marekf 1c6f9af2bb <Feat>: Add standalone Genesis preadjustment activities, fix configuration control and increase revision to 3.9.3146.101
Cause:

- GenesisCommunication did not expose GCI preadjustment phases as selectable test activities.
- Meter size and temperature inputs required by preadjustment could not be configured.
- The configuration control incorrectly expected the iPerlCommunication configuration type.
- Preadjustment results were not propagated to TBF test and meter results.

Solution:

1. Added standalone preadjustment activities
   - Added Initialization, Detect, Preparation, Amplitude Test, Temperature Calibration, Push Temperature, Offset Test and Completion.
   - Each phase can be selected and executed independently.

2. Added preadjustment parameters
   - Added configurable meter size and temperature.
   - Added validation and supported meter-size selection.

3. Added batch preadjustment execution
   - Resolves enabled Genesis register readers and their slots.
   - Verifies that all readers use the same GCI Bridge instance.
   - Dispatches the selected activity through the corresponding GCI Bridge API.

4. Added result processing
   - Stores execution time and completion status.
   - Updates test and meter results according to the GCI response.

5. Fixed the configuration control
   - Corrected TestMethodCfgCtrl to accept the GenesisCommunication TestMethodCfg type.

6. Increased revision
   - Updated revision to 3.9.3146.101.
2026-09-10 14:08:00 +02:00
marekf 0cfde7f06b <Update>: Version to 3.9.3146.0 in AssemblyInfo files 2026-09-09 17:31:27 +02:00
marekf 8677e49680 <Fix>: Correct GciBridge component class name generation, increase revision to 3.9.3145.108
Cause:

- GciBridge Factory used an incorrect namespace substring offset when generating the component class name.
- The generated value was `geComponents.GciBridge` instead of `BridgeComponents.GciBridge`.
- The invalid class name could prevent correct component registration and lookup.

Solution:

1. Corrected class name generation
   - Changed the namespace substring offset from 12 to 8.
   - GciBridge Factory now returns the correct `BridgeComponents.GciBridge` class name.

2. Restored component identification
   - GciBridge can now be registered and resolved using the expected TBF component class name.

3. Increased revision
   - Updated revision to 3.9.3145.108.
2026-09-08 22:00:31 +02:00
marekf 29faef86e3 <Fix>: Prevent GciBridge startup failure when storage components are unavailable, increase revision to 3.9.3145.107
Cause:

- GciBridge threw an exception when the configured UniDataStorageReader or UniDataStorageWriter was not available during component initialization.
- The exception prevented TBF from starting and made it impossible to correct the component configuration through the UI.

Solution:

1. Improved missing component handling
   - Replaced fatal exceptions for missing storage components with warning logs.
   - Allowed GciBridge and TBF to continue initialization.

2. Preserved existing behavior
   - Available UniDataStorageReader and UniDataStorageWriter components are still linked as before.
   - Existing GciBridge configurations remain compatible.

3. Increased revision
   - Updated revision to 3.9.3145.107.
2026-09-08 21:59:29 +02:00
marekf 6ef42fcc21 <Feat>: Add optional TestID filtering for repeating XML results, increase revision to 3.9.3145.106
Cause:

- Repeating XML output always included every published meter test.
- The existing TestID/Prüfpunkt configuration was not used to filter generated XML test records.
- A configured TestID could be evaluated in an incorrect repeating test context.

Solution:

1. Added optional test filtering
   - Non-empty TestID values define the tests included in repeating XML output.
   - Multiple configured TestID values act as a whitelist.

2. Preserved existing behavior
   - When no TestID is configured, all published tests are exported as before.
   - Existing configurations remain compatible without migration.

3. Prevented cross-test evaluation
   - Test-dependent items are evaluated only for their matching TestID.
   - Values from one test are no longer reused in another test record.

4. Improved source formatting
   - Reformatted ResultsWriter.cs for easier reading and searching.

5. Increased revision
   - Updated revision to 3.9.3145.106.
2026-09-08 14:11:09 +02:00
marekf d2d41df155 <Fix>: Restore parent UniDataStorageWriter in Previous results editor, increase revision to 3.9.3145.105
Cause:

- Previous results opens the ResultsWriter configuration through GetControl(null).
- The component entity list is therefore unavailable.
- The DropDownList could not display the saved ParentName because it was not present in its Items collection.

