Milan Hanajik
847862a554
Purchase order history in Local settings
2015-03-26 06:38:03 +01:00
Milan Hanajik
0323efe57c
PurchaseOrder handling in database and entry forms. DB table TestResult changed.
...
IHasCycleBeginForm and IHasCycleEndForm changed, values now available directly from forms, not only from Watermeters.
2015-03-26 05:53:15 +01:00
Milan Hanajik
cd1b449585
Metler-Toledo bug fix: When the scale was overloaded, it stopped measuring.
2015-03-25 15:07:39 +01:00
Milan Hanajik
5075bd6068
Regul. valve calibration completed and tested
2015-03-25 13:52:51 +01:00
Milan Hanajik
a26c90f217
Mass values are printed out using format specified by Balance component parameters
2015-03-25 10:01:37 +01:00
Milan Hanajik
4342e7a8b2
Bug fixes in Entry Forms
2015-03-25 07:56:55 +01:00
Milan Hanajik
1e63ded8e1
MetersKind.Standard in TBF/Entities/Enums.cs reverted to MetersKind.Single
2015-03-25 05:35:05 +01:00
Milan Hanajik
23d5e6d19d
Disabled watermeters will not appear in results (screen, ResultsPrinters.Basic and ResultsWriters.Basic).
...
Updating Disabled (default = false) is provided by DataEntry.Standard when entering serial numbers.
2015-03-25 03:57:46 +01:00
Milan Hanajik
7dce565e4f
MetersKind.Single in TBF/Entities/Enuns.cs renamed to MetersKind.Standard
2015-03-25 02:31:28 +01:00
Milan Hanajik
f524186b70
More DataEntry.Standard related changes
2015-03-25 02:14:42 +01:00
Milan Hanajik
dc9577eaa0
Test methods for standard watermeter use IWatermeter.Disabled flag to remove non-existing meter results
2015-03-24 10:11:20 +01:00
Milan Hanajik
d1e9537610
DataEntry.Standard (with checkBoxes) and DataEntry.Combined entry forms added.
...
IWaterMeter.Disabled supported.
2015-03-24 10:09:47 +01:00
Milan Hanajik
2902f36332
Work in progress: Diverter calibration
2015-03-24 02:45:36 +01:00
Milan Hanajik
1c46002aaa
Regulation valve calibration fixed (feedback from ADC)
2015-03-24 02:45:09 +01:00
Milan Hanajik
4dfa98ff89
EtCalib[] array size for Torino corrected, index checked when accessing the array.
2015-03-24 02:44:13 +01:00
Milan Hanajik
6305c42f8b
More program extensions to handle TORINO50 define.
2015-03-09 17:30:38 +01:00
Milan Hanajik
c2bccda07f
Program extensions to handle TORINO50 define.
2015-03-09 15:47:59 +01:00
Milan Hanajik
fb1ddad3b8
One more bug fix in modeless data entry forms.
2015-03-08 15:13:50 +01:00
Milan Hanajik
9e28856229
Bug fixes in modeless data entry forms.
2015-03-08 09:05:40 +01:00
Milan Hanajik
c005a5cb26
Solves issue with an opened CycleBeginForm after abort and re-selection in Israel:
...
- CloseCycleBeginForm() -> WaitBeginFormClosed()
- CloseBeginForm() added to SequenceBase(forced dialog close)
- CloseModellFormHandler added to UiBridge.Bridge
2015-03-01 11:13:26 +01:00
Milan Hanajik
9fa72109da
Fixed bugs:
...
- when there is a configuration error in a test and Data entry form for s/n-s was not closed yet
- when showing results with a combination of different tests
2015-02-21 20:03:33 +01:00
Milan Hanajik
82a72670a6
Remaining time displayed for all tests
2015-02-21 20:03:33 +01:00
Milan Hanajik
08e53c090e
PMaxTest and LeakTest improvements:
...
- result items P_xy_start and P_xy_end added
- DurationLeak test parameter for LeakTest method
- correct default parameters for Danfoss.VLT2800.Pump (FC protocol)
- bug fixes
2015-02-20 13:07:21 +01:00
Milan Hanajik
b07c7c5c9d
PMaxTest and LeakTest methods implemented, added to the project
...
