e59 Timeout while setting the water flow handled correctly: message displayed, test aborted 2015-01-12 05:56:19 +01:00
Milan Hanajik
de90a4638a Prepared: PID coefficient of the output path is ready to be used,
and not the regul.valve parameter. See  // TODO PID: ...  in source code.
 Database: 'PidCoef' float should be added to 'OutputPath' after col.'FlowMeter'
2015-01-03 21:17:11 +01:00
Milan Hanajik
1afd6870c3 Time2MassMsrmt implemented, database tables Test and TestResult changed 2014-12-11 08:49:07 +01:00
Milan Hanajik
930db8c379 - many process tab page improvements
- program start and state changes logging improved
- IDC100 measurement related changes: reference pulses in RegisterReader
- etc
2014-10-02 20:56:24 +02:00
Milan Hanajik
1c34946a6b Bugs in sequences fixed: Missing CheckUiOp 2014-09-26 17:48:55 +02:00
Milan Hanajik
a79be1e07a - bug fixed when component (class) in the DB does not exist in the code
- preparing FixedStartMassCollection sequence
2014-09-16 12:04:08 +02:00
Milan Hanajik
a919a3e9d6 - FLyngStart sequence (without balances) tested -> OK, Todo: use
corrections
- totalPulses calculated correctly in case of I11+I12 (use of two flowmeters)
2014-09-12 07:18:24 +02:00
Milan Hanajik
fcfdfeca41 - COmponent properties 'Position' --> 'Idx0' or 'Idx1'
- process data logging, RegulVal position logging
- changes for I11+I12, NOK yet
2014-09-10 12:05:49 +02:00
Milan Hanajik
d0ebb62ab3 - Component update (temp.)
- Process data logging, first trial
2014-09-09 16:18:23 +02:00
Milan Hanajik
354c13853f All PumpsWithFM are controlled when opening pumps at the test start 2014-09-09 09:14:47 +02:00
Milan Hanajik
6eee83042b PmpWithFM and Transition sequences functionality implemented 2014-09-08 13:16:31 +02:00
Milan Hanajik
b8faca784e - ReferenceFlowmeterCalibration method and sequence (ready for tests)
- FlyingStart method and sequence files prepared for implementation (copies of FlyingStartMassCollection)
2014-09-06 17:34:26 +02:00