Milan Hanajik
94de991bf6 Everything works OK after serious changes:
- all components, componentCfg-s and parameter providers use base classes
 - less boilerplate code, simpler access to test/procedure parameters from code
 - CreateTestParams(test), CreateProcedureParams(procedure) methods added
 - TestBenchSim class is made static, it is not inheritted by any device anymore
2015-01-02 12:51:27 +01:00
Milan Hanajik
0ac7ba05d6 Methods CreateDbEntity and CreateFromDbEntity moved from XyzCfg to ComponentCfgBase, factories modified accordingly. 2014-12-29 18:33:27 +01:00
Milan Hanajik
930db8c379 - many process tab page improvements
- program start and state changes logging improved
- IDC100 measurement related changes: reference pulses in RegisterReader
- etc
2014-10-02 20:56:24 +02:00
Milan Hanajik
1c34946a6b Bugs in sequences fixed: Missing CheckUiOp 2014-09-26 17:48:55 +02:00
Milan Hanajik
2f6f24e281 As sent to ST for the last test on Fuzhou300 system
- new component with VZ15 and modified position of VZ13
- fixed start method evaluation OK
- handling of entry forms cleaned-up
2014-09-23 13:16:59 +02:00
Milan Hanajik
b1f7730b96 - FixedStartMassCollection method ready to be tested
- FlyingStart method (without mass collection) flow corrections fixed
- DataEntry/WMStates data entry forms added (used by FixedStartMassCollection method)
- minor changes
2014-09-16 21:05:54 +02:00
Milan Hanajik
54ef1e1216 - added BenchControl/Operations/ProcessDataLoggingOp.cs (forgotten in previous commits)
- fixed a bug in displayng results and progress controls when two tests had the same name
- some work on data entry forms for FixedStartMassCollection method - not finished yet
2014-09-16 16:09:07 +02:00
Milan Hanajik
a79be1e07a - bug fixed when component (class) in the DB does not exist in the code
- preparing FixedStartMassCollection sequence
2014-09-16 12:04:08 +02:00
Milan Hanajik
a919a3e9d6 - FLyngStart sequence (without balances) tested -> OK, Todo: use
corrections
- totalPulses calculated correctly in case of I11+I12 (use of two flowmeters)
2014-09-12 07:18:24 +02:00
Milan Hanajik
fcfdfeca41 - COmponent properties 'Position' --> 'Idx0' or 'Idx1'
- process data logging, RegulVal position logging
- changes for I11+I12, NOK yet
2014-09-10 12:05:49 +02:00
Milan Hanajik
d0ebb62ab3 - Component update (temp.)
- Process data logging, first trial
2014-09-09 16:18:23 +02:00
Milan Hanajik
354c13853f All PumpsWithFM are controlled when opening pumps at the test start 2014-09-09 09:14:47 +02:00
Milan Hanajik
6eee83042b PmpWithFM and Transition sequences functionality implemented 2014-09-08 13:16:31 +02:00
Milan Hanajik
f01a0d84fe Folder with files for FixedStartMassCollection (copy of FlyingStart..) added to project, builds OK 2014-09-05 09:06:23 +02:00