Order of two new test wizard dialog exchanged
Pressure Selection wizard dialog added
2015-02-19 15:54:55 +01:00
Milan Hanajik
93fd6a4f42
Support for FC protocol for Danfoss-VLT2800 and associated valve added - control part
2015-02-18 22:50:44 +01:00
Milan Hanajik
abd636b137
Checksum calculation for telegrams added, Telegram class added
2015-02-18 18:05:32 +01:00
Milan Hanajik
5e4eec4d70
Support for FC protocol for Danfoss-VLT2800 added - UI Part
2015-02-18 16:19:37 +01:00
Milan Hanajik
1dbbe31eae
Bug fix for the case of combined WM test and odd total nr. of watermeters (Munich)
2015-02-18 14:49:19 +01:00
Milan Hanajik
2ca36374e6
Danfoss-VLT2800-Pump functions OK, TODO: control the valve of the pump
2015-02-16 21:01:37 +01:00
Milan Hanajik
50cd1c5d4f
Files for Danfoss-VLT800-Pump added to the repository, builds OK
2015-02-16 13:36:22 +01:00
Milan Hanajik
6eb384283a
Regul. valve calibration uses 2 sec. pulses
2015-02-10 09:01:30 +01:00
Milan Hanajik
558cfb8c6e
Bug fix in saving test results
2015-02-07 21:21:43 +01:00
Milan Hanajik
338a1f2d49
Cycle nr changed to Batch nr in printouts, saved data
2015-02-03 11:08:12 +01:00
Milan Hanajik
64253e1985
(1) RegulValveTandem wont appear in transition sequences, (2) Fixed RegulValveTandem initialization
2015-02-03 10:53:02 +01:00
Milan Hanajik
5806a65a0c
RegulValveTandem op SetFlowOp should be functional, to be tested
2015-02-03 10:30:24 +01:00
Milan Hanajik
ab8aa61a29
Initial version with config UI, w/o functionality, added to the project
2015-02-03 08:06:20 +01:00
Milan Hanajik
0c9408ff64
More configuration checks when starting a test
2015-02-02 23:18:28 +01:00
Milan Hanajik
94aa744fd4
Range of RegulValve indexes changed to 1..8, there are 6 RV-s in Pt200il
2015-02-02 22:49:08 +01:00
Milan Hanajik
9bd5fba6dc
(1) CycleNr renamed to BatchNr (no DB change) and added to results/logs
...
(2) Safer result items
2015-02-02 18:10:52 +01:00
Milan Hanajik
3e48e4c50c
Printed header correctly scaled, bugfix in saving results into DB/Summary
2015-02-02 15:04:48 +01:00
Milan Hanajik
e1756f692c
Confirmed results to SummaryResults.txt logger
2015-02-02 11:38:42 +01:00
Milan Hanajik
376056fb1a
Results to database consolidated, 1-based WMNr used in printing, saving
2015-02-02 10:35:15 +01:00
Milan Hanajik
56a9a7cf1b
Test results are written into database after confirming with END
2015-02-02 00:08:47 +01:00
Milan Hanajik
ce6214f631
Zapne pumpu pred vypustanim aj pri ostatnych metodach
2015-02-01 19:30:00 +01:00
Milan Hanajik
57a7510d05
Center stripe in the Error dialog of the Adjustment method
2015-02-01 19:28:26 +01:00
Milan Hanajik
7e8dfd472d
Zapne pumpu pred vypustanim
2015-02-01 18:53:09 +01:00
Milan Hanajik
6dbff5978a
Pokus
2015-02-01 17:14:50 +01:00
Milan Hanajik
806f4efe6a
Results printing and saving uses Publish property of GenericDevices.ITestMethod
2015-02-01 16:20:27 +01:00
Milan Hanajik
0238a96975
More comments in SetFlowOp
2015-02-01 15:07:15 +01:00
Milan Hanajik
ae5abde1e6
Results printing and saving improced, correct order of tests, etc.
2015-02-01 13:43:04 +01:00