Commit Graph

95 Commits

Author SHA1 Message Date
Milan Hanajik
94de991bf6 Everything works OK after serious changes:
- all components, componentCfg-s and parameter providers use base classes
 - less boilerplate code, simpler access to test/procedure parameters from code
 - CreateTestParams(test), CreateProcedureParams(procedure) methods added
 - TestBenchSim class is made static, it is not inheritted by any device anymore
2015-01-02 12:51:27 +01:00
Milan Hanajik
752719bd62 Getting rid of and suppressing WARNING messages 2014-12-31 13:44:47 +01:00
Milan Hanajik
13f151b39a Support for PT200 Israel added, fixed component for Fuzhou300 (I4 problem) 2014-12-30 13:25:01 +01:00
Milan Hanajik
42c2f88597 Minor and style changes 2014-12-30 00:17:45 +01:00
Milan Hanajik
0ac7ba05d6 Methods CreateDbEntity and CreateFromDbEntity moved from XyzCfg to ComponentCfgBase, factories modified accordingly. 2014-12-29 18:33:27 +01:00
Milan Hanajik
8ef0cea1ff One more change in transition sequences with more RV-s changed in one step 2014-12-28 09:08:39 +01:00
Milan Hanajik
7472040cbc Last minute changes: German, ext-comm flag 2014-12-12 15:05:27 +01:00
Milan Hanajik
4794000f75 Fixed a bug in transition sequences with more RV-s changed in one step 2014-12-12 13:57:24 +01:00
Milan Hanajik
6d6b322fb5 Process screen and Procedure (dlg, DB) changes to suport combined meters, virtual bench.
TODO: Visualize changes of pump/valve, diverter, tank
2014-12-12 12:13:43 +01:00
Milan Hanajik
0808351b7a Change so that the component is used as on DN100 in horna skusobna 2014-12-11 12:56:50 +01:00
Milan Hanajik
89ae1bb52f Fixed bug: Wrong test selection when parts of the name match each other (e.g.Q1 and Q10) 2014-12-11 09:04:06 +01:00
Milan Hanajik
1afd6870c3 Time2MassMsrmt implemented, database tables Test and TestResult changed 2014-12-11 08:49:07 +01:00
Milan Hanajik
ea6c9818cf - Tank emptying remaining time indication
- Bug fixed: When copying a procwdure ItemId was not correctly set, remained 0
- Always create a message log when device initialization is completed successfully
2014-12-10 22:39:53 +01:00
Milan Hanajik
42c255e40e More changes in VirtualBench drawing on the Process screen 2014-12-10 17:14:03 +01:00
Milan Hanajik
415adba8cf - Tank emptying on start-up implemented, EmptyTimeSec parameter added to Balances
- added events Event.TimerBusy, Event.ValvesBusy, etc.
- fixed bug in SetValvesOp
- preparing a virtual bench drawing on the Process screen - partly done
2014-12-10 12:37:05 +01:00
Milan Hanajik
6aada39d97 Reconfigured for 'Munich' installation 2014-12-07 22:32:41 +01:00
Milan Hanajik
b1743662f4 Change that makes it possible to use IDC100 v.8.0.6d 2014-10-15 20:47:04 +02:00
Milan Hanajik
54595c9ebd ROI detection handled separately from (fatal) camera errors 2014-10-13 17:54:15 +02:00
Milan Hanajik
930db8c379 - many process tab page improvements
- program start and state changes logging improved
- IDC100 measurement related changes: reference pulses in RegisterReader
- etc
2014-10-02 20:56:24 +02:00
Milan Hanajik
b6bbad66e7 IDC Camera related fixes - to be tested 2014-10-02 18:05:54 +02:00
Milan Hanajik
deb6b90332 VirtualBenchSequences UI completed, delete step is not OK yet 2014-09-28 22:23:41 +02:00
Milan Hanajik
1c34946a6b Bugs in sequences fixed: Missing CheckUiOp 2014-09-26 17:48:55 +02:00
Milan Hanajik
26620f1fd1 First unfinished version with VirtualBenchSequences, requires DB upgrade 2014-09-26 15:01:46 +02:00
Milan Hanajik
9868c41640 Zmeny urobene v ST pri testovani kamery 2014-09-24 19:58:05 +02:00
Milan Hanajik
09affdb1dd Bug fixed in ControlComWrap logging: fmFreq.Length taken into account 2014-09-24 17:03:46 +02:00
Milan Hanajik
fcea95d403 Process screen hides additional watermeters (if their number is < 6). 2014-09-24 15:38:54 +02:00