Solution:

1. Restored the saved parent writer
   - Adds the configured ParentName to the list when it is not already available.
   - Selects the restored UniDataStorageWriter in parentComboBox.

2. Preserved standard configuration behavior
   - All available UDSW components are still loaded when component entities are provided.
   - Previous results can now display and use the previously configured parent writer.

3. Improved source formatting
   - Removed inappropriate line wrapping from ResultsWriterCfgCtrl.cs.

4. Increased revision
   - Updated revision to 3.9.3145.105.
2026-09-08 13:20:55 +02:00
marekf 6d2477be4a <Feat>: Enable TestID column in ResultsWriter configuration, increase revision to 3.9.3145.104
Cause:

- ResultsWriter explicitly suppressed the existing TestID column.
- Users could not configure the test identifier for test-dependent result variables.
- In the German localization, the corresponding Prüfpunkt column was therefore hidden.

Solution:

1. Enabled TestID configuration
   - Set SupressTestIDColumn to false.
   - The TestID/Prüfpunkt column is now displayed after Merge.

2. Preserved existing configuration handling
   - TestID values continue to use the existing WMeterRsltItemSpec serialization.
   - No configuration format change was required.

3. Increased revision
   - Updated revision to 3.9.3145.104.
2026-09-08 12:54:53 +02:00
marekf 57152ae749 <Feat>: Add XML-based payload archive filename configuration, increase revision to 3.9.3145.103
Cause:

- Payload archive filenames required values from the generated XML payload.
- Date/time values needed filename-safe formatting.
- XML result values such as Passed and Failed needed configurable conversion to P and F.

Solution:

1. Added XML filename tokens
   - Supports any unique non-repeating XML value using {Xml:/path}.
   - Resolves filename values directly from the generated payload.

2. Added user-friendly token configuration
   - Clicking inside a token opens the XML value chooser.
   - Added Time format and Mask transformations.

3. Improved filename generation
   - Validates XML paths and rejects ambiguous repeating values.
   - Sanitizes resolved values for safe filesystem usage.
   - Passes the per-meter payload context from ResultsWriter.

4. Integrated the new dialog
   - Added PayloadFileNameXmlTokenDlg and its Designer file.
   - Updated the TBF project configuration.

5. Increased revision
   - Updated revision to 3.9.3145.103.
2026-09-08 12:52:40 +02:00
marekf 136be96e1b <Feat>: Add customer XML structure mapping support in ResultsWriter, increase revision to 3.9.3145.102
Cause:

- The customer XML format requires batch, DUT, group and test-level metadata.
- ResultsWriter did not provide variables for test position, repetition index, batch duration, DUT test duration or aggregated test statuses.
- Missing WaterMeterData could cause a NullReferenceException while evaluating WM Type.

Solution:

1. Added XML mapping variables
   - Added TestPositionInBatch and TestRepetitionNr.
   - Added BatchTime and TestsTotalTime.
   - Added PassedFromAllTests and PassedFromRepeatedTests.

2. Added hierarchical result evaluation
   - Evaluates the overall PANEL/DUT status from all tests.
   - Evaluates GROUP status from repeated instances of the selected test.

3. Improved meter data handling
   - Made WM Type evaluation null-safe when WaterMeterData is unavailable.

4. Increased revision
   - Updated revision to 3.9.3145.102.
2026-09-04 08:20:50 +02:00
marekf d3c8813012 <Fix>: Correct test-dependent result evaluation in ResultsWriter, increase revision to 3.9.3145.101
Cause:

- ResultsWriter evaluated selected test-dependent items without the actual TestID.
- This caused values such as Test passed(), timestamps, flow, pressure, temperature, conductivity and error data to be empty or incorrect.

Solution:

1. Fixed test-aware result evaluation
   - Uses published regular meter test results.
   - Passes mtr.Name() as TestID to item.Print(wm, testId).

2. Restored correct test result mapping
   - Test-dependent values are now resolved from the correct TestRslt / MeterTestRslt.

3. Increased revision
   - Updated revision to 3.9.3145.101.
2026-09-03 10:00:40 +02:00
marekf 054075a341 <Feat>: Add XML result generation with file and MSSQL output support, increase revision to 3.9.3145.100
Cause:

- ResultsWriter required a generic way to generate customer-specific XML result data from TBF measurement results.
- The customer reference XML contains example runtime values and repeated result structures, so it cannot be used directly as the generated output.
- TBF result variables must be explicitly mapped to destinations in the customer XML structure.
- The generated XML result data must support two output targets:
  - direct creation of an XML file,
  - delivery of the XML payload to a Microsoft SQL stored procedure.
- Preview generation must allow the XML structure and configured mappings to be verified without executing the production database write.
- Increase revision to 3.9.3145.100.

Solution:

1. Added XML reference analysis
   - Creates a clean base XML structure.
   - Extracts the repeating result prototype.
   - Prevents sample runtime values from the customer reference XML from leaking into generated results.
2. Added configurable TBF-to-XML result mapping
   - Allows explicit mapping of TBF result variables to customer XML destinations.
   - Supports one-time and repeating XML destinations.
   - Keeps the mapping independent of the semantic meaning of customer XML attribute names.
3. Added XML destination viewer and configurator
   - Shows the current mapping.
   - Highlights repeating destinations.
   - Identifies already used one-time destinations.
4. Added runtime XML result generation
   - Uses the configured TBF-to-XML mappings.
   - Uses measurement procedure result data.
   - Builds the output from the clean base XML and repeating XML prototype.
   - Generates repeated result records according to the executed measurement procedure.
5. Added simulation-based Preview request
   - Generates a complete XML payload using simulation values.
   - Allows XML structure and mapping verification before production execution.
   - Does not execute the production stored procedure.
6. Added direct XML file output support to UniDataStorageWriter
   - Supports File / .xml as a physical output target.
   - Creates the generated XML result file in the configured output directory.
7. Added Microsoft SQL stored-procedure XML output
   - Supports Microsoft SQL / StoredProcedure as a physical output target.
   - Passes the generated XML payload through the configured stored procedure parameter.
8. Added optional XML payload archiving
   - Allows generated XML payloads to be stored in the configured Payload archive.
   - Can be used together with the Microsoft SQL stored-procedure output.
9. Kept ResultsWriter independent of the physical output target
   - ResultsWriter generates the result payload.
   - UniDataStorageWriter decides how and where the payload is physically written.
   - The same ResultsWriter XML generation mechanism is therefore used for both XML file and MSSQL outputs.
10. Increased revision
   - Updated revision to 3.9.3145.100.
2026-09-02 12:05:10 +02:00
marekf a0d53f9ec9 <Fix>: RefPulses carry-over by restoring testInProgress behavior in StandingStart, increase revision to 3.9.3145
Cause:
1. Background: Restore/ensure testInProgress behavior before the DataEntry sequence and explicitly prevent to reset the pulse.
2. Increase revision to 3.9.3145

Solution:
1. Deleted .AddOperation(testInProgress) calling
2. Increased revision to 3.9.3145
2026-08-25 13:49:49 +02:00
marekf 1e45f48c75 <Update>: Version to 3.9.3144.0 in AssemblyInfo files 2026-08-25 08:23:27 +02:00
michal 26db172153 Camera WM Purchase Order - crop disabled 2026-08-24 12:21:49 +02:00
michal 2e75f65b4a Update version to 3.9.3142.0 in AssemblyInfo files 2026-08-20 00:27:39 +02:00
michal b904d0ca41 Fix Flip Mode - ver. 3.9.3141.0
Add robust handling for form closure in UNI Data Entry: prevent operations on disposed/closing forms, enhance logging, and update logic in serial number and volume updates. Increment version to 3.9.3141.0.
2026-08-19 19:13:41 +02:00
michal f34046df2a Update version to 3.9.3140.0 in AssemblyInfo files - FIX DataEntry.UNI 2026-08-19 14:49:24 +02:00
michal a4ef208233 Fix ver. 3.9.3139 iPerlCommunicationForm.cs problems + exceptions if another regreadrer has mistakely same ports
Enhance iPerl dialog layout and error handling: improve `ShuffleTextBoxes` with positional mapping, refine checkbox state tracking, add detailed logging for labels and checkboxes, and handle serial port exceptions. Increment version to 3.9.3139.0.
2026-08-18 16:09:21 +02:00
michal f3e5527145 ver. 3.9.3138.0 - OPTHO FORMATING improve (ASIC,genesis) 2026-08-17 10:27:10 +02:00
michal 3488939995 FIX iPerl ASIC meter - mexico
Update MultiplyFactor constant to 1 and increment version to 3.9.3137.0
2026-08-14 14:14:33 +02:00
michal 0f2ef5a5bf bugfix IPERL_ASIC conductivity
update mappings , version 3.9.3136.0
2026-08-13 15:16:58 +02:00
michal 55d2381e8a Mexico - read additional parameters and store to DB, ver. 3.9.3135.0
Add support for reading and handling additional common parameters in OptoHeadTest. Extend RadioService and related classes with enhanced parsing and validation logic. Update UI and constants for functionality integration.
2026-08-12 16:20:16 +02:00
marekf 93d7456ccd <Fix>: RefPulses carry-over by restoring testInProgress behavior in StandingStartMassCollection, increase revision to 3.9.3134.112
Cause:
1. Background: there was a suspicion that the Bukoven board left RefPulses active across operations; this was investigated and ruled out. The pulse counter is reset by testInProgress when an operation is reused. During the third DataEntry window testInProgress had been temporarily disabled (SLM vs Karlsruhe difference), which allowed RefPulses to appear to persist.
2. Increase revision to 3.9.3134.112

Solution:
1. Restore/ensure testInProgress behavior during the DataEntry sequence and explicitly reset the pulse counter when starting a new operation.
2. Increased revision to 3.9.3134.112
2026-08-04 16:21:33 +02:00
marekf 79de40515a Upgrade: Deleted LANG_PL compilation condition, disabled legalizator before test, and version to 3.9.3134.111
Cause:
1. Unnecessary and mandatory user verification before the test, in addition, a bug appears: the "Approval by legalizer" window is displayed behind the main application window. The window was only needed for the Polish project.
2. `LANG_PL` constant in `TBF.csproj` was no longer needed.
3. Assembly version and file version in `AssemblyInfo.cs` needed to be incremented to `3.9.3134.111`.

Solution:
1. Made `altProcNameLabel` and `altProcNameTextBox` always visible and disabled specific UI controls in `ProcedureDlg.cs`.
2. Removed `LANG_PL` from `DefineConstants` in `TBF.csproj`.
3. Updated assembly version and file version in `AssemblyInfo.cs` to `3.9.3134.111`.
2026-07-28 11:49:37 +02:00
marekf e38c6c1199 Upgrade: Add remaining time display for tests, version 3.9.3134.110
Cause:
1. Missing functionality to display remaining time during tests in `StandingStartMassCollectionSeq.cs` and `StandingStartMassCollectionAdvanceSeq.cs`.
2. Assembly version and file version required an update to reflect changes.

Solution:
1. Implemented remaining time display in `StandingStartMassCollectionSeq.cs` and `StandingStartMassCollectionAdvanceSeq.cs` using `Bridge.OnActivity` to show time in minutes and seconds or seconds only.
2. Updated assembly version and file version in `AssemblyInfo.cs` to `3.9.3134.110`.
2026-07-28 11:32:53 +02:00
marekf dbb35a203e Update: Adjust input unit constants in DataEntry form and increment version to 3.9.3134.109
Cause:
1. Updated `unit` constant in `TestStartEndForm` class within `TBF.Rig.DataEntry.StandardCamera` namespace from `Unit.m3` to `Unit.l`.
2. Updated `unit` constant in `TestStartEndForm` class within `TBF.Rig.DataEntry.StandartCameraPurchaseOrder` namespace from `Unit.m3` to `Unit.l`.
3. Incremented assembly version and file version in `AssemblyInfo.cs` to `3.9.3134.109`.

Solution:
1. Changed `unit` constant in `TestStartEndForm` class within `TBF.Rig.DataEntry.StandardCamera` namespace to `Unit.l`.
2. Changed `unit` constant in `TestStartEndForm` class within `TBF.Rig.DataEntry.StandartCameraPurchaseOrder` namespace to `Unit.l`.
3. Updated assembly version and file version in `AssemblyInfo.cs` to `3.9.3134.109`.
2026-07-28 07:38:30 +02:00
marekf a88a094e86 Release SLM-PT50 3.9.3134.108, increase revision after merge 2026-07-23 13:08:52 +02:00
marekf a210a0d1f2 Upgrade (UniDataStorageWriter): improve writer configuration UX and CSV handling
- added technology-specific default configuration for new writers
- auto-fill default SQL/XLSX write templates
- disabled write templates for CSV technology
- added technology-specific data source hints
- changed test parameter format to Column=Value and Where=Value;Set=Value
- improved parameter validation to prevent invalid input crashes
- added automatic CSV header creation and header validation
- aligned CSV writer behaviour with XLSX writer
- Increase revision number
2026-07-21 11:18:11 +02:00
marekf b746ceb34a Upgrade - Replace PulsesTypeByQuantity with MultiFunctionalVariables unit filtering based on RegisterReader quantity type - remove PulsesTypeByQuantity-based parameter values
- generate available units using Units.IsQuantity(...)
- use Quantity.MultiFunctionalVariables to populate supported units
- centralize unit selection through Units.GetQuantity()
2026-07-20 14:09:29 +02:00
marekf 83c1f0e817 Update - Actualized revision nr. 2026-07-17 14:15:22 +02:00
marekf 271200a8da Upgrade - StandingStartMassCollectionAdvance method - 1. changed structure and residual flow delays by changes in StandingStartMassCollection method, 2. added variables, counting and evaluation for volume/mass type of RegisterReader 2026-07-17 12:42:07 +02:00
marekf 637d1d021d Fix - StandingMassCollection method - add end mass measurement 2026-07-16 15:19:28 +02:00
marekf dbe424b17a Add - StandingStart method - Store and log default PumpPower for dynamic test repetitions - Read PumpPower from the current pump before starting dynamic tests.
- Store the value as the default PumpPower for subsequent test instances in the cycle.
- Add logging when PumpPower is initialized from the pump.
- Add logging at test start including test name, repetition number,
  last repetition flag, and PumpPower to improve diagnostics.
2026-07-16 14:21:00 +02:00
marekf be0525a319 Upgrade - improved StandingStart method by SLM requirements, added fixed delays for meters stabilization 2026-07-16 13:29:42 +02:00
michal 28607e2729 fix Strings - Camera CJMS11 - support dialog multi pictures 2026-07-16 12:28:28 +02:00
marekf 0075362f92 Fix - Handle scale underload condition
- Added Underload measurement state
- Detect underload responses from Mettler Toledo scales
- Automatically zero the scale after underload detection
- Restart mass measurement after successful zeroing
- Prevent zeroing response from being used as a valid measurement
- Preserve measurement stability by clearing buffered readings after underload
2026-07-13 14:01:57 +02:00
michal 26b7aa7e8b correction atempt MultiplyFactor for timestamp, volume calculation, 2026-07-02 23:53:15 +02:00
michal 92f63e744d fix INIT - Overload time fix for OptoTelegramRawTest 2026-07-02 23:24:00 +02:00
michal b0581d81ef Extend measurement window for low-flow tests 2026-07-02 23:08:28 +02:00
michal 540b9af871 Overload time fix for OptoTelegramRawTest 2026-07-02 22:32:19 +02:00
michal d11f7107fe fix time calculation from raw data 2026-07-02 21:49:01 +02:00
michal 3c5a28f69d changed LED state from 4 to 7 in 2026-07-02 21:47:14 +02:00
michal 16a76720b8 Update references and paths for Xylem.Common components, refine OptoHeadTest handling for connection requests, and increment assembly version to 3.9.3063.1. 2026-05-05 08:34:21 +02:00
michal 33a5e479a9 Refactor RadioService to improve asynchronous handling, replace legacy code with CommInterfaceBridge, and standardize methods for GenesisHead communication. Remove unused GenesisCommunication components and increment assembly version to 3.9.3062.1. 2026-04-28 16:26:26 +02:00
marekf 38fa86d243 Merge branch 'develop/UnionTown' into develop/SLM-PT50 2026-04-27 16:42:47 +02:00
marekf 6199bd48c5 Upgrade .NET Framework 4.7.2 to 4.8 for Laatzen + GCI + TBF compatibility 2026-04-24 13:00:53 +02:00
michal de6dd45dcb Fix Flow - Increment assembly version to 3.9.3059.1. 2026-04-23 09:56:32 +02:00
michal 842f009b42 Increment assembly version to 3.9.3058.1 and fix logging format issue in FlowMeter initialization. 2026-04-21 07:43:35 +02:00
michal 5a8478e782 Refactor GenesisSmartReader Q3 calibration tests and logic:
- Expand Q3 calibration tests with diverse scenarios in `GenesisSmartReader_Q3Test`.
- Introduce channel-specific validation for calibration tests.
- Adjust methods for Q3 calibration in `GenesisSmartReader` to support per-channel factors.
- Add utilities for preparing simulation data and refinements for test consistency.
- Update `CliRunner` with improved task management, timeout handling, and logging enhancements.