Milan Hanajik
5bfc348c72 Project reconfigured for DN100 (horna skusobna), no other changes 2014-09-24 12:41:18 +02:00
Milan Hanajik
2f6f24e281 As sent to ST for the last test on Fuzhou300 system
- new component with VZ15 and modified position of VZ13
- fixed start method evaluation OK
- handling of entry forms cleaned-up
2014-09-23 13:16:59 +02:00
Milan Hanajik
c3bfe5223b - The update of the 6th watermeter data in ProcessTabPageCtrl fixed
- Valve/Pump delay evaluation modified: Delays of valves/pums that have not changed
  are not taken into account (faster when there is no valve/pump switching)
2014-09-17 19:17:05 +02:00
Milan Hanajik
15ab22362e - Number of watermeters increased to 6 for FUZHOU300
- DB table 'MetersPath' update required
2014-09-16 21:19:02 +02:00
Milan Hanajik
b1f7730b96 - FixedStartMassCollection method ready to be tested
- FlyingStart method (without mass collection) flow corrections fixed
- DataEntry/WMStates data entry forms added (used by FixedStartMassCollection method)
- minor changes
2014-09-16 21:05:54 +02:00
Milan Hanajik
54ef1e1216 - added BenchControl/Operations/ProcessDataLoggingOp.cs (forgotten in previous commits)
- fixed a bug in displayng results and progress controls when two tests had the same name
- some work on data entry forms for FixedStartMassCollection method - not finished yet
2014-09-16 16:09:07 +02:00
Milan Hanajik
a79be1e07a - bug fixed when component (class) in the DB does not exist in the code
- preparing FixedStartMassCollection sequence
2014-09-16 12:04:08 +02:00
Milan Hanajik
c187dc9abf - FlyingStart with corrections
- FlowMeterCouple -> FlowMeterTwins
2014-09-15 22:00:37 +02:00
Milan Hanajik
a919a3e9d6 - FLyngStart sequence (without balances) tested -> OK, Todo: use
corrections
- totalPulses calculated correctly in case of I11+I12 (use of two flowmeters)
2014-09-12 07:18:24 +02:00
Milan Hanajik
3559ab0ab3 - Elde.FlowMeterCouple component added
- LtrPerPulse and LtrPerPulseCorrected property/function added to IFlowMeter and flowmeters
2014-09-10 13:43:33 +02:00
Milan Hanajik
fcfdfeca41 - COmponent properties 'Position' --> 'Idx0' or 'Idx1'
- process data logging, RegulVal position logging
- changes for I11+I12, NOK yet
2014-09-10 12:05:49 +02:00
Milan Hanajik
c3050863a6 - Component update (temp., etc.)
- Process data logging update (SequenceBase.cs)
2014-09-09 18:29:01 +02:00
Milan Hanajik
d0ebb62ab3 - Component update (temp.)
- Process data logging, first trial
2014-09-09 16:18:23 +02:00
Milan Hanajik
4db4c6e905 New component with Temperatures corrected, other minor/cosmetical changes 2014-09-09 13:06:10 +02:00
Milan Hanajik
354c13853f All PumpsWithFM are controlled when opening pumps at the test start 2014-09-09 09:14:47 +02:00
Milan Hanajik
d14cb175a6 FlowStableSec parameter added to RegulValve 2014-09-08 20:24:46 +02:00
Milan Hanajik
cc2a24cee5 - Fixed a bug in tank emptying
- Component
2014-09-08 17:13:51 +02:00
Milan Hanajik
c0d81297f5 Balance empty mass is configurable 2014-09-08 15:39:33 +02:00
Milan Hanajik
9223483115 Early entered text checks in Transitions dialog 2014-09-08 14:48:48 +02:00
Milan Hanajik
6eee83042b PmpWithFM and Transition sequences functionality implemented 2014-09-08 13:16:31 +02:00
Milan Hanajik
d98762aaf8 Transition sequences with PumpsFM[%] are OK in UI and in DB, not yet in the control code 2014-09-07 17:01:30 +02:00
Milan Hanajik
46861530a8 MainWnd size, location and maximized state saved. 2014-09-07 12:36:40 +02:00
Milan Hanajik
99377ce3b9 Size and location of some dialogs saved: Components, Paths, Transitions, Metrology, Procedures, Procedure 2014-09-07 09:34:28 +02:00
Milan Hanajik
f9d2c43d57 - Tank empty threshold changed (increased)
- Fixed a bug in SequenceBase.LtrPerRefPulse[] initialization
2014-09-06 18:30:13 +02